BibTex RIS Cite

SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE

Year 2017, Volume: Volume 2 Issue: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 117 - 117, 16.02.2017

Abstract

In this study
the selective determination of tannic acid (TA) was performed using a glassy
carbon (GC) electrode modified with 1-Benzoyl-3-(pyrrolidine) thiourea (PrTu).
PrTuwas deposited on the GC electrode in nonaqueous media by cyclic
voltammetry. PrTu-GC electrode demonstrated an electrocatalytical effect on the
oxidation of TA using differential pulse voltammetry (DPV) method in 0.1 M
Britton Robinson (BR) buffer solution of pH 2. Under optimum conditions linear
calibration graphs were obtained over the TA concentration range 2.0×10−6 to
4.2×10−5 M. The detection of limit (LOD) was found as 0.6 µM. The proposed
electrode was applied to the determination of TA in tea sample with
satisfactory results.

References

  • Elif ÇALIK, Demet UZUN, Ümmihan Taşkoparan YILMAZ
  • Gazi University, Polatlı Science and Art Faculty, Department of Chemistry, 06900 Polatlı, Ankara/Turkey Gazi University, Science Faculty, Department of Chemistry, 06500, Ankara/Turkey
Year 2017, Volume: Volume 2 Issue: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 117 - 117, 16.02.2017

Abstract

References

  • Elif ÇALIK, Demet UZUN, Ümmihan Taşkoparan YILMAZ
  • Gazi University, Polatlı Science and Art Faculty, Department of Chemistry, 06900 Polatlı, Ankara/Turkey Gazi University, Science Faculty, Department of Chemistry, 06500, Ankara/Turkey
There are 2 citations in total.

Details

Journal Section Articles
Authors

Elif Çalık This is me

Demet Uzun This is me

Ümmihan Taşkoparan Yılmaz This is me

Publication Date February 16, 2017
Published in Issue Year 2017 Volume: Volume 2 Issue: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology

Cite

APA Çalık, E., Uzun, D., & Yılmaz, Ü. T. (2017). SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. The Turkish Journal Of Occupational / Environmental Medicine and Safety, Volume 2(İssue 1 (1), 117-117.
AMA Çalık E, Uzun D, Yılmaz ÜT. SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. turjoem. February 2017;Volume 2(İssue 1 (1):117-117.
Chicago Çalık, Elif, Demet Uzun, and Ümmihan Taşkoparan Yılmaz. “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”. The Turkish Journal Of Occupational / Environmental Medicine and Safety Volume 2, no. İssue 1 (1) (February 2017): 117-17.
EndNote Çalık E, Uzun D, Yılmaz ÜT (February 1, 2017) SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. The Turkish Journal Of Occupational / Environmental Medicine and Safety Volume 2 İssue 1 (1) 117–117.
IEEE E. Çalık, D. Uzun, and Ü. T. Yılmaz, “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”, turjoem, vol. Volume 2, no. İssue 1 (1), pp. 117–117, 2017.
ISNAD Çalık, Elif et al. “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”. The Turkish Journal Of Occupational / Environmental Medicine and Safety VOLUME 2/İssue 1 (1) (February 2017), 117-117.
JAMA Çalık E, Uzun D, Yılmaz ÜT. SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. turjoem. 2017;Volume 2:117–117.
MLA Çalık, Elif et al. “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”. The Turkish Journal Of Occupational / Environmental Medicine and Safety, vol. Volume 2, no. İssue 1 (1), 2017, pp. 117-.
Vancouver Çalık E, Uzun D, Yılmaz ÜT. SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. turjoem. 2017;Volume 2(İssue 1 (1):117-.