Research Article
BibTex RIS Cite

CFD ANALYSIS OF MINI VENTURI-TYPE AIR FLOWMETERS FOR LAB-SCALE APPLICATIONS

Year 2020, Volume: 38 Issue: 2, 603 - 612, 01.06.2021

Abstract

Being one of the cheapest devices for air flow measurement within a wide range of flowrates, Venturi-type air flowmeters (VTAFs) can also be used for measuring very small air flowrates, usually less than 50 to 100 liters per minute, which is usually encountered in lab-scale applications. This study presents a model-based evaluation of VTAFs for lab-scale applications. The pressure and velocity fields in mini VTAFs were calculated by computational fluid dynamics (CFD) model using Ansys Fluent™. Results showed that sensitive and accurate measurements of volumetric flowrate can be achieved using mini VTAFs. A diameter ratio of 0.6 for the venturi throat provides a minimum detection limit of 2.46 LPM while an overall pressure drop of around 115 Pa at an air flowrate of 50 LPM at 20°C.

References

  • [1] Kumar P., San S.M., “CFD Study of the Effect of Venturi Convergent and Divergent Angles on Low Pressure Wet Gas Metering”, J. Appl. Sci., 14, 3036-3045, 2014.
  • [2] Zhang F., Dong F., Tan C., “High GVF and low pressure gas-liquid two-phase flow measurement based on dual-cone flowmeter”, Flow Meas. Instrum. 21, 410-417, 2010.
  • [3] Demir S., “A Practical Model for Estimating Pressure Drop in Cyclone Separators: An Experimental Study”, Powder Technol. 268, 329-338, 2014.
  • [4] Demir S., Karadeniz A., Aksel, M., “Effects of cylindrical and conical heights on pressure and velocity fields in cyclones”, Powder Technol., 295, 209-217, 2016
  • [5] Demir S., Karadeniz A., Manav Demir N., Duman S., “Excel VBA-Based Solution to Pipe Flow Measurement Problem”, eJSIE, 10(3), 1, 2018.
  • [6] Huang X., van Sciver S.W., “Performance of a Venturi Flow Meter in Two-Phase Helium Flow”, Cryogenics, 36, 303-309, 1996.
  • [7] Steven R., “Wet Gas Metering with a Horizontally Mounted Venturi Meter”, Flow Meas. Instrum., 12, 361-372, 2002.
  • [8] Lide F., Tao Z., Ningde J., 2007, “A Comparison of Correlations Used for Venturi Wet Gas Metering in Oil and Gas Industry”, Journal of Petroleum Science and Engineering, 57, 247-256, 2007.
  • [9] Steven R., “A Dimensional Analysis of Two Phase Flow Through a Horizontall Installed Venturi Flow Meter”, Flow Meas. Instrum., 19, 342-349, 2008.
  • [10] Steven R., Hall A., “Orifica Plate Meter Wet Gas Flow Performance”, Flow Meas. Instrum., 20, 141-151, 2009.
  • [11] Kumar P., Bing M.W.M., “A CFD Study of Low Pressure Wet Gas Metering Using Slotted Orifice Meters”, Flow Meas. Instrum., 22, 33-42, 2011.
  • [12] He D., Bai B., “A New Correlation for Wet Gas Flow Rate Measurement with Venturi Meter Based on Two-Phase Mass Flow Coefficient”, Measurement, 58, 61-67, 2014.
  • [13] Monni G., de Salve M., Panella B., “Two_phase Flow Measurements at High Void Fraction by a Venturi Meter”, Progress in Nuclear Energy 77, 167-175, 2014.
  • [14] Gajan P., Decaudin Q., Couput J.P., “Analysis of High Pressure Tests on Wet Gas Flow Meterin with a Venturi Meter”, Flow Meas. Instrum. 44, 126-131, 2015.
  • [15] Xu Y., Zhang Q., Zhang T., Ba X., “An Overreading Model for Nonstandard Venturi Meters Based on H Correction Factor”, Measurement, 61, 100-106, 2015.
  • [16] Pan Y., Hong Y., Sun Q., Zheng Z., Wang D., Niu P., “A New Correlation of Wet Gas Flow for Low Pressure with a Vertically Mounted Venturi Meter”, Flow Meas. Instrum., 70, 101636, 2019.
There are 16 citations in total.

Details

Primary Language English
Subjects Engineering
Journal Section Research Articles
Authors

Selami Demir This is me 0000-0002-8672-9817

Publication Date June 1, 2021
Submission Date January 23, 2020
Published in Issue Year 2020 Volume: 38 Issue: 2

Cite

Vancouver Demir S. CFD ANALYSIS OF MINI VENTURI-TYPE AIR FLOWMETERS FOR LAB-SCALE APPLICATIONS. SIGMA. 2021;38(2):603-12.

IMPORTANT NOTE: JOURNAL SUBMISSION LINK https://eds.yildiz.edu.tr/sigma/