Abstract

The use of state-of-the-art technical textiles instead of lead aprons is of great importance due to their lightweight, flexible, non-toxic and comfortable composition. In this study, we aimed to determine the disadvantages experienced by healthcare workers due to lead aprons and their opinions about innovative protective clothing. The survey, comprising seventeen questions, aimed to gather demographic information, design and physical properties of respondents' lead aprons, functionality, comfort, and performance of current protective clothing, and determine future design requirements. Within the scope of the research, a survey was administered to 52 radiation workers, and the results were analyzed statistically. Radiology technicians comprised nearly half of the respondents (34%), followed by physicians (25.5%) and nurses (19.1%). The most important problems encountered by the respondents during the use of lead aprons were defined as being heavy, restricting movement, and not fitting the body properly. Among the comfort descriptors, inability to move comfortably, weight and air permeability were considered "completely important" by the respondents, respectively. The study showed that 26.92% of the participants experienced complications with their lumbar spine, while 23.08% reported concerns with their cervical spine. Survey participants noted low air permeability and thermal comfort in lead aprons, making them unsuitable for various anatomical structures. To overcome these issues, technical textiles with easier shapeability and improved performance, such as mechanical properties and insulation, could be used instead.In order to overcome these disadvantages, producing and using technical textiles instead of lead aprons will provide a significant advantage.

Keywords

Supporting Institution

This research was funded by the Scientific and Technological Research Council of Türkiye (Grant No. 123F192).

Project Number

Grant No. 123F192

Ethical Statement

Ethical approval of this study was obtained from the institutional ethics committee of the Usak University Science and Engineering Scientific Research and Publication Ethics Board (12.12.2023 / 2023-34).

References

  1. Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JA, et al. Strategies for CT radiation dose optimization, Radiology, 2004;230(3):619–28.
  2. Morishima Y, Chida K, Katahira Y. The effectiveness of additional lead-shielding drape and low pulse rate fluoroscopy in protecting staff from scatter radiation during cardiac resynchronization therapy (CRT), Jpn J Radiol, 2019;37(2):95–101.
  3. Jiang X, Zhu X, Chang C, Liu S, Luo X. X-ray shielding structural and properties design for the porous transparent BaSO4/cellulose nanocomposite membranes, Int J Biol Macromol, 2019;139:793–800.
  4. Chung DDL, Eddib AA. Effect of fiber lay-up configuration on the electromagnetic interference shielding effectiveness of continuous carbon fiber polymer-matrix composite, Carbon, 2019;141:685–91.
  5. Şahin MC, Manisa K. Evaluation of X-ray shielding ability of tungsten rubber: A GAMOS Monte Carlo study, Süleyman Demirel University Faculty of Arts and Science Journal of Science, 2023;18(1):1–9.
  6. AbuAlRoos NJ, Baharul Amin NA, Zainon R. Conventional and new lead-free radiation shielding materials for radiation protection in nuclear medicine: A review, Radiat Phys Chem, 2019;165:108439.
  7. Moore B, vanSonnenberg E, Casola G, Novelline RA. The relationship between back pain and lead apron use in radiologists, Am J Roentgenol, 1992;158(1):191–3.
  8. Andrew S, Abdelmonem MR, Kohli S, Dabke H. Evaluation of back pain and lead apron use among staff at a district general hospital, Cureus, 2021.

Details

Primary Language

English

Subjects

Medical Devices, Textile Technology

Journal Section

Research Article

Publication Date

December 30, 2024

Submission Date

June 15, 2024

Acceptance Date

December 3, 2024

Published in Issue

Year 2024 Volume: 7 Number: 2

APA
Şahin, M. C., Ünay Çubukçu, N., & Oner, E. (2024). The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences. Usak University Journal of Engineering Sciences, 7(2), 106-116. https://doi.org/10.47137/uujes.1501906
AMA
1.Şahin MC, Ünay Çubukçu N, Oner E. The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences. UUJES. 2024;7(2):106-116. doi:10.47137/uujes.1501906
Chicago
Şahin, Meryem Cansu, Nilüfer Ünay Çubukçu, and Eren Oner. 2024. “The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences”. Usak University Journal of Engineering Sciences 7 (2): 106-16. https://doi.org/10.47137/uujes.1501906.
EndNote
Şahin MC, Ünay Çubukçu N, Oner E (December 1, 2024) The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences. Usak University Journal of Engineering Sciences 7 2 106–116.
IEEE
[1]M. C. Şahin, N. Ünay Çubukçu, and E. Oner, “The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences”, UUJES, vol. 7, no. 2, pp. 106–116, Dec. 2024, doi: 10.47137/uujes.1501906.
ISNAD
Şahin, Meryem Cansu - Ünay Çubukçu, Nilüfer - Oner, Eren. “The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences”. Usak University Journal of Engineering Sciences 7/2 (December 1, 2024): 106-116. https://doi.org/10.47137/uujes.1501906.
JAMA
1.Şahin MC, Ünay Çubukçu N, Oner E. The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences. UUJES. 2024;7:106–116.
MLA
Şahin, Meryem Cansu, et al. “The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences”. Usak University Journal of Engineering Sciences, vol. 7, no. 2, Dec. 2024, pp. 106-1, doi:10.47137/uujes.1501906.
Vancouver
1.Meryem Cansu Şahin, Nilüfer Ünay Çubukçu, Eren Oner. The Disadvantages of Lead Aprons and the Need for Innovative Protective Clothing: A Survey Study on Healthcare Workers’ Opinions and Experiences. UUJES. 2024 Dec. 1;7(2):106-1. doi:10.47137/uujes.1501906

Cited By

An international scientific e-journal published by the University of Usak