Natural disaster occurred at Japan Fukushima Daiichi
NPP in March 2011 showed that combination of natural disasters with a long term
black out which is not accepted as a design basis accident till that day could
be how dangerous. In this study case, inventory calculation in the spent fuel
pool, transmission from inventory to source term and atmospheric dispersion
calculation of source term were investigated, in a case of long term black out
accident that can occur in the AES 2006 design VVER-1200 type of NPP planned to
be built in Turkey.
AES 2006 design VVER – 1200 long term blackout accident spent fuel pool Mersin Akkuyu NPP PCCOSYMA software
Mart 2011’de Japonya Fukushima Daiichi Nükleer Güç
Santralinde (NGS) gerçekleşen doğal felaket nükleer çevrelere o güne değin
tasarıma esas kaza olarak kabul edilmeyen uzun süreli santral kararmasının
doğal afetler ile birleşince ne denli tehlikeli olabileceğini gösterdi. Bu tez
çalışmasında Mersin, Akkuyu’da kurulması planlanan AES 2006 tasarımı bir
VVER–1200 tipi NGS’de gerçekleşebilecek uzun süreli santral kararması kazası
durumunda kullanılmış yakıt havuzundaki envanter hesabı, envanterden kaynak
teriminin hesabı, kaynak terimin atmosferik dağılım hesapları ve sonucunda NGS
sahası yakınlarında bulunan kişilerin alması muhtemel radyasyon dozları ve acil
durum müdahaleleri incelenmiştir.
AES 2006 tasarımı VVER – 1200 uzun sureli santral kararması kazası kullanılmış yakıt havuzu Mersin Akkuyu NGS PCCOSYMA ORIGEN-ARP.