Research Article

Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System

Volume: 27 Number: 1 March 1, 2024
EN

Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System

Abstract

The search for environmentally friendly refrigerants for vapor compression systems has been a significant focus recently due to environmental concerns such as ozone depletion and global warming. In this study, the potential of R1224yd as an alternative refrigerant is investigated. A thermodynamic analysis of a 4-kW air conditioning system is conducted to assess the performance of R1224yd. The system is analyzed from a thermodynamic perspective, and key performance indicators such as the Coefficient of Performance and exergy efficiency. The results are then compared to R245fa and R123. Furthermore, a parametric study is performed to examine the impact of key parameters, such as evaporating and condensing temperatures, on the system's performance. This analysis provides insights into the sensitivity of the system's performance to variations in these parameters. The results indicate that R1224yd is a promising candidate as an environmentally friendly alternative refrigerant compared to R123 and R245fa. Because R1224yd has the lowest environmental impact. It has about 700 kg CO2 indirect emission, but about zero kgCO2 for direct emission. While, based on the thermodynamic results, R1224yd offers better performance compared to R245fa which has 1-3% higher in performance value and exergy efficiency, and has comparable performance to R123. This suggests that R1224yd can be a viable option for the systems, providing improved energy efficiency and lower environmental impact.

Keywords

References

  1. R. Yıldırım, A. Ş. Şahin, and E. Dikmen, “Comparative Energetic, Exergetic, Environmental and Enviroeconomic Analysis of Vapour Compression Refrigeration Systems Using R515B as Substitute for R134a,” International Journal of Thermodynamics, 25(1), 125–133, 2022.
  2. N. Nasruddin, S. Sholahudin, N. Giannetti, and Arnas, “Optimization of a cascade refrigeration system using refrigerant C3H8 in high temperature circuits (HTC) and a mixture of C2H6/CO2 in low temperature circuits (LTC),” Appl Therm Eng, 104, 96–103, 2016.
  3. S. Khatoon and M. N. Karimi, “Thermodynamic analysis of two evaporator vapor compression refrigeration system with low GWP refrigerants in automobiles,” International Journal of Air-Conditioning and Refrigeration., doi: 10.1007/s44189-022-00017-1.
  4. M. U. Siddiqui, et al., “Recent Developments in the Search for Alternative Low-Global-Warming-Potential Refrigerants: A Review,” International Journal of Air-Conditioning and Refrigeration, 28, 03, 2020.
  5. R. M.E Ahamed, J. Hossain and S. Hossain, “A Review On Hydrocarbon (HCs) As An Alternative,” Mechanical Engineering Research Journal, 11, 89–96, 2018.
  6. M. Direk, M. S. Mert, F. Yüksel, and A. Keleşoǧlu, “Exergetic investigation of a R1234yf automotive air conditioning system with internal heat exchanger,” International Journal of Thermodynamics, 21, 103–109, 2018.
  7. H. M. Ariyadi, S. Yamaguchi, and K. Saito, “Assessment of thermal and transport properties of ionic liquids as suitable absorbent for absorption cooling applications,” in IOP Conference Series: Materials Science and Engineering, doi: 10.1088/1757-899X/539/1/012005.
  8. H. M. Ariyadi, N. Giannetti, S. Yamaguchi, and K. Saito, “Comparative analysis of ionic liquids as sorptive media for absorption cooling systems,” in Refrigeration Science and Technology, doi: 10.18462/iir.icr.2019.1033.

Details

Primary Language

English

Subjects

Energy Systems Engineering (Other)

Journal Section

Research Article

Early Pub Date

January 15, 2024

Publication Date

March 1, 2024

Submission Date

June 6, 2023

Acceptance Date

October 8, 2023

Published in Issue

Year 2024 Volume: 27 Number: 1

APA
Aisyah, N., & Ariyadi, H. M. (2024). Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System. International Journal of Thermodynamics, 27(1), 13-21. https://doi.org/10.5541/ijot.1310329
AMA
1.Aisyah N, Ariyadi HM. Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System. International Journal of Thermodynamics. 2024;27(1):13-21. doi:10.5541/ijot.1310329
Chicago
Aisyah, Nyayu, and Hifni Mukhtar Ariyadi. 2024. “Performance Evaluation of R1224yd As Alternative to R123 and R245fa for Vapor Compression Heat Pump System”. International Journal of Thermodynamics 27 (1): 13-21. https://doi.org/10.5541/ijot.1310329.
EndNote
Aisyah N, Ariyadi HM (March 1, 2024) Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System. International Journal of Thermodynamics 27 1 13–21.
IEEE
[1]N. Aisyah and H. M. Ariyadi, “Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System”, International Journal of Thermodynamics, vol. 27, no. 1, pp. 13–21, Mar. 2024, doi: 10.5541/ijot.1310329.
ISNAD
Aisyah, Nyayu - Ariyadi, Hifni Mukhtar. “Performance Evaluation of R1224yd As Alternative to R123 and R245fa for Vapor Compression Heat Pump System”. International Journal of Thermodynamics 27/1 (March 1, 2024): 13-21. https://doi.org/10.5541/ijot.1310329.
JAMA
1.Aisyah N, Ariyadi HM. Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System. International Journal of Thermodynamics. 2024;27:13–21.
MLA
Aisyah, Nyayu, and Hifni Mukhtar Ariyadi. “Performance Evaluation of R1224yd As Alternative to R123 and R245fa for Vapor Compression Heat Pump System”. International Journal of Thermodynamics, vol. 27, no. 1, Mar. 2024, pp. 13-21, doi:10.5541/ijot.1310329.
Vancouver
1.Nyayu Aisyah, Hifni Mukhtar Ariyadi. Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System. International Journal of Thermodynamics. 2024 Mar. 1;27(1):13-21. doi:10.5541/ijot.1310329