Karşıt Akışlı Ranque– Hilsch Vorteks Tüpünün Makine Öğrenmesi Metotları ile Performans Analizi
Abstract
Keywords
Vorteks Tüp, Makine Öğrenme, Lineer Regresyon, Regresyon Ağaçları, Ağaç Toplulukları
References
- [1] M. Korkmaz, A. Dogan, and V. Kırmacı, “Performance Analysis of Counterflow Ranque – Hilsch Vortex Tube with Linear Regression, Support Vector Machines and Gaussian Process Regression Method,” Gazi J. Eng. Sci., vol. 8, no. 2, pp. 361–370, 2022, doi: doi:10.30855/gmbd.0705015.
- [2] Kırmacı, V, Kaya, H and Cebeci, i, “‘An experimental and exergy analysis of a thermal performance of a counter flow ranque–hilsch vortex tube with different nozzle materials,’” Int. J. Refrig., vol. 85, no. 2018, pp. 240–254, 2018.
- [3] H. Kaya, O. Uluer, E. Kocaoğlu, and V. Kirmaci, “Experimental analysis of cooling and heating performance of serial and parallel connected counterflow Ranquee–Hilsch vortex tube systems using carbon dioxide as a working fluid,” Int. J. Refrig., vol. 106, pp. 297–307, 2019, doi: 10.1016/j.ijrefrig.2019.07.004. LR RA AT DVM Determinasyon Katsayısı (R2) 0,90 0,75 0,92 0,97 Kök Ortalama Kare Hata (RMSE) 3,94 6,20 3,57 2,59 Ortalama Kare Hata (MSE) 15,49 38,48 12,76 6,2 Ortalama Mutlak Hata (MAE) 3,11 5,27 2,82 1,97 449
- [4] W. Fröhlingsdorf and H. Unger, “Numerical investigations of the compressible flow and the energy separation in the Ranque-Hilsch vortex tube,” Int. J. Heat Mass Transf., vol. 42, no. 3, pp. 415–422, 1998, doi: 10.1016/S0017-9310(98)00191-4.
- [5] A. D. Gutak, “Experimental investigation and industrial application of Ranque-Hilsch vortex tube,” Int. J. Refrig., vol. 49, no. 0, pp. 93–98, 2015, doi: 10.1016/j.ijrefrig.2014.09.021.
- [6] N. Bej and K. P. Sinhamahapatra, “Exergy analysis of a hot cascade type Ranque-Hilsch vortex tube using turbulence model,” Energy Econ., vol. 45, no. 1947, pp. 13–24, 2014, doi: 10.1016/j.ijrefrig.2014.05.020.
- [7] T. Dutta, K. P. Sinhamahapatra, and S. S. Bandyopadhyay, “Numerical investigation of gas species and energy separation in the Ranque-Hilsch vortex tube using real gas model,” Int. J. Refrig., vol. 34, no. 8, pp. 2118–2128, 2011, doi: 10.1016/j.ijrefrig.2011.06.004.
- [8] A. Berber, K. Dincer, Y. Yilmaz, and D. N. Ozen, “Rule-based Mamdani-type fuzzy modeling of heating and cooling performances of counterflow Ranque-Hilsch vortex tubes with different geometric construction for steel,” Energy, vol. 51, pp. 297–304, 2013, doi: 10.1016/j.energy.2013.01.005.
- [9] H. Pouraria and M. R. Zangooee, “Numerical investigation of vortex tube refrigerator with a divergent hot tube,” Energy Procedia, vol. 14, no. 2011, pp. 1554–1559, 2012, doi: 10.1016/j.egypro.2011.12.1132.
- [10] X. Han et al., “The influence of working gas characteristics on energy separation of vortex tube,” Appl. Therm. Eng., vol. 61, no. 2, pp. 171–177, 2013, doi: 10.1016/j.applthermaleng.2013.07.027.