Research Article
BibTex RIS Cite

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns

Year 2010, Volume: 21 Issue: 105, 1425 - 1444, 01.10.2010

Abstract

Increasing the deformation capacities of code-incompliant RC columns by wrapping their potential plastic hinge regions with fiber-reinforced polymer (FRP) has become a rather popular strengthening technique in recent years. FRP design guidelines are included in the 7th chapter of the Turkish Earthquake Code (TEC-07) that became effective in 2007. This study intends to scrutinize the design approach of TEC-07 in light of the test results of 10 columns tested under axial load and cyclic displacement excursions at METU and the test results of 18 columns gathered from literature. After careful investigations, it was clearly seen that in TEC-07, the FRP wrapped column performance limits were over conservative and led to uneconomical designs. Two different design methods were developed. The first one is compatible with the current code procedure and the other is based on interstory drifts in order to obtain simpler and more economical FRP design in addition to its accuracy. 

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns

Year 2010, Volume: 21 Issue: 105, 1425 - 1444, 01.10.2010

Abstract

-

There are 0 citations in total.

Details

Primary Language English
Subjects Engineering
Journal Section Articles
Authors

Okan Özcan This is me

Barış Binici This is me

Güney Özcebe This is me

Publication Date October 1, 2010
Submission Date June 18, 2015
Published in Issue Year 2010 Volume: 21 Issue: 105

Cite

APA Özcan, O., Binici, B., & Özcebe, G. (2010). Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi, 21(105), 1425-1444.
AMA Özcan O, Binici B, Özcebe G. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi. October 2010;21(105):1425-1444.
Chicago Özcan, Okan, Barış Binici, and Güney Özcebe. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi 21, no. 105 (October 2010): 1425-44.
EndNote Özcan O, Binici B, Özcebe G (October 1, 2010) Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi 21 105 1425–1444.
IEEE O. Özcan, B. Binici, and G. Özcebe, “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”, Teknik Dergi, vol. 21, no. 105, pp. 1425–1444, 2010.
ISNAD Özcan, Okan et al. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi 21/105 (October 2010), 1425-1444.
JAMA Özcan O, Binici B, Özcebe G. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi. 2010;21:1425–1444.
MLA Özcan, Okan et al. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi, vol. 21, no. 105, 2010, pp. 1425-44.
Vancouver Özcan O, Binici B, Özcebe G. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi. 2010;21(105):1425-44.