Analysis of Failure of an Uninterruptible Power Supply of Office Building as an Instructional Case Study

Abstract

In the engineering education, along with the instructions via theoretical basis and laboratory and workshop studies, the students should meet with the real life problems in their education period. This provides the problem solving ability to the students in their professional life. The department of electrical education has a course on the determination and elimination of failures in an existing electrical system. The subject is designed as a student centered education in which the student must investigate the possible reason and solution of the problem and report it accordingly. Recently a case of failure of an uninterruptible power supply (UPS) system is reported. The use of UPS is widespread especially for sensitive equipments to the variation of current voltage. This equipments is used for both as an energy source for the cut offs and as a regulator for the discrepancy. The failure in the system caused a fatal defect to the Isolation Gate Bipolar Transistors (IGBT) on the UPS system. In the present study, the case of failure for the UPS system used in a three storey office building is analyzed as an instructional case study. Anahtar Kelimeler: Failure analysis, Uninterruptible power supply, Power quality, Wiring

Keywords

Details

Primary Language

Turkish

Subjects

-

Journal Section

-

Authors

Hasan Cımen This is me
Kocatepe University, Technical Education Faculty, ANS Campus, Afyonkarahisar, TURKEY

Suleyman Tasgetıren This is me
Kocatepe University, Technical Education Faculty, ANS Campus, Afyonkarahisar, TURKEY

Publication Date

June 22, 2016

Submission Date

June 22, 2016

Acceptance Date

-

Published in Issue

Year 2008 Volume: 4 Number: 1

APA
Cımen, H., & Tasgetıren, S. (2016). Analysis of Failure of an Uninterruptible Power Supply of Office Building as an Instructional Case Study. Yapı Teknolojileri Elektronik Dergisi, 4(1), 59-66. https://izlik.org/JA25ET85BE
AMA
1.Cımen H, Tasgetıren S. Analysis of Failure of an Uninterruptible Power Supply of Office Building as an Instructional Case Study. yted. 2016;4(1):59-66. https://izlik.org/JA25ET85BE
Chicago
Cımen, Hasan, and Suleyman Tasgetıren. 2016. “Analysis of Failure of an Uninterruptible Power Supply of Office Building As an Instructional Case Study”. Yapı Teknolojileri Elektronik Dergisi 4 (1): 59-66. https://izlik.org/JA25ET85BE.
EndNote
Cımen H, Tasgetıren S (June 1, 2016) Analysis of Failure of an Uninterruptible Power Supply of Office Building as an Instructional Case Study. Yapı Teknolojileri Elektronik Dergisi 4 1 59–66.
IEEE
[1]H. Cımen and S. Tasgetıren, “Analysis of Failure of an Uninterruptible Power Supply of Office Building as an Instructional Case Study”, yted, vol. 4, no. 1, pp. 59–66, June 2016, [Online]. Available: https://izlik.org/JA25ET85BE
ISNAD
Cımen, Hasan - Tasgetıren, Suleyman. “Analysis of Failure of an Uninterruptible Power Supply of Office Building As an Instructional Case Study”. Yapı Teknolojileri Elektronik Dergisi 4/1 (June 1, 2016): 59-66. https://izlik.org/JA25ET85BE.
JAMA
1.Cımen H, Tasgetıren S. Analysis of Failure of an Uninterruptible Power Supply of Office Building as an Instructional Case Study. yted. 2016;4:59–66.
MLA
Cımen, Hasan, and Suleyman Tasgetıren. “Analysis of Failure of an Uninterruptible Power Supply of Office Building As an Instructional Case Study”. Yapı Teknolojileri Elektronik Dergisi, vol. 4, no. 1, June 2016, pp. 59-66, https://izlik.org/JA25ET85BE.
Vancouver
1.Hasan Cımen, Suleyman Tasgetıren. Analysis of Failure of an Uninterruptible Power Supply of Office Building as an Instructional Case Study. yted [Internet]. 2016 Jun. 1;4(1):59-66. Available from: https://izlik.org/JA25ET85BE