Abstract

Low temperature is the key to maintain the high quality for chilled food. The single jet air curtain is used for doorways opening insulation in the current circumstances is an idealization of the single jet air curtain used in the supermarket open refrigerated display cabinets. Open refrigerated display cabinets are going through some of the changes in their thermal behavior and of its overall performance due to variations in air conditions like air curtain temperature, velocity, height/width ratio, deflection module, specific cooling load, stability and thermal efficiency. A detailed experimental and comprehensive Artificial Neural Network Analysis of air conditions and energy transfer in an open refrigerated display cabinet is performed in this study. Numerical ANN predictions are 99.77% accurate and can be used to enable quick calculations and parametric analyses for the designing purposes of open refrigeration equipment that reduce the thermal infiltration of the Open Refrigerated Display Cabinet and increase the food safety.

Keywords

References

  1. [1] Akash MS. Artificial intelligence & neural networks. International Journal of Soft Computing and Artificial Intelligence. 2015; 3(2), 37-44.
  2. [2] ASHRAE Handbook: Refrigeration, American Society of Heating, Refrigerating and Air-Conditioning Engineers Incorporation. 2015.
  3. [3] Axell, M, Fahlén P. Design criteria for energy efficient vertical air curtains in display cabinets. Proceedings of 21st IIR International Congress of Refrigeration 2003; Washington DC, U.S.A.
  4. [4] Chen, YG., Yuan XL. Experimental study of the performance of single-band air curtains for multi-deck refrigerated display cabinet. Journal of Food Engineering 2005; 69(3), 261-267. doi:10.1016/j.jfoodeng.2004.08.016
  5. [5] Cortella, G, Manzan M, Comini G. CFD simulation of refrigerated display cabinets. International Journal of Refrigeration 2001; 24(3), 250-260. doi:10.1016/S0140-7007(00)00015-3.
  6. [6] Faramarzi, R. Efficient display case refrigeration, ASHRAE Journal 1999, 41(11).
  7. [7] Gaspar, PD, Gonçalves LCC, Pitarma RA. Experimental analysis of the thermal entrainment factor of air curtains in vertical open display cabinets for different ambient air conditions. Applied Thermal Engineering 2011; 31(5), 961–969. doi:10.1016/j.applthermaleng.2010.11.020.
  8. [8] Gray I, Luscombe P, McLean L, Sarathy CSP, Sheahen P, Srinivasan K. Improvement of air distribution in refrigerated vertical open front remote supermarket display cases. International Journal of Refrigeration 2008; 31(5), 902-910. doi:10.1016/j.ijrefrig.2007.09.005.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Note

Authors

Vipin Kumar Titariya * This is me
0000-0002-5573-0305
India

Alka Bani Agarwal This is me
India

Publication Date

April 1, 2020

Submission Date

July 3, 2018

Acceptance Date

October 22, 2018

Published in Issue

Year 2020 Volume: 6 Number: 3

APA
Titariya, V. K., & Agarwal, A. B. (2020). PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK. Journal of Thermal Engineering, 6(3), 359-368. https://doi.org/10.18186/thermal.712636
AMA
1.Titariya VK, Agarwal AB. PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK. Journal of Thermal Engineering. 2020;6(3):359-368. doi:10.18186/thermal.712636
Chicago
Titariya, Vipin Kumar, and Alka Bani Agarwal. 2020. “PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK”. Journal of Thermal Engineering 6 (3): 359-68. https://doi.org/10.18186/thermal.712636.
EndNote
Titariya VK, Agarwal AB (April 1, 2020) PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK. Journal of Thermal Engineering 6 3 359–368.
IEEE
[1]V. K. Titariya and A. B. Agarwal, “PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK”, Journal of Thermal Engineering, vol. 6, no. 3, pp. 359–368, Apr. 2020, doi: 10.18186/thermal.712636.
ISNAD
Titariya, Vipin Kumar - Agarwal, Alka Bani. “PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK”. Journal of Thermal Engineering 6/3 (April 1, 2020): 359-368. https://doi.org/10.18186/thermal.712636.
JAMA
1.Titariya VK, Agarwal AB. PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK. Journal of Thermal Engineering. 2020;6:359–368.
MLA
Titariya, Vipin Kumar, and Alka Bani Agarwal. “PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK”. Journal of Thermal Engineering, vol. 6, no. 3, Apr. 2020, pp. 359-68, doi:10.18186/thermal.712636.
Vancouver
1.Vipin Kumar Titariya, Alka Bani Agarwal. PERFORMANCE ANALYSIS OF THE SINGLE JET AIR CURTAIN FOR OPEN REFRIGERATED DISPLAY CABINET BY USING ARTIFICIAL NEURAL NETWORK. Journal of Thermal Engineering. 2020 Apr. 1;6(3):359-68. doi:10.18186/thermal.712636

Cited By

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering