Objectives: The aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures. Methods: Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients. FPDs were divided into two groups; (1) 3 units and (2) 4 units. Frameworks were layered with e-max Ceram (Ivoclar). A self adhesive luting cement, G-Cem Automix (GC) was used. Restorations were clinically assessed at baseline, 6, 12, 18, 24, 30 months after cementation by using ‘California Dental Association Criteria’, plaque and gingival indexes and patients satisfaction criteria. The marginal and internal adaptation was measured under an optical microscope using silicone replica technique. “Kruskal Wallis” and “Wilcoxon Signed Ranks” tests were used for statistical analysis (p<0.05). Results: No framework fracture was observed. One restoration showed veneer porcelain chipping after 6 months; 2 restorations were debonded at 3rd and 6th months, respectively. The mean marginal gaps were 70.92(±40.02) µm for extended span length Y-TZP FPDs and 88.01(±54.34) µm for short span length Y-TZP FPDs. The highest gap value was observed at the occlusal area and lowest one at the marginal area (p<0.05). There was no significant difference in relation to span length. Conclusion: Regarding all of the clinical evaluation criteria all 34 zirconia FPDs exhibited clinically acceptable scores within an average evaluation time of 18 months. Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area

The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures

Yıl 2014, 2013 Doktora Programı Mezunları Özel Sayısı, 0 - , 13.05.2016

Öz

Objectives: The aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures.
Methods: Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients. FPDs were divided into two groups; (1) 3 units and (2) 4 units. Frameworks were layered with e-max Ceram (Ivoclar). A self adhesive luting cement, G-Cem Automix (GC) was used. Restorations were clinically assessed at baseline, 6, 12, 18, 24, 30 months after cementation by using ‘California Dental Association Criteria’, plaque and gingival indexes and patients satisfaction criteria. The marginal and internal adaptation was measured under an optical microscope using silicone replica technique. “Kruskal Wallis” and “Wilcoxon Signed Ranks” tests were used for statistical analysis (p<0.05). Results: No framework fracture was observed. One restoration showed veneer porcelain chipping after 6 months; 2 restorations were debonded at 3rd and 6th months, respectively. The mean marginal gaps were 70.92(±40.02) μm for extended span length Y-TZP FPDs and 88.01(±54.34) μm for short span length Y-TZP FPDs. The highest gap value was observed at the occlusal area and lowest one at the marginal area (p<0.05). There was no significant difference in relation to span length.

Conclusion: Regarding all of the clinical evaluation criteria all 34 zirconia FPDs exhibited clinically acceptable scores within an average evaluation time of 18 months. Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Articles
Yazarlar

Senem Başbuğ Aydın, Bu kişi benim

Deniz Gemalmaz Bu kişi benim

Yayımlanma Tarihi 13 Mayıs 2016
Gönderilme Tarihi 1 Ekim 2015
Yayımlandığı Sayı Yıl 2014 2013 Doktora Programı Mezunları Özel Sayısı

Kaynak Göster

APA Başbuğ Aydın, S., & Gemalmaz, D. (2016). The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences, 4.
AMA Başbuğ Aydın, S, Gemalmaz D. The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences. Mayıs 2016;4.
Chicago Başbuğ Aydın, Senem, ve Deniz Gemalmaz. “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”. Clinical and Experimental Health Sciences 4, Mayıs (Mayıs 2016).
EndNote Başbuğ Aydın, S, Gemalmaz D (01 Mayıs 2016) The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences 4
IEEE S. Başbuğ Aydın, ve D. Gemalmaz, “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”, Clinical and Experimental Health Sciences, c. 4, 2016.
ISNAD Başbuğ Aydın,, Senem - Gemalmaz, Deniz. “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”. Clinical and Experimental Health Sciences 4 (Mayıs 2016).
JAMA Başbuğ Aydın, S, Gemalmaz D. The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences. 2016;4.
MLA Başbuğ Aydın, Senem ve Deniz Gemalmaz. “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”. Clinical and Experimental Health Sciences, c. 4, 2016.
Vancouver Başbuğ Aydın, S, Gemalmaz D. The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences. 2016;4.

14639   14640