Research Article

ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER

Volume: 61 Number: 2 December 1, 2019
EN

ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER

Abstract

In this study, a novel tapered optical fiber sensor based on a Mach–Zehnder interferometer (MZI) for refractive index measurement is proposed. Our sensor is constructed with two up-tapers symmetrically placed in a down-taper single mode fiber. Although its waist diameter is as thick as 55 μm, the sensor can measure the refractive index. Simulation results demonstrate RI sensitivities of -94 nm/RIU and -125 nm/RIU at the lower and higher wavelength of the spectrum. The sensor is extremely robust, it can be easily manufactured and it can be used not only for RI but also for simultaneous strain and temperature measurements.

Keywords

References

  1. Ji, W. B., Liu, H. H., Tjin, S. C., Chow, K. K. and Lim, A., Ultrahigh sensitivity refractive index sensor based on optical microfiber, IEEE Phot. Tech. Lett., 24 (2012) 1872-1874.
  2. Lacroix, S., Gonthier, F., Black R. J., and Bures, J., Tapered-fiber interferometric wavelength response: the achromatic fringe, Opt. Lett., 13 (1988) 395-397.
  3. Bariáin, C., Matías, I.R., Arregui, F. J. and López-Amo, M., Tapered optical-fiber-based pressure sensor, Opt. Eng., 39 (2000) 2241-2247.
  4. Massaro, A., Spano, F., Missori, M., Malvindi, M. A., Cazzato, P., Cingolani, R. and Athanassiou, A., Flexible nanocomposites with all-optical tactile sensing capability, RSC Adv., 4, (2014) 2820-2825.
  5. Lu, P., Men, L., Sooley, K. and Chen, Q., Tapered fiber Mach–Zehnder interferometer for simultaneous measurement of refractive index and temperature, Appl. Phys. Lett., 94, (2009) 131110-131110-(3).
  6. Shao, L-Y., Zhao, J., Dong, X., Tam, H. Y., Lu, C. and He, S., Long-period grating fabricated by periodically tapering standard single-mode fiber, App. Optics, 47 (2007) 1549-1552.
  7. Bariáin, C., Matías, I. R., Fernández-Valdivielso, C., Arregui, F. J., Rodríguez-Méndez, M. L. and Saja, J. A., Optical fiber sensor based on lutetium bisphthalocyanine for the detection of gases using standard telecommunication wavelengths, Sens. Act. B Chem., 93 (2003) 153-158.
  8. Corres, J. M., Matías, I. R., Bravo, J. and Arregui, F. J., Tapered optical fiber biosensor for the detection of anti-gliadin antibodies, Sens. Act. B, Chem., 135 (2008) 166-171.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

December 1, 2019

Submission Date

July 18, 2019

Acceptance Date

October 11, 2019

Published in Issue

Year 1970 Volume: 61 Number: 2

APA
Navruz, İ., & Bilsel, M. (2019). ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering, 61(2), 172-180. https://doi.org/10.33769/aupse.593754
AMA
1.Navruz İ, Bilsel M. ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER. Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng. 2019;61(2):172-180. doi:10.33769/aupse.593754
Chicago
Navruz, İsa, and Mustafa Bilsel. 2019. “ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER”. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering 61 (2): 172-80. https://doi.org/10.33769/aupse.593754.
EndNote
Navruz İ, Bilsel M (December 1, 2019) ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering 61 2 172–180.
IEEE
[1]İ. Navruz and M. Bilsel, “ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER”, Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng., vol. 61, no. 2, pp. 172–180, Dec. 2019, doi: 10.33769/aupse.593754.
ISNAD
Navruz, İsa - Bilsel, Mustafa. “ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER”. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering 61/2 (December 1, 2019): 172-180. https://doi.org/10.33769/aupse.593754.
JAMA
1.Navruz İ, Bilsel M. ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER. Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng. 2019;61:172–180.
MLA
Navruz, İsa, and Mustafa Bilsel. “ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER”. Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering, vol. 61, no. 2, Dec. 2019, pp. 172-80, doi:10.33769/aupse.593754.
Vancouver
1.İsa Navruz, Mustafa Bilsel. ROBUST REFRACTIVE INDEX FIBER SENSOR BASED ON TWO UP-TAPERS PLACED IN DOWN-TAPER. Commun.Fac.Sci.Univ.Ank.Series A2-A3: Phys.Sci. and Eng. 2019 Dec. 1;61(2):172-80. doi:10.33769/aupse.593754

Communications Faculty of Sciences University of Ankara Series A2-A3 Physical Sciences and Engineering licensed under a Creative Commons Attribution 4.0 International License.

Creative Commons License