Research Article

THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS

Volume: 5 Number: 3 March 14, 2019
  • Bahri Aksu
EN

THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS

Abstract

A thermoeconomic analysis of a water to water heat pump are performed under different condenser and evaporator conditions. Experiments are realized for different volumetric   inlet temperatures of 14.4, 17 and 19  and different volumetric flow rates of 50, 100, 150 lt/h for condenser cooling water. Same inlet temperatures with condenser cooling water are used for evaporator water inlet, while constant volumetric flow rate of 100 lt/h is used for each case. Modified Productive Structure Analysis (MOPSA) is used for thermoeconomic analysis. It is found that increases in inlet temperature and in volumetric flow rate cause to decrease in both the unit cost of heat delivered ( ) and the unit cost of entropy generation ( ). As a result, in the case of =14.4 and = 50 lt/h,  and values are obtained to be 0.0489 $/kWh and 0.0221 $/kWh, respectively, while  and values are obtained to be 0.0385 $/kWh and 0.0175 $/kWh for =19 and = 150 lt/h, respectively.

Keywords

References

  1. [1] Waheed, M. A., Oni, A. O., Adejuyigbe, S. B., Adewumi, B. A., Fadare, D. A. (2014). Performance enhancement of vapor recompression heat pump. Applied energy, 114, 69-79.
  2. [2] Qureshi, B. A., Zubair, S. M. (2013). Cost optimization of heat exchanger inventory for mechanical subcooling refrigeration cycles. International Journal of Refrigeration, 36(4), 1243-1253.
  3. [3] Kodal, A., Sahin, B., Ekmekci, I., Yilmaz, T. (2003). Thermoeconomic optimization for irreversible absorption refrigerators and heat pumps. Energy Conversion and Management, 44(1), 109-123.
  4. [4] Kodal, A., Sahin, B., Yilmaz, T. (2000). Effects of internal irreversibility and heat leakage on the finite time thermoeconomic performance of refrigerators and heat pumps. Energy Conversion and Management, 41(6), 607-619.
  5. [5] Teyber, R., Trevizoli, P. V., Christiaanse, T. V., Govindappa, P., Niknia, I., Rowe, A. (2017). Permanent magnet design for magnetic heat pumps using total cost minimization. Journal of Magnetism and Magnetic Materials, 442, 87-96.
  6. [6] Esfahani, I. J., Yoo, C. (2014). A highly efficient combined multi-effect evaporation-absorption heat pump and vapor-compression refrigeration part 2: Thermoeconomic and flexibility analysis. Energy, 75, 327-337.
  7. [7] Verda, V., Caccin, M., Kona, A. (2016). Thermoeconomic cost assessment in future district heating networks. Energy, 117, 485-491.
  8. [8] Arat, H., Arslan, O. (2017). Exergoeconomic analysis of district heating system boosted by the geothermal heat pump. Energy, 119, 1159-1170.

Details

Primary Language

English

Subjects

-

Journal Section

Research Article

Authors

Bahri Aksu This is me

Publication Date

March 14, 2019

Submission Date

December 19, 2017

Acceptance Date

March 14, 2018

Published in Issue

Year 2019 Volume: 5 Number: 3

APA
Aksu, B. (2019). THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS. Journal of Thermal Engineering, 5(3), 198-209. https://doi.org/10.18186/thermal.541078
AMA
1.Aksu B. THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS. Journal of Thermal Engineering. 2019;5(3):198-209. doi:10.18186/thermal.541078
Chicago
Aksu, Bahri. 2019. “THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS”. Journal of Thermal Engineering 5 (3): 198-209. https://doi.org/10.18186/thermal.541078.
EndNote
Aksu B (March 1, 2019) THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS. Journal of Thermal Engineering 5 3 198–209.
IEEE
[1]B. Aksu, “THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS”, Journal of Thermal Engineering, vol. 5, no. 3, pp. 198–209, Mar. 2019, doi: 10.18186/thermal.541078.
ISNAD
Aksu, Bahri. “THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS”. Journal of Thermal Engineering 5/3 (March 1, 2019): 198-209. https://doi.org/10.18186/thermal.541078.
JAMA
1.Aksu B. THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS. Journal of Thermal Engineering. 2019;5:198–209.
MLA
Aksu, Bahri. “THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS”. Journal of Thermal Engineering, vol. 5, no. 3, Mar. 2019, pp. 198-09, doi:10.18186/thermal.541078.
Vancouver
1.Bahri Aksu. THERMOECONOMIC ANALYSIS OF A WATER TO WATER HEAT PUMP UNDER DIFFERENT CONDENSER AND EVAPORATOR CONDITIONS. Journal of Thermal Engineering. 2019 Mar. 1;5(3):198-209. doi:10.18186/thermal.541078

Cited By

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering