Assesment of the heart volume using computerized tomography and magnetic resonance imaging

Abstract

Heart volume along with dose volume histograms are essential in reducing pulmonary and cardiac complications. The aim of this study is to measure the ventricular volume using computerized tomography (CT) and magnetic resonance imaging (MRI), to detect the differences between the two scans and to investigate whether the estimated volumes concur with the actual volume of the hearts obtained by the fluid displacement technique. The present study were performed in six heart sheep. Hearts were scanned in the horizontal plane using CT (Toshiba, Aquilion, Japan) and MR machine (Siemens 1.5T Avanto, Germany), we decided for 1 mm as sample thickness fraction for both MR and CT images.The images were analyzed using Image software. Planimetry and threshold stereological methods were applied to estimate the ventricular volume. To evaluate the accuracy of two scans, all the estimates were done by the same observer. The actual hearts mean volumes were 109.38 cm3±17.77. The mean volume of the hearts in CT images of different thickness (0.94, 1.94, 2.94, 3.94 and 4.94 mm) were 110.34 cm3±17.63, 110.61 cm3±17.70, 111.03 cm3±17.65, 111.48 cm3±17.68 and 112.18 cm3±17.86, respectively. The mean volume of the hearts in MRI of different thickness (1.1, 2.1, 3.1, 4.1 and 5.1 mm) were 103.78 cm3±17.60, 104.12 cm3±17.91, 104.31 cm3±17.89, 104.41 cm3±17.84 and 104.56 cm3±17.95, respectively. There were significant statistical difference between the mean volume of the actual hearts and mean volume of the hearts in CT and MRI (p<0.05). CT and MRI datasets allowed an interchangeable utilization of volumetric analysis tools, MRI demonstrated a significant reduction in the ventricular volume, while CT provides accurate volumetric information of the ventricles in comparison withactual hearts volume. However, reliable volumetric analysis was limited to an optimal range of cardiac rates for each modality.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Micheal Mazonakıs This is me

Bunyamin Sahın This is me

Amani Elfakı This is me

Ozcan Yılmaz This is me

Mustafa Bekir Selcuk This is me

Publication Date

September 10, 2014

Submission Date

September 10, 2014

Acceptance Date

-

Published in Issue

Year 2014 Volume: 31 Number: 2

APA
Ozdemır, F., Mazonakıs, M., Sahın, B., Elfakı, A., Yılmaz, O., & Selcuk, M. B. (2014). Assesment of the heart volume using computerized tomography and magnetic resonance imaging. Deneysel Ve Klinik Tıp Dergisi, 31(2). https://doi.org/10.5835/jecm.v2i31.5000068757
AMA
1.Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. 2014;31(2). doi:10.5835/jecm.v2i31.5000068757
Chicago
Ozdemır, Fikri, Micheal Mazonakıs, Bunyamin Sahın, Amani Elfakı, Ozcan Yılmaz, and Mustafa Bekir Selcuk. 2014. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Deneysel Ve Klinik Tıp Dergisi 31 (2). https://doi.org/10.5835/jecm.v2i31.5000068757.
EndNote
Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB (September 1, 2014) Assesment of the heart volume using computerized tomography and magnetic resonance imaging. Deneysel ve Klinik Tıp Dergisi 31 2
IEEE
[1]F. Ozdemır, M. Mazonakıs, B. Sahın, A. Elfakı, O. Yılmaz, and M. B. Selcuk, “Assesment of the heart volume using computerized tomography and magnetic resonance imaging”, J. Exp. Clin. Med., vol. 31, no. 2, Sept. 2014, doi: 10.5835/jecm.v2i31.5000068757.
ISNAD
Ozdemır, Fikri - Mazonakıs, Micheal - Sahın, Bunyamin - Elfakı, Amani - Yılmaz, Ozcan - Selcuk, Mustafa Bekir. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Deneysel ve Klinik Tıp Dergisi 31/2 (September 1, 2014). https://doi.org/10.5835/jecm.v2i31.5000068757.
JAMA
1.Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. 2014;31. doi:10.5835/jecm.v2i31.5000068757.
MLA
Ozdemır, Fikri, et al. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Deneysel Ve Klinik Tıp Dergisi, vol. 31, no. 2, Sept. 2014, doi:10.5835/jecm.v2i31.5000068757.
Vancouver
1.Fikri Ozdemır, Micheal Mazonakıs, Bunyamin Sahın, Amani Elfakı, Ozcan Yılmaz, Mustafa Bekir Selcuk. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. 2014 Sep. 1;31(2). doi:10.5835/jecm.v2i31.5000068757