The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty

Yıl 2011, Cilt: 45 Sayı: 3, 190 - 194, 15.07.2011

Öz

Objective: We aimed to determine and compare the effects of intraoperative bleeding control and two hours postoperative drain clamping method on postoperative wound drainage and the need for donor blood transfusion following total knee arthroplasty (TKA).
Methods: Seventy-one patients who underwent TKA were randomly assigned into two groups. Fourty-four knees of 32 patients comprised Group A and 51 knees of 39 patients comprised Group B. In Group A, no bleeding control was done and postoperatively, the drain was clamped for 2 hours. Then it was unclamped to begin aspiration after the 2nd hour. In Group B, the bleeding was controlled intraoperatively, and the drain was not clamped after the surgery. Drains were removed 48 hours after the surgery in both groups. Bilateral and unilateral arthroplasty patients were evaluated separately. The groups were compared for their preoperative and postoperative 3-day haemoglobin (Hb) levels, total drainage amount and total number of blood transfusions.
Results: The haemoglobin levels were similar in both groups preoperatively and at the 1st, 2nd and 3rd postoperative days. In Group A, the wound drainage was 696.1±235.4 ml in unilateral TKA patients and was 1010.8±535.5 ml in bilateral arthroplasty patients. In Group B, the wound drainage was 710.1±380.1 ml in unilateral TKA patients and was 878.3±489.6 ml in bilateral arthroplasty patients. The mean number of transfusions was 1.41 units with no significant differences between the groups.
Conclusion: The two hour drain clamping method without intraoperative bleeding control does not seem to affect the amount of blood loss and the need for transfusion when compared to intraoperative bleeding control in total knee arthroplasty patients. Hovewer, it is a simple and feasible method and can be used to decrease the operation time. 

Yıl 2011, Cilt: 45 Sayı: 3, 190 - 194, 15.07.2011

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Sağlık Kurumları Yönetimi
Bölüm Orijinal Makale
Yazarlar

Yusuf Aksoy Bu kişi benim

Levent Altinel Bu kişi benim

Kamil Kose Bu kişi benim

Yayımlanma Tarihi 15 Temmuz 2011
Yayımlandığı Sayı Yıl 2011 Cilt: 45 Sayı: 3

Kaynak Göster

APA Aksoy, Y., Altinel, L., & Kose, K. (2011). The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty. Acta Orthopaedica Et Traumatologica Turcica, 45(3), 190-194.
AMA Aksoy Y, Altinel L, Kose K. The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty. Acta Orthopaedica et Traumatologica Turcica. Temmuz 2011;45(3):190-194.
Chicago Aksoy, Yusuf, Levent Altinel, ve Kamil Kose. “The Comparison of the Effects of Intraoperative Bleeding Control and Postoperative Drain Clamping Methods on the Postoperative Blood Loss and the Need for Transfusion Following Total Knee Arthroplasty”. Acta Orthopaedica Et Traumatologica Turcica 45, sy. 3 (Temmuz 2011): 190-94.
EndNote Aksoy Y, Altinel L, Kose K (01 Temmuz 2011) The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty. Acta Orthopaedica et Traumatologica Turcica 45 3 190–194.
IEEE Y. Aksoy, L. Altinel, ve K. Kose, “The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty”, Acta Orthopaedica et Traumatologica Turcica, c. 45, sy. 3, ss. 190–194, 2011.
ISNAD Aksoy, Yusuf vd. “The Comparison of the Effects of Intraoperative Bleeding Control and Postoperative Drain Clamping Methods on the Postoperative Blood Loss and the Need for Transfusion Following Total Knee Arthroplasty”. Acta Orthopaedica et Traumatologica Turcica 45/3 (Temmuz 2011), 190-194.
JAMA Aksoy Y, Altinel L, Kose K. The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty. Acta Orthopaedica et Traumatologica Turcica. 2011;45:190–194.
MLA Aksoy, Yusuf vd. “The Comparison of the Effects of Intraoperative Bleeding Control and Postoperative Drain Clamping Methods on the Postoperative Blood Loss and the Need for Transfusion Following Total Knee Arthroplasty”. Acta Orthopaedica Et Traumatologica Turcica, c. 45, sy. 3, 2011, ss. 190-4.
Vancouver Aksoy Y, Altinel L, Kose K. The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty. Acta Orthopaedica et Traumatologica Turcica. 2011;45(3):190-4.