BibTex RIS Cite

-

Year 2011, Volume: 22 Issue: 107, 5449 - 5462, 01.12.2011
https://izlik.org/JA52UT54WB

Abstract

References

  • Yang, D., Park S., Neale, W.K., “Flexural Behaviour of Reinforced Concrete Beams Strengthened with Prestressed Carbon Composites,” Composite Structures, 88, 2009, pp. 497–508.
  • Mukherjee, A., Rai, L.G., “Performance of Reinforced Concrete Beams Externally Prestressed with Fiber Composites,” Construction and Building Materials, 23, 2009, pp. 822–828.
  • Li, L. J., Guo, Y. C., Liu, F., Bungey, J.H., “Test Analysis for FRC Beams Strengthened with Externally Bonded FRP Sheets,” Construction and Building Materials, 23, 2008, pp. 315–323.
  • Bank, L. C., Arora, D., “Analysis of RC Beams Strengthened with Mechanically Fastened FRP (MF-FRP) Strips,” Composite Structures, 79, 2007, pp. 180–191.
  • Toutanji, H., Zhao, L., Zhang, Y., “Flexural Behavior of Reinforced Concrete Beams Externally Strengthened with CFRP Sheets Bonded with an Inorganic Matrix,” Engineering Structures, 28, 2006, pp. 557–566.
  • Anania, L., Badala, A., Failla, G., “Increasing The Flexural Performance of RC Beams Strengthened with CFRP Materials,” Construction and Building Materials, 19, 2005, pp. 55–61
  • Turkish Institute of Standards, “Requirements for Design and Construction of Reinforced Concrete Structures (TS500-02),” Turkish Standards, 2002, pp. 12, 24, 25, 63–64.
  • ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318- 05) and Commentary (ACI 318R-05),” American Concrete Institute, 20, 2005, pp. 111–112.

BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER

Year 2011, Volume: 22 Issue: 107, 5449 - 5462, 01.12.2011
https://izlik.org/JA52UT54WB

Abstract

Betonarme yapılarda, zemin kattan sonra kat alanını büyütmek amacıyla yapının bir kısmının konsol kirişler üzerine oturtulması özellikle ülkemizde çok sık rastlanılan bir uygulamadır. Bu tür binaların birçoğunda en alt kat konsol kirişleri üzerinde bulunan dolgu duvarlarda zaman içinde değişik boyutlarda çatlaklar oluşabilmektedir. Bu çalışmada, oluşan bu çatlakların nedenleri araştırılmış ve konsollarda oluşan çatlakların nedenlerinden birinin de dolgu duvarlar aracılığı ile üst katlardaki konsol kirişlerden alt katlardaki konsol kirişlere iletilen fazladan yüklerin olduğu deneysel olarak ortaya konmuştur. Çalışmanın sonunda bir üst kattaki konsol kiriş yüklerinin yaklaşık %25 inin dolgu duvarlar aracılığı ile aşağıdaki konsol kirişe aktarıldığı ortaya koyulmuş ve uygulama için yararlı önerilerde bulunulmuştur

References

  • Yang, D., Park S., Neale, W.K., “Flexural Behaviour of Reinforced Concrete Beams Strengthened with Prestressed Carbon Composites,” Composite Structures, 88, 2009, pp. 497–508.
  • Mukherjee, A., Rai, L.G., “Performance of Reinforced Concrete Beams Externally Prestressed with Fiber Composites,” Construction and Building Materials, 23, 2009, pp. 822–828.
  • Li, L. J., Guo, Y. C., Liu, F., Bungey, J.H., “Test Analysis for FRC Beams Strengthened with Externally Bonded FRP Sheets,” Construction and Building Materials, 23, 2008, pp. 315–323.
  • Bank, L. C., Arora, D., “Analysis of RC Beams Strengthened with Mechanically Fastened FRP (MF-FRP) Strips,” Composite Structures, 79, 2007, pp. 180–191.
  • Toutanji, H., Zhao, L., Zhang, Y., “Flexural Behavior of Reinforced Concrete Beams Externally Strengthened with CFRP Sheets Bonded with an Inorganic Matrix,” Engineering Structures, 28, 2006, pp. 557–566.
  • Anania, L., Badala, A., Failla, G., “Increasing The Flexural Performance of RC Beams Strengthened with CFRP Materials,” Construction and Building Materials, 19, 2005, pp. 55–61
  • Turkish Institute of Standards, “Requirements for Design and Construction of Reinforced Concrete Structures (TS500-02),” Turkish Standards, 2002, pp. 12, 24, 25, 63–64.
  • ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318- 05) and Commentary (ACI 318R-05),” American Concrete Institute, 20, 2005, pp. 111–112.
There are 8 citations in total.

Details

Primary Language Turkish
Authors

Sabahattin Aykaç This is me

Submission Date June 18, 2015
Publication Date December 1, 2011
IZ https://izlik.org/JA52UT54WB
Published in Issue Year 2011 Volume: 22 Issue: 107

Cite

APA Aykaç, S. (2011). BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER. Teknik Dergi, 22(107), 5449-5462. https://izlik.org/JA52UT54WB
AMA 1.Aykaç S. BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER. Teknik Dergi. 2011;22(107):5449-5462. https://izlik.org/JA52UT54WB
Chicago Aykaç, Sabahattin. 2011. “BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER”. Teknik Dergi 22 (107): 5449-62. https://izlik.org/JA52UT54WB.
EndNote Aykaç S (December 1, 2011) BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER. Teknik Dergi 22 107 5449–5462.
IEEE [1]S. Aykaç, “BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER”, Teknik Dergi, vol. 22, no. 107, pp. 5449–5462, Dec. 2011, [Online]. Available: https://izlik.org/JA52UT54WB
ISNAD Aykaç, Sabahattin. “BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER”. Teknik Dergi 22/107 (December 1, 2011): 5449-5462. https://izlik.org/JA52UT54WB.
JAMA 1.Aykaç S. BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER. Teknik Dergi. 2011;22:5449–5462.
MLA Aykaç, Sabahattin. “BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER”. Teknik Dergi, vol. 22, no. 107, Dec. 2011, pp. 5449-62, https://izlik.org/JA52UT54WB.
Vancouver 1.Sabahattin Aykaç. BA YAPILARDA KONSOL KİRİŞLERE AKTARILAN İLAVE YÜKLER. Teknik Dergi [Internet]. 2011 Dec. 1;22(107):5449-62. Available from: https://izlik.org/JA52UT54WB