Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study

Abstract

Objective: The purpose of this study was to biomechanically compare cable, trochanteric grip plate, and locking plate techniques in Vancouver type AG fracture model in an in vitro test environment.
Methods: Fifteen pieces of fourth-generation synthetic femora were separated into 3 groups of 5 models each. A greater trochanteric fracture model was created after femoral stem implantation. Group 1 was fixated with only cable, Group 2 with trochanteric grip plate, and Group 3 with locking plate. Horizontal stiffness, axial stiffness, and failure loads were compared between the groups.
Results: In horizontal compression tests, Group 3 had the highest values, but the only statistically significant difference was between the locking plate group and cable group. Axial distraction test results showed that mean stiffness of Group 1 was 94.6±9.44 N/mm, that of Group 2 was 174.8±28.64 N/mm, and that of Group 3 was 185.6±71.64 N/mm. While locking plate versus cable fixation and grip plate fixation versus cable fixation showed statistically significant differences (p<0.05), comparison of locking plate versus grip plate fixation showed no statistically significant difference (p>0.05). In axial failure load test, Group 3 had the highest results. The only significant difference was between the locking plate and cable groups (p<0.05).
Conclusion: In Vancouver type AG fractures stable fixation may be achieved with grip plate fixation and locking plates, with the former ensuring more stable osteosynthesis.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yayımlanma Tarihi

26 Nisan 2016

Gönderilme Tarihi

18 Kasım 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1970 Cilt: 50 Sayı: 3

Kaynak Göster

APA
Sarıyılmaz, K., Korkmaz, M., Özkunt, O., Gemalmaz, H. C., Sungur, M., & Baydoğan, M. (2016). Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica, 50(3), 373. https://izlik.org/JA97AH45RE
AMA
1.Sarıyılmaz K, Korkmaz M, Özkunt O, Gemalmaz HC, Sungur M, Baydoğan M. Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica. 2016;50(3):373. https://izlik.org/JA97AH45RE
Chicago
Sarıyılmaz, Kerim, Murat Korkmaz, Okan Özkunt, Halil Can Gemalmaz, Mustafa Sungur, ve Murat Baydoğan. 2016. “Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study”. Acta Orthopaedica et Traumatologica Turcica 50 (3): 373. https://izlik.org/JA97AH45RE.
EndNote
Sarıyılmaz K, Korkmaz M, Özkunt O, Gemalmaz HC, Sungur M, Baydoğan M (01 Nisan 2016) Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica 50 3 373.
IEEE
[1]K. Sarıyılmaz, M. Korkmaz, O. Özkunt, H. C. Gemalmaz, M. Sungur, ve M. Baydoğan, “Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study”, Acta Orthopaedica et Traumatologica Turcica, c. 50, sy 3, s. 373, Nis. 2016, [çevrimiçi]. Erişim adresi: https://izlik.org/JA97AH45RE
ISNAD
Sarıyılmaz, Kerim - Korkmaz, Murat - Özkunt, Okan - Gemalmaz, Halil Can - Sungur, Mustafa - Baydoğan, Murat. “Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study”. Acta Orthopaedica et Traumatologica Turcica 50/3 (01 Nisan 2016): 373. https://izlik.org/JA97AH45RE.
JAMA
1.Sarıyılmaz K, Korkmaz M, Özkunt O, Gemalmaz HC, Sungur M, Baydoğan M. Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica. 2016;50:373.
MLA
Sarıyılmaz, Kerim, vd. “Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study”. Acta Orthopaedica et Traumatologica Turcica, c. 50, sy 3, Nisan 2016, s. 373, https://izlik.org/JA97AH45RE.
Vancouver
1.Kerim Sarıyılmaz, Murat Korkmaz, Okan Özkunt, Halil Can Gemalmaz, Mustafa Sungur, Murat Baydoğan. Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Nisan 2016;50(3):373. Erişim adresi: https://izlik.org/JA97AH45RE