Research Article

Evaluation of distal femur fractures in cats by hybrid external fixator

Volume: 71 Number: 1 January 2, 2024
EN

Evaluation of distal femur fractures in cats by hybrid external fixator

Abstract

In this study, clinical and radiological findings obtained from the treatment of distal femur fractures in cats with hybrid external fixator were evaluated. A total of 10 cats of different ages, breeds and genders with clinically diagnosed femur fractures were used as research material. In the study, hybrid external fixators consisting of circular and linear fixators were used as osteosynthesis material. Closed reduction and external fixation methods were used in 2 cases diagnosed with closed fractures, while limited open reduction and external fixation methods were used in 8 cases diagnosed with open fractures or excessive dislocations. In the radiological examination findings, it was determined that fracture consolidation started on the post-operative 7th day in 9 cases and on the 10th day in 1 case, respectively. Fracture healing was completed in 4 weeks in 2 cases, in 5 weeks in 2 cases, and in 6 weeks in 6 cases (osseous callus was detected). Fixators were removed one week after healing was completed in all patients. In the study, soft tissue complications such as edema in the extremities in 3 cases, mild pin infection in 3 cases and open wounds in 4 cases were determined. However, it was observed that these complications did not adversely affect the recovery time. As a result, with the data obtained from the study, it was concluded that the distal femur fractures in cats of the age and weight scales examined in the study can be successfully treated with the hybrid external fixator system.

Keywords

Supporting Institution

This research has been supported within the content of the project no TDK-2018-7750 by research fund of Van Yüzüncü Yıl University.

Project Number

TDK-2018-7750

Ethical Statement

This study was carried out after the animal experiment was approved by Siirt University Local Ethics Committee (Decision number: 2018/16).

Thanks

This study was derived from the PhD thesis of the first author. We would like to thank the Tasarım Med Firm for their support.

References

  1. Altunatmaz K, Karabağlı M, Aydın Kaya D, et al (2017): The treatment of supracondylar and diaphyseal femoral fractures in cats using intramedullary two-way stacked Kirschner wire application. Turk J Vet Anim Sci, 41, 282-287.
  2. Anderson DA, St Jean G (1996): External skeletal fixation in ruminants. Adv Rum Orthop, 12, 117-152.
  3. Aslanbey D (2002): Veteriner Ortopedi ve Travmatoloji. Özkan Matbaacılık, Ankara.
  4. Beale B (2004): Orthopedic clinical techniques femur fracture repair. ClinTech Small Anim Pract, 19, 134-150.
  5. Bilgili H (2004): Circular external fixation system of Ilizarov: part V. Fracture treatment by the Ilizarov technique. Vet Cer Derg, 10, 75-89.
  6. Bilgili H, Aslanbey D (2000): Uzun kemiklerin epifizer bölge kırıkları: Bölüm IV. kedi ve köpeklerde distal epifizer bölge kırıklarında sağaltım metodlarının karşılaştırmalı olarak araştırılması. Vet Cer Derg, 6, 12-21.
  7. Bilgili H, Yıldırım M, Olcay B (1999): The complication of pin track infection causedy using Ilizarov’s circular external fixator on tibia of dogs. Turk J Vet Surg, 5, 41-44.
  8. Ferretti A (1991): The Application of the Ilizarov technique to veterinary medicine. 551–570. In: Maiocchi AB, Aronson J (Ed), Operative principles of Ilizarov appendix. ASAMI Group, İtaly.

Details

Primary Language

English

Subjects

Veterinary Surgery

Journal Section

Research Article

Publication Date

January 2, 2024

Submission Date

January 27, 2022

Acceptance Date

November 15, 2022

Published in Issue

Year 2024 Volume: 71 Number: 1

APA
Gülaydın, A., & Alkan, İ. (2024). Evaluation of distal femur fractures in cats by hybrid external fixator. Ankara Üniversitesi Veteriner Fakültesi Dergisi, 71(1), 89-100. https://doi.org/10.33988/auvfd.1063887
AMA
1.Gülaydın A, Alkan İ. Evaluation of distal femur fractures in cats by hybrid external fixator. Ankara Univ Vet Fak Derg. 2024;71(1):89-100. doi:10.33988/auvfd.1063887
Chicago
Gülaydın, Ali, and İsmail Alkan. 2024. “Evaluation of Distal Femur Fractures in Cats by Hybrid External Fixator”. Ankara Üniversitesi Veteriner Fakültesi Dergisi 71 (1): 89-100. https://doi.org/10.33988/auvfd.1063887.
EndNote
Gülaydın A, Alkan İ (January 1, 2024) Evaluation of distal femur fractures in cats by hybrid external fixator. Ankara Üniversitesi Veteriner Fakültesi Dergisi 71 1 89–100.
IEEE
[1]A. Gülaydın and İ. Alkan, “Evaluation of distal femur fractures in cats by hybrid external fixator”, Ankara Univ Vet Fak Derg, vol. 71, no. 1, pp. 89–100, Jan. 2024, doi: 10.33988/auvfd.1063887.
ISNAD
Gülaydın, Ali - Alkan, İsmail. “Evaluation of Distal Femur Fractures in Cats by Hybrid External Fixator”. Ankara Üniversitesi Veteriner Fakültesi Dergisi 71/1 (January 1, 2024): 89-100. https://doi.org/10.33988/auvfd.1063887.
JAMA
1.Gülaydın A, Alkan İ. Evaluation of distal femur fractures in cats by hybrid external fixator. Ankara Univ Vet Fak Derg. 2024;71:89–100.
MLA
Gülaydın, Ali, and İsmail Alkan. “Evaluation of Distal Femur Fractures in Cats by Hybrid External Fixator”. Ankara Üniversitesi Veteriner Fakültesi Dergisi, vol. 71, no. 1, Jan. 2024, pp. 89-100, doi:10.33988/auvfd.1063887.
Vancouver
1.Ali Gülaydın, İsmail Alkan. Evaluation of distal femur fractures in cats by hybrid external fixator. Ankara Univ Vet Fak Derg. 2024 Jan. 1;71(1):89-100. doi:10.33988/auvfd.1063887

Cited By