INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290

Abstract

This paper investigates a modified ejector cycle (MEC) to further enhance the COP improvement of residential air conditioner (A/C), as compared to the standard ejector cycle (SEC). This paper also presents numerical and experimental studies of the MEC. Numerical approach of MEC performances was evaluated by using SEC cycle that had been developed by many researchers. In the experimental study of MEC, three motive nozzle diameters of 0.9, 1.0 and 1.1 mm were utilized. In addition, environmentally friendly refrigerant of R290 (propane) was used as a working fluid. The modeling results of residential A/C with the cooling capacity of 2.5 kW showed higher COP improvements of MEC than SEC for all entrainment ratios of the ejector. There was no COP improvement for SEC at a low entrainment ratio, whereas there are always COP improvements for all entrainment ratios for MEC. In addition, the experimental results showed the highest COP improvement of 16.67% was achieved with the motive nozzle diameter of 1.1 mm.

Keywords

References

  1. [1] Chang YS, Kim MS, Ro ST. Performance and heat transfer characteristics of hydrocarbon refrigerants in a heat pump system. International Journal of Refrigeration. 2000;23(3):232-42. doi:10.1016/s0140-7007(99)00042-0.
  2. [2] Devotta S, Padalkar AS, Sane NK. Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner. International Journal of Refrigeration. 2005;28(4):594-604. doi:10.1016/j.ijrefrig.2004.09.013.
  3. [3] Zhou G, Zhang Y. Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290. Applied Energy. 2010;87(5):1522-8. doi:10.1016/j.apenergy.2009.10.005.
  4. [4] Padilla M, Revellin R, Bonjour J. Exergy analysis of R413A as replacement of R12 in a domestic refrigeration system. Energy Conversion and Management. 2010;51(11):2195-201. doi:10.1016/j.enconman.2010.03.013.
  5. [5] Sukri MF, Musa MN, Senawi MY, Nasution H. Achieving a better energy-efficient automotive air-conditioning system: a review of potential technologies and strategies for vapor compression refrigeration cycle. Energy Efficiency. 2015;8(6):1201-29. doi:10.1007/s12053-015-9389-4.
  6. [6] Bi S-s, Shi L, Zhang L-l. Application of nanoparticles in domestic refrigerators. Applied Thermal Engineering. 2008;28(14-15):1834-43. doi:10.1016/j.applthermaleng.2007.11.018.
  7. [7] Xing M, Wang R, Yu J. Application of fullerene C60 nano-oil for performance enhancement of domestic refrigerator compressors. International Journal of Refrigeration. 2014;40:398-403. doi:10.1016/j.ijrefrig.2013.12.004.
  8. [8] Bi S, Guo K, Liu Z, Wu J. Performance of a domestic refrigerator using TiO2-R600a nano-refrigerant as working fluid. Energy Conversion and Management. 2011;52(1):733-7. doi:10.1016/j.enconman.2010.07.052.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Kasni Sumeru * This is me
0000-0003-3052-9610
Indonesia

Mohamad Firdaus Sukri This is me
0000-0002-0385-6897
Malaysia

Pratikto Pratikto This is me
0000-0003-4335-2324
Indonesia

Apip Badarudin This is me
0000-0001-6241-1532
Indonesia

Publication Date

April 1, 2020

Submission Date

April 23, 2019

Acceptance Date

August 27, 2019

Published in Issue

Year 2020 Volume: 6 Number: 3

APA
Sumeru, K., Sukri, M. F., Pratikto, P., & Badarudin, A. (2020). INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290. Journal of Thermal Engineering, 6(3), 297-312. https://doi.org/10.18186/thermal.711539
AMA
1.Sumeru K, Sukri MF, Pratikto P, Badarudin A. INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290. Journal of Thermal Engineering. 2020;6(3):297-312. doi:10.18186/thermal.711539
Chicago
Sumeru, Kasni, Mohamad Firdaus Sukri, Pratikto Pratikto, and Apip Badarudin. 2020. “INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290”. Journal of Thermal Engineering 6 (3): 297-312. https://doi.org/10.18186/thermal.711539.
EndNote
Sumeru K, Sukri MF, Pratikto P, Badarudin A (April 1, 2020) INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290. Journal of Thermal Engineering 6 3 297–312.
IEEE
[1]K. Sumeru, M. F. Sukri, P. Pratikto, and A. Badarudin, “INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290”, Journal of Thermal Engineering, vol. 6, no. 3, pp. 297–312, Apr. 2020, doi: 10.18186/thermal.711539.
ISNAD
Sumeru, Kasni - Sukri, Mohamad Firdaus - Pratikto, Pratikto - Badarudin, Apip. “INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290”. Journal of Thermal Engineering 6/3 (April 1, 2020): 297-312. https://doi.org/10.18186/thermal.711539.
JAMA
1.Sumeru K, Sukri MF, Pratikto P, Badarudin A. INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290. Journal of Thermal Engineering. 2020;6:297–312.
MLA
Sumeru, Kasni, et al. “INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290”. Journal of Thermal Engineering, vol. 6, no. 3, Apr. 2020, pp. 297-12, doi:10.18186/thermal.711539.
Vancouver
1.Kasni Sumeru, Mohamad Firdaus Sukri, Pratikto Pratikto, Apip Badarudin. INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290. Journal of Thermal Engineering. 2020 Apr. 1;6(3):297-312. doi:10.18186/thermal.711539

Cited By

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering