Research Article

Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA

Volume: 64 Number: 3 September 1, 2017
  • Hüseyin Bilgin Bilgiç
  • Tülin Karagenç
  • Serkan Bakırcı
  • Hasan Eren
  • William Weır
EN TR

Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA

Abstract

In the past three decades, as an alternative to PCR (polymerase chain reaction) new diagnostic techniques like LAMP (loop mediated isothermal amplification) whereby target DNA can be amplified under isothermal conditions without using thermocycler have been developed. The LAMP method allows the synthesis of large amounts of DNA in a short time with high specificity and rapid and easy detection of generated products. In this study, specificity and sensitivity of LAMP method was evaluated for the detection of T. annulata in acute infected and/or carriers cattle using primer pair specifically designed to amplify merozoite surface antigen gene (Mero1), 30 kDa major merozoite surface antigen gene (Tams-1) and cytochrome b gene of T.annulata. Primer pairs with highest sensitivity were used to evaluate the applicability of LAMP to the field samples. Two LAMP primers (CYTOB1 and CYTOB341) targeting cytochrome b gene specifically amplified DNA of different T. annulata isolates successfully while no amplification was seen in other species DNAs and BL20. CYTOB1 primers detected T. annulata Ankara / D7 DNA up to 2 fg, however the detection limit of CYTOB341 was 10 fold lower. The sensitivity of CYTOB1 LAMP assay was same with F3/B3 PCR, however when compared with that of cytob1 PCR a 10fold lower sensitivity was found. The LAMP product was confirmed by restriction digestion and sequencing. Results obtained from this study indicated that none of the designed primer pairs specific to target genes (Tams-1 and Mero1), except cytochrome b gene was able to specifically and sensitively detect different isolates of T. annulata. Consequently, it was shown that LAMP method using CYTOB1 primers is less effective than the cytob1 PCR in terms of detecting T. annulata in the field samples

Keywords

References

  1. Adaszek Ł, Jankowska M, Kalinowski M ve ark. (2013): The loop-mediated isothermal amplification assay for rapid diagnosis of Babesia canis canis infections in dogs. Pol J Vet Sci, 16, 131-3.
  2. Alhassan A, Govind Y, Tam NT ve ark. (2007): Comparative evaluation of the sensitivity of LAMP, PCR and in vitro culture methods for the diagnosis of equine piroplasmosis. Parasitol Res, 100, 1165-1168.
  3. Alhassan A, Thekisoe OM, Yokoyama N ve ark. (2007): Development of loop-mediated isothermal amplification (LAMP) method for diagnosis of equine piroplasmosis. Vet Parasitol, 143, 155-160.
  4. Aonuma H, Suzuki M, Iseki H ve ark. (2008): Rapid identification of Plasmodium carrying mosquitoes using loop- mediated isothermal amplification. Biochem Biophys Res Commun, 376, 671-676.
  5. Bakheit MA, Torra D, Palomino LA ve ark. (2008): Sensitive and specific detection of Cryptosporidium species in PCR-negative samples by loop-mediated isothermal DNA amplification and confirmation of generated LAMP products by sequencing. Vet Parasitol, 158, 11-22.
  6. Bilgic HB, Karagenc T, Shiels B ve ark. (2010): Evaluation of cytochrome b as a sensitive target for PCR based detection of T.annulata carrier animals. Vet Parasitol, 174, 341-347.
  7. Gill P, Ghaemi A (2008): Nucleic acid isothermal amplification Technologies-a review. Nucleos Nucleot Nucl, 27, 224-243.
  8. Guan G, Chauvin A, Luo J ve ark. (2008): The development and evaluation of a loop-mediated isothermal amplification (LAMP) method for detection of Babesia spp. infective to sheep and goats in China. Exp Parasitol, 120, 39-44.

Details

Primary Language

English

Subjects

Veterinary Surgery

Journal Section

Research Article

Authors

Hüseyin Bilgin Bilgiç This is me

Tülin Karagenç This is me

Serkan Bakırcı This is me

Hasan Eren This is me

William Weır This is me

Publication Date

September 1, 2017

Submission Date

September 1, 2017

Acceptance Date

-

Published in Issue

Year 2017 Volume: 64 Number: 3

APA
Bilgiç, H. B., Karagenç, T., Bakırcı, S., Eren, H., & Weır, W. (2017). Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA. Ankara Üniversitesi Veteriner Fakültesi Dergisi, 64(3), 211-221. https://doi.org/10.1501/Vetfak_0000002801
AMA
1.Bilgiç HB, Karagenç T, Bakırcı S, Eren H, Weır W. Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA. Ankara Univ Vet Fak Derg. 2017;64(3):211-221. doi:10.1501/Vetfak_0000002801
Chicago
Bilgiç, Hüseyin Bilgin, Tülin Karagenç, Serkan Bakırcı, Hasan Eren, and William Weır. 2017. “Loop Mediated Isothermal Amplification (LAMP) of Theileria Annulata DNA”. Ankara Üniversitesi Veteriner Fakültesi Dergisi 64 (3): 211-21. https://doi.org/10.1501/Vetfak_0000002801.
EndNote
Bilgiç HB, Karagenç T, Bakırcı S, Eren H, Weır W (September 1, 2017) Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA. Ankara Üniversitesi Veteriner Fakültesi Dergisi 64 3 211–221.
IEEE
[1]H. B. Bilgiç, T. Karagenç, S. Bakırcı, H. Eren, and W. Weır, “Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA”, Ankara Univ Vet Fak Derg, vol. 64, no. 3, pp. 211–221, Sept. 2017, doi: 10.1501/Vetfak_0000002801.
ISNAD
Bilgiç, Hüseyin Bilgin - Karagenç, Tülin - Bakırcı, Serkan - Eren, Hasan - Weır, William. “Loop Mediated Isothermal Amplification (LAMP) of Theileria Annulata DNA”. Ankara Üniversitesi Veteriner Fakültesi Dergisi 64/3 (September 1, 2017): 211-221. https://doi.org/10.1501/Vetfak_0000002801.
JAMA
1.Bilgiç HB, Karagenç T, Bakırcı S, Eren H, Weır W. Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA. Ankara Univ Vet Fak Derg. 2017;64:211–221.
MLA
Bilgiç, Hüseyin Bilgin, et al. “Loop Mediated Isothermal Amplification (LAMP) of Theileria Annulata DNA”. Ankara Üniversitesi Veteriner Fakültesi Dergisi, vol. 64, no. 3, Sept. 2017, pp. 211-2, doi:10.1501/Vetfak_0000002801.
Vancouver
1.Hüseyin Bilgin Bilgiç, Tülin Karagenç, Serkan Bakırcı, Hasan Eren, William Weır. Loop mediated isothermal amplification (LAMP) of Theileria annulata DNA. Ankara Univ Vet Fak Derg. 2017 Sep. 1;64(3):211-2. doi:10.1501/Vetfak_0000002801

Cited By