Abstract

Heart volume along with dose volume histograms are essential in reducing pulmonary and cardiac complications. The aim of this study is to measure the ventricular volume using computerized tomography (CT) and magnetic resonance imaging (MRI), to detect the differences between the two scans and to investigate whether the estimated volumes concur with the actual volume of the hearts obtained by the fluid displacement technique. The present study were performed in six heart sheep. Hearts were scanned in the horizontal plane using CT (Toshiba, Aquilion, Japan) and MR machine (Siemens 1.5T Avanto, Germany), we decided for 1 mm as sample thickness fraction for both MR and CT images.The images were analyzed using Image software. Planimetry and threshold stereological methods were applied to estimate the ventricular volume. To evaluate the accuracy of two scans, all the estimates were done by the same observer. The actual hearts mean volumes were 109.38 cm3±17.77. The mean volume of the hearts in CT images of different thickness (0.94, 1.94, 2.94, 3.94 and 4.94 mm) were 110.34 cm3±17.63, 110.61 cm3±17.70, 111.03 cm3±17.65, 111.48 cm3±17.68 and 112.18 cm3±17.86, respectively. The mean volume of the hearts in MRI of different thickness (1.1, 2.1, 3.1, 4.1 and 5.1 mm) were 103.78 cm3±17.60, 104.12 cm3±17.91, 104.31 cm3±17.89, 104.41 cm3±17.84 and 104.56 cm3±17.95, respectively. There were significant statistical difference between the mean volume of the actual hearts and mean volume of the hearts in CT and MRI (p<0.05). CT and MRI datasets allowed an interchangeable utilization of volumetric analysis tools, MRI demonstrated a significant reduction in the ventricular volume, while CT provides accurate volumetric information of the ventricles in comparison withactual hearts volume. However, reliable volumetric analysis was limited to an optimal range of cardiac rates for each modality.

Year 2014, Volume: 31 Issue: 2, 0 - , 10.09.2014
https://izlik.org/JA58SA39YM

Abstract

There are 0 citations in total.

Details

Primary Language English
Authors

Fikri Ozdemır

Micheal Mazonakıs This is me

Bunyamin Sahın This is me

Amani Elfakı This is me

Ozcan Yılmaz This is me

Mustafa Bekir Selcuk This is me

Submission Date September 10, 2014
Publication Date September 10, 2014
DOI https://doi.org/10.5835/jecm.v2i31.5000068757
IZ https://izlik.org/JA58SA39YM
Published in Issue Year 2014 Volume: 31 Issue: 2

Cite

APA Ozdemır, F., Mazonakıs, M., Sahın, B., Elfakı, A., Yılmaz, O., & Selcuk, M. B. (2014). Assesment of the heart volume using computerized tomography and magnetic resonance imaging. Deneysel Ve Klinik Tıp Dergisi, 31(2). https://doi.org/10.5835/jecm.v2i31.5000068757
AMA 1.Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. 2014;31(2). doi:10.5835/jecm.v2i31.5000068757
Chicago Ozdemır, Fikri, Micheal Mazonakıs, Bunyamin Sahın, Amani Elfakı, Ozcan Yılmaz, and Mustafa Bekir Selcuk. 2014. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Deneysel Ve Klinik Tıp Dergisi 31 (2). https://doi.org/10.5835/jecm.v2i31.5000068757.
EndNote Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB (September 1, 2014) Assesment of the heart volume using computerized tomography and magnetic resonance imaging. Deneysel ve Klinik Tıp Dergisi 31 2
IEEE [1]F. Ozdemır, M. Mazonakıs, B. Sahın, A. Elfakı, O. Yılmaz, and M. B. Selcuk, “Assesment of the heart volume using computerized tomography and magnetic resonance imaging”, J. Exp. Clin. Med., vol. 31, no. 2, Sept. 2014, doi: 10.5835/jecm.v2i31.5000068757.
ISNAD Ozdemır, Fikri - Mazonakıs, Micheal - Sahın, Bunyamin - Elfakı, Amani - Yılmaz, Ozcan - Selcuk, Mustafa Bekir. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Deneysel ve Klinik Tıp Dergisi 31/2 (September 1, 2014). https://doi.org/10.5835/jecm.v2i31.5000068757.
JAMA 1.Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. 2014;31. doi:10.5835/jecm.v2i31.5000068757.
MLA Ozdemır, Fikri, et al. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Deneysel Ve Klinik Tıp Dergisi, vol. 31, no. 2, Sept. 2014, doi:10.5835/jecm.v2i31.5000068757.
Vancouver 1.Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. [Internet]. 2014 Sept. 1;31(2). Available from: https://izlik.org/JA58SA39YM