EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD

Volume: Volume 2 Number: İssue 1 (1) February 16, 2017
  • Ali Asci
  • Sera Simsek Derelioglu
  • Bilal Yilmaz
  • Taskin Gurbuz
  • Fatma Songur
EN

EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD

Abstract

Bisphenol A (BPA) is a chemical produced in large quantities for use primarily in the production of polycarbonate plastics and epoxy resins. BPA is also present in dental materials used to treat and prevent caries. There have been concerns raised regarding the safety of bisphenol A in dental sealants and composites. The aim of the study is to measure BPA levels which were released from composite resins after curing with different polymerization conditions. Four composite resins which are commonly used in dental clinics were used in the study. The resins were placed into a silicon mold (diameter: 5 mm; thickness: 2 mm) on a teflon plate and photopolymerized by LED light source using two different modes [Full-Mod (Mod-1) and Ramping Mod (Mod-2)]. After polymerization, cured composite resin specimens were soaked in 3 ml artificial saliva and stored at 37 C for 16 days. After 2 h, 24 h, 3 d, 7 d and 15 d, 250 µl specimens were taken in order to detect BPA release from dental resins by HPLC-UV detection. The linear ranges were found to be 5-2000 ppb. The regression equation was y=2.6726x-4.6396 (r =0.9993). Maximum and minimum BPA release from dental composites detected in Mod 1 were 174.04±9.7 and 9.30±0.16 while 10.15±0.3 and 218.0±9.5 in Mod 2, respectively. Release of BPA from dental restorative materials was ended after 15 days. In conclusion the absence of a continuous release of BPA from the dental materials is important in the clinical sense.  

Keywords

References

  1. Ali ASCİ, Sera Simsek DERELİOGLU, Bilal YİLMAZ, Taskin GURBUZ, Fatma SONGUR.
  2. Atatürk University, Faculty of Pharmacy, Department of Toxicology, Erzurum, Turkey Atatürk University, Faculty of Dentistry, Department of Pedodontics, Erzurum, Turkey Atatürk University, Faculty of Pharmacy, Department of Analytical Chemistry, Erzurum, Turkey

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Ali Asci This is me

Sera Simsek Derelioglu This is me

Bilal Yilmaz This is me

Taskin Gurbuz This is me

Fatma Songur This is me

Publication Date

February 16, 2017

Submission Date

May 22, 2017

Acceptance Date

-

Published in Issue

Year 2017 Volume: Volume 2 Number: İssue 1 (1)

APA
Asci, A., Derelioglu, S. S., Yilmaz, B., Gurbuz, T., & Songur, F. (2017). EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD. The Turkish Journal Of Occupational Environmental Medicine and Safety, Volume 2(İssue 1 (1), 276-276. https://izlik.org/JA92FP92KU
AMA
1.Asci A, Derelioglu SS, Yilmaz B, Gurbuz T, Songur F. EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD. turjoem. 2017;Volume 2(İssue 1 (1):276-276. https://izlik.org/JA92FP92KU
Chicago
Asci, Ali, Sera Simsek Derelioglu, Bilal Yilmaz, Taskin Gurbuz, and Fatma Songur. 2017. “EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD”. The Turkish Journal Of Occupational Environmental Medicine and Safety Volume 2 (İssue 1 (1): 276-76. https://izlik.org/JA92FP92KU.
EndNote
Asci A, Derelioglu SS, Yilmaz B, Gurbuz T, Songur F (February 1, 2017) EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD. The Turkish Journal Of Occupational / Environmental Medicine and Safety Volume 2 İssue 1 (1) 276–276.
IEEE
[1]A. Asci, S. S. Derelioglu, B. Yilmaz, T. Gurbuz, and F. Songur, “EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD”, turjoem, vol. Volume 2, no. İssue 1 (1), pp. 276–276, Feb. 2017, [Online]. Available: https://izlik.org/JA92FP92KU
ISNAD
Asci, Ali - Derelioglu, Sera Simsek - Yilmaz, Bilal - Gurbuz, Taskin - Songur, Fatma. “EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD”. The Turkish Journal Of Occupational / Environmental Medicine and Safety VOLUME 2/İssue 1 (1) (February 1, 2017): 276-276. https://izlik.org/JA92FP92KU.
JAMA
1.Asci A, Derelioglu SS, Yilmaz B, Gurbuz T, Songur F. EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD. turjoem. 2017;Volume 2:276–276.
MLA
Asci, Ali, et al. “EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD”. The Turkish Journal Of Occupational Environmental Medicine and Safety, vol. Volume 2, no. İssue 1 (1), Feb. 2017, pp. 276-, https://izlik.org/JA92FP92KU.
Vancouver
1.Ali Asci, Sera Simsek Derelioglu, Bilal Yilmaz, Taskin Gurbuz, Fatma Songur. EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD. turjoem [Internet]. 2017 Feb. 1;Volume 2(İssue 1 (1):276-. Available from: https://izlik.org/JA92FP92KU