Research Article

PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA

Volume: 7 Number: 1 January 1, 2021
  • Mokhtar Ghodbane *
  • Ahmed Kadhim Hussein
EN

PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA

Abstract

In order to understand the behavior and to determine the effective operational parameters of a solar-driven ejector air conditioning system at low or medium temperature, a dynamic model depends on the principles of conservation, the momentum mass and energy is developed. For this purpose, the thermodynamic characteristics of the liquid and vapor refrigerant were identified using the Engineering Equation Solver (EES) software. Linear Fresnel solar reflector has been used as a tool to convert solar energy into thermal energy. Water (R718) was used as a refrigerant. The operational conditions for the studied solar-driven ejector air conditioning system are as follows: evaporator temperature “Te =283.15 K”, condenser temperature “Tc =305.15 K”, and generator temperature “Tg = 373.15 K”. The performance of the ejector air conditioning system was compared as a function of the operating parameters of the subsystem. The average value of thermal efficiency of the Fresnel linear concentrator has reached 31.60 %, the drive ratio “ω” is 0.4934, the performance value of the ejector air conditioning subsystem “COPejc” is 60.664 % and the average value of the thermal performance of the machine “STR” has touched 19.17 %. The results obtained through this scientific subject are stimulating and encouraging, where this technique can be used for air conditioning in desert areas in southern Algeria, where fossil energy (petroleum, gas, etc.) is extracted and produced in various types.

Keywords

References

  1. [1] Kalogirou S A, Solar Energy Engineering : Processes and Systems. 1st ed. Academic Press; 2009.
  2. [2] Ghodbane M, Boumeddane B, Said N. A linear Fresnel reflector as a solar system for heating water: theoretical and experimental study. Case Studies in Thermal Engineering 2016; 8(C): 176-186. http://dx.doi.org/10.1016/j.csite.2016.06.006.
  3. [3] Ghodbane M, Boumeddane B, Moummi N, Largot S, Berkane H. Study and numerical simulation of solar system for air heating. Journal of Fundamental and Applied Sciences 2016; 8(1): 41- 60. http://dx.doi.org/10.4314/jfas.v8i1.3.
  4. [4] Rahman S, Issa S, Said Z, El Haj Assad M, Zadeh R, Barani Y. Performance enhancement of a solar powered air conditioning system using passive techniques and SWCNT /R-407c nano refrigerant. Case Studies in Thermal Engineering 2019; 16: 100565. https://doi.org/10.1016/j.csite.2019.100565.
  5. [5] Ghodbane M, Said Z, Hachicha AA, Boumeddane B. Performance assessment of linear Fresnel solar reflector using MWCNTs/DW nanofluids. Renewable Energy 2020; 151: 43-56. https://doi.org/10.1016/j.renene.2019.10.137.
  6. [6] Ghodbane M, Boumeddane B, Said N. Design and experimental study of a solar system for heating water utilizing a linear Fresnel reflector. Journal of Fundamental and Applied Sciences 2016; 8(3): 804-825. http://dx.doi.org/10.4314/jfas.v8i3.8.
  7. [7] Ghodbane M, Bellos E, Said Z, Boumeddane B, Hussein AK, Kolsi L. Evaluating energy efficiency and economic effect of heat transfer in copper tube for small solar linear Fresnel reflector. Journal of Thermal Analysis and Calorimetry 2020. https://doi.org/10.1007/s10973-020-09384-6.
  8. [8] Mosleh HJ, Hakkaki-Fard A, DaqiqShirazi M. A year-round dynamic simulation of a solar combined, ejector cooling, heating and power generation system. Applied Thermal Engineering 2019. https://doi.org/10.1016/j.applthermaleng.2019.02.114.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Mokhtar Ghodbane * This is me
0000-0003-1350-8631
Algeria

Ahmed Kadhim Hussein This is me
0000-0002-4360-0159
Iraq

Publication Date

January 1, 2021

Submission Date

December 26, 2018

Acceptance Date

April 1, 2019

Published in Issue

Year 2021 Volume: 7 Number: 1

APA
Ghodbane, M., & Hussein, A. K. (2021). PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA. Journal of Thermal Engineering, 7(1), 172-189. https://doi.org/10.18186/thermal.847334
AMA
1.Ghodbane M, Hussein AK. PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA. Journal of Thermal Engineering. 2021;7(1):172-189. doi:10.18186/thermal.847334
Chicago
Ghodbane, Mokhtar, and Ahmed Kadhim Hussein. 2021. “PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA”. Journal of Thermal Engineering 7 (1): 172-89. https://doi.org/10.18186/thermal.847334.
EndNote
Ghodbane M, Hussein AK (January 1, 2021) PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA. Journal of Thermal Engineering 7 1 172–189.
IEEE
[1]M. Ghodbane and A. K. Hussein, “PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA”, Journal of Thermal Engineering, vol. 7, no. 1, pp. 172–189, Jan. 2021, doi: 10.18186/thermal.847334.
ISNAD
Ghodbane, Mokhtar - Hussein, Ahmed Kadhim. “PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA”. Journal of Thermal Engineering 7/1 (January 1, 2021): 172-189. https://doi.org/10.18186/thermal.847334.
JAMA
1.Ghodbane M, Hussein AK. PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA. Journal of Thermal Engineering. 2021;7:172–189.
MLA
Ghodbane, Mokhtar, and Ahmed Kadhim Hussein. “PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA”. Journal of Thermal Engineering, vol. 7, no. 1, Jan. 2021, pp. 172-89, doi:10.18186/thermal.847334.
Vancouver
1.Mokhtar Ghodbane, Ahmed Kadhim Hussein. PERFORMANCE ANALYSIS OF A SOLAR-DRIVEN EJECTOR AIR CONDITIONING SYSTEM UNDER EL-OUED CLIMATIC CONDITIONS, ALGERIA. Journal of Thermal Engineering. 2021 Jan. 1;7(1):172-89. doi:10.18186/thermal.847334

Cited By

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering