Note

DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION

Volume: 5 Number: 1 October 3, 2018
  • Avinash Deshmukh
EN

DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION

Abstract

In today's essential commodities, air conditioning system is one of the major energy consuming elements. Nowadays evaporative cooling systems are mostly preferred as an alternative to compressor-based air conditioned systems. It is reported that evaporative cooling systems consume 60 - 70 % less energy compared to compressor-based air conditioning systems. In this paper, performance analysis of a mist evaporative cooler is carried out experimentally. The performance parameters such as, drop in temperature, cooling capacity, saturation efficiency, the coefficient of performance are evaluated with respect to various ambient conditions and with a varied mass flow rate of air. Experimental data used to develop an empirical correlation to predict the temperature of cooled air by linear regression analysis. Predicted temperature of cooled air temperature by empirical correlation is validated through experimentation, and are good in agreement with experimental values.

Keywords

References

  1. [1] Kovačević, I., Sourbron, M. (2017). The numerical model for direct evaporative cooler. Applied Thermal Engineering, 113, 8-19.
  2. [2] Wu, J. M., Huang, X., Zhang, H. (2009). Theoretical analysis on heat and mass transfer in a direct evaporative cooler. Applied Thermal Engineering, 29(5-6), 980-984.
  3. [3]Sheng, C., & Nnanna, A. A. (2011, January). Empirical correlation of cooling efficiency and transport phenomena of direct evaporative cooler. In ASME 2011 International Mechanical Engineering Congress and Exposition (pp. 953-967). American Society of Mechanical Engineers.
  4. [4] Khater, E. S. G. (2014). Performance of Direct Evaporative Cooling System under Egyptian Conditions. Journal of Climatology & Weather Forecasting, 2.
  5. [5] Riangvilaikul, B., Kumar, S. (2010). An experimental study of a novel dew point evaporative cooling system. Energy and Buildings, 42(5), 637-644.
  6. [6] Zhou, K. (2014). Calculation of Evaporation Rate of a Droplets Cluster and Conceptual Design of a Structure Utilizing Water Droplets for Evaporation. Hydrology: Current Research, 5(3), 1.
  7. [7] Chakrabarti, S. S., Bhandarkar, L. R., Vijawargiya, A., Nageshwar Rao, P. S. R. K. (2015). A mathematical approach in the formulation of a direct evaporative cooling device, International Journal of Engineering Research & Technology (IJERT), 4, 02.
  8. [8] Farnham, C., Zhang, L., Yuan, J., Emura, K., Alam, A. M., Mizuno, T. (2017). Measurement of the evaporative cooling effect: oscillating misting fan. Building Research & Information, 45(7), 783-799.

Details

Primary Language

English

Subjects

-

Journal Section

Note

Authors

Avinash Deshmukh This is me

Publication Date

October 3, 2018

Submission Date

April 18, 2018

Acceptance Date

June 18, 2018

Published in Issue

Year 2019 Volume: 5 Number: 1

APA
Deshmukh, A. (2018). DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION. Journal of Thermal Engineering, 5(1), 42-50. https://doi.org/10.18186/thermal.513053
AMA
1.Deshmukh A. DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION. Journal of Thermal Engineering. 2018;5(1):42-50. doi:10.18186/thermal.513053
Chicago
Deshmukh, Avinash. 2018. “DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION”. Journal of Thermal Engineering 5 (1): 42-50. https://doi.org/10.18186/thermal.513053.
EndNote
Deshmukh A (October 1, 2018) DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION. Journal of Thermal Engineering 5 1 42–50.
IEEE
[1]A. Deshmukh, “DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION”, Journal of Thermal Engineering, vol. 5, no. 1, pp. 42–50, Oct. 2018, doi: 10.18186/thermal.513053.
ISNAD
Deshmukh, Avinash. “DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION”. Journal of Thermal Engineering 5/1 (October 1, 2018): 42-50. https://doi.org/10.18186/thermal.513053.
JAMA
1.Deshmukh A. DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION. Journal of Thermal Engineering. 2018;5:42–50.
MLA
Deshmukh, Avinash. “DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION”. Journal of Thermal Engineering, vol. 5, no. 1, Oct. 2018, pp. 42-50, doi:10.18186/thermal.513053.
Vancouver
1.Avinash Deshmukh. DESIGN, DEVELOPMENT AND FABRICATION OF A MIST SPRAY DIRECT EVAPORATIVE COOLING SYSTEM AND ITS PERFORMANCE EVALUATION. Journal of Thermal Engineering. 2018 Oct. 1;5(1):42-50. doi:10.18186/thermal.513053

Cited By

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering