Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri
Abstract
THE RELIABILITY OF THE TAP TEST AT THE PREDICTION OF FETAL PULMONARY MATURITY
✓ It has been reported that the tap test is reliable and a rapid indicator of fetal pulmonary ma¬turity. In this study, we investigated the reliability of the tap test to determine fetal pulmonary maturity in term and preterm deliveries. We found out that the tap test was a reliabl test with a sensitivity of 75%, specificity of 100 %, positive predictive value of 100% and a negative predicti¬ve value of 82% in preterm deliveries. In term deliveries, the test had sensitivity of 92%, specifi¬city of 100%, positive predictive value of 100% and negative predictive value of 17% . We conc¬luded that the tap test could be routinely used as a rapid indicator of fetal pulmonary maturity.
Tap testinin fetal pulmoner maturité tayininde güvenilir ve hızlı bir test olduğu rapor edil-miştir. Çalışmamızda, matür ve prematür doğumlarda, tap testinin pulmoner maturité tayinindeki güvenirliliğini araştırdık. Prematür doğumlarda nRDS yi saptamada, metodunsensitivitesini % 75, spesifisitesini % 100, pozitif prediktif değerini % 100, negatif prediktif değerini % 82 olarak bulduk. Matür doğumlarda testin sensitivitesi % 92,spesifisitesi % 100, pozitif prediktif değeri % 100, negatif prediktif değeri % 17 idi.Tap testinin fetal pulmoner maturité tayini için rutin olarak kullanılabilecek bir test olduğu sonucuna vardık.
Keywords
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
December 22, 2009
Submission Date
November 23, 2009
Acceptance Date
-
Published in Issue
Year 1992 Volume: 9 Number: 2
APA
Malatyalıoğlu, E., Kökçü, A., Alper, T., & Çokşenim, Ş. (2009). Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. Deneysel Ve Klinik Tıp Dergisi, 9(2). https://doi.org/10.5835/jecm.v9i2.403
AMA
1.Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. 2009;9(2). doi:10.5835/jecm.v9i2.403
Chicago
Malatyalıoğlu, E., A. Kökçü, T. Alper, and Ş. Çokşenim. 2009. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Deneysel Ve Klinik Tıp Dergisi 9 (2). https://doi.org/10.5835/jecm.v9i2.403.
EndNote
Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş (December 1, 2009) Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. Deneysel ve Klinik Tıp Dergisi 9 2
IEEE
[1]E. Malatyalıoğlu, A. Kökçü, T. Alper, and Ş. Çokşenim, “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”, J. Exp. Clin. Med., vol. 9, no. 2, Dec. 2009, doi: 10.5835/jecm.v9i2.403.
ISNAD
Malatyalıoğlu, E. - Kökçü, A. - Alper, T. - Çokşenim, Ş. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Deneysel ve Klinik Tıp Dergisi 9/2 (December 1, 2009). https://doi.org/10.5835/jecm.v9i2.403.
JAMA
1.Malatyalıoğlu E, Kökçü A, Alper T, Çokşenim Ş. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. 2009;9. doi:10.5835/jecm.v9i2.403.
MLA
Malatyalıoğlu, E., et al. “Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri”. Deneysel Ve Klinik Tıp Dergisi, vol. 9, no. 2, Dec. 2009, doi:10.5835/jecm.v9i2.403.
Vancouver
1.E. Malatyalıoğlu, A. Kökçü, T. Alper, Ş. Çokşenim. Fetal Pulmoner Matürityi Saptamada Tap Testinin Değeri. J. Exp. Clin. Med. 2009 Dec. 1;9(2). doi:10.5835/jecm.v9i2.403