POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD

Abstract

Nuclear resonance fluorescence (NRF) supplies good information to study nuclear structure of isotopes. The main perquisite for excitation to occur, the incoming photon must have energy equal to one of the excited states of absorbing nucleus. After absorption of the photon, nucleus will have a transition to the excited state pertaining to photon energy and then the excited nucleus will decay back to the ground state by emitting a gamma ray that has energy equal to that excited state. This process is called nuclear resonance fluorescence (NRF). In this study, we estimated the optimum detector position by considering maximum photondetector interaction and counted photon amount. It can be concluded that maximum photon fluence is recorded at the under of the NRF target

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Hüseyin Ozan Tekin This is me
Üsküdar University, Vocational School of Health Services, Riotherapy Department, İstanbul, Turkey

Iskender Akkurt This is me
Süleyman Demirel University, Faculty of Art and Science, Physics Department, Isparta, Turkey

Publication Date

July 23, 2016

Submission Date

July 23, 2016

Acceptance Date

-

Published in Issue

Year 2016 Volume: 6 Number: 2

APA
Tekin, H. O., & Akkurt, I. (2016). POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT, 6(2), 79-81. https://izlik.org/JA76DF65FK
AMA
1.Tekin HO, Akkurt I. POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT. 2016;6(2):79-81. https://izlik.org/JA76DF65FK
Chicago
Tekin, Hüseyin Ozan, and Iskender Akkurt. 2016. “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”. TOJSAT 6 (2): 79-81. https://izlik.org/JA76DF65FK.
EndNote
Tekin HO, Akkurt I (July 1, 2016) POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT 6 2 79–81.
IEEE
[1]H. O. Tekin and I. Akkurt, “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”, TOJSAT, vol. 6, no. 2, pp. 79–81, July 2016, [Online]. Available: https://izlik.org/JA76DF65FK
ISNAD
Tekin, Hüseyin Ozan - Akkurt, Iskender. “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”. TOJSAT 6/2 (July 1, 2016): 79-81. https://izlik.org/JA76DF65FK.
JAMA
1.Tekin HO, Akkurt I. POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT. 2016;6:79–81.
MLA
Tekin, Hüseyin Ozan, and Iskender Akkurt. “POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD”. TOJSAT, vol. 6, no. 2, July 2016, pp. 79-81, https://izlik.org/JA76DF65FK.
Vancouver
1.Hüseyin Ozan Tekin, Iskender Akkurt. POSITION OPTIMISATION OF GE DETECTORS IN NUCLEAR RESONANCE FLUORESCENCE (NRF) EXPERIMENT BY USING MONTE CARLO METHOD. TOJSAT [Internet]. 2016 Jul. 1;6(2):79-81. Available from: https://izlik.org/JA76DF65FK