Abstract

The present study includes a numerical assessment of air-cooling by EAHE (i.e., Earth to Air Heat Exchanger) on hot days in Baghdad city. EAHE consists of pipes buried in a certain depth in the soil, where the temperature is moderate throughout the year. The effect of different input air temperatures at day and night on the EAHE performance has been studied, taking into account the change in soil temperature due to continuous passing of hot air causing an increase in soil temperature and lowers its cooling capacity. In Baghdad (i.e. capital of Iraq), the hot days are extended from mid-April to mid-October. During these months, the weather is characterized by the high solar intensity at day with a daily range exceeding 15 ͦ C. Ambient air temperature varies greatly through spring, summer, and autumn. The various ambient temperatures recorded and documented for Baghdad are used as the inlet temperatures of EAHE in the present study. Besides, the pressure drops and power losses through pipes have been studied, too. The simulated results indicates that the use of EAHE gives the accepted outlet temperature for space cooling (about 26 ℃) on hot days of spring and autumn. In addition, the decrease of ambient temperature less than soil temperature at night leads to lessening the heat storage in soil.

Keywords

References

  1. [1] Gooroochurn, M., Mungur, M., Shamachurn H., Surnam, B. Y. R., Mandarkhan, F., & Bhoodoo, D., Investigation of the performance of ground-coupled heat exchanger technology for tempering air. Journal of Energy Systems 2022; 6(2): 309-321, DOI: 10.30521/jes.1058233
  2. [2] Lattieff FA, Atiya MA, Lateef RA, Dulaimi A, Jweeg MJ, Abed AM, Mahdi JM and Talebizadehsardari P (2022), Thermal analysis of horizontal earth-air heat exchangers in a subtropical climate: An experimental study. Front. Built Environ. 8:981946. doi: 10.3389/fbuil.2022.981946.
  3. [3] Sehli A, Hasni A, Tamali M. The potential of earth-air heat exchangers for low energy cooling of buildings in South Algeria. Energy Procedia. 2012;18:496–506.
  4. [4] Mihalakakou G, Santamouris M, Asimakopoulos D. On the cooling potential of earth to air heat exchangers. Energy Convers Manag. 1994 May 1;35(5):395–402.
  5. [5] Mihalakakou G, Lewis JO, Santamouris M. The influence of different ground covers on the heating potential of earth-to-air heat exchangers. Renew Energy. 1996 Jan 1;7(1):33–46.
  6. [6] Ahmed SF, Amanullah MTO, Khan MMK, Rasul MG, Hassan NMS. Parametric study on thermal performance of horizontal earth pipe cooling system in summer. Energy Convers Manag. 2016 Apr 15;114:324–37.
  7. [7] Rouag A, Benchabane A, Mehdid CE. Thermal design of Earth-to-Air Heat Exchanger. Part I a new transient semi-analytical model for determining soil temperature. J Clean Prod. 2018 May 1;182:538–44.
  8. [8] Mehdid, C.E.; Benchabane, A.; Rouag, A.; Moummi, N.; Melhegueg, M.A.; Moummi, A.; Benabdi, M.L.; Brima, A. Thermal design of Earth-to-air heat exchanger. Part II a new transient semi-analytical model and experimental validation for estimating air temperature. J. Clean. Prod. 2018, 198, 1536–1544..

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Ali Hussien *
University of Technology-Iraq
0000-0002-2263-486X
Iraq

Early Pub Date

December 12, 2023

Publication Date

December 31, 2023

Submission Date

April 4, 2022

Acceptance Date

August 15, 2023

Published in Issue

Year 2023 Volume: 7 Number: 4

APA
Hussien, A. (2023). Numerical study on ground-air heat exchanger performance in a hot climate under different inlet air temperatures. Journal of Energy Systems, 7(4), 315-326. https://doi.org/10.30521/jes.1097439
AMA
1.Hussien A. Numerical study on ground-air heat exchanger performance in a hot climate under different inlet air temperatures. Journal of Energy Systems. 2023;7(4):315-326. doi:10.30521/jes.1097439
Chicago
Hussien, Ali. 2023. “Numerical Study on Ground-Air Heat Exchanger Performance in a Hot Climate under Different Inlet Air Temperatures”. Journal of Energy Systems 7 (4): 315-26. https://doi.org/10.30521/jes.1097439.
EndNote
Hussien A (December 31, 2023) Numerical study on ground-air heat exchanger performance in a hot climate under different inlet air temperatures. Journal of Energy Systems 7 4 315–326.
IEEE
[1]A. Hussien, “Numerical study on ground-air heat exchanger performance in a hot climate under different inlet air temperatures”, Journal of Energy Systems, vol. 7, no. 4, pp. 315–326, Dec. 2023, doi: 10.30521/jes.1097439.
ISNAD
Hussien, Ali. “Numerical Study on Ground-Air Heat Exchanger Performance in a Hot Climate under Different Inlet Air Temperatures”. Journal of Energy Systems 7/4 (December 31, 2023): 315-326. https://doi.org/10.30521/jes.1097439.
JAMA
1.Hussien A. Numerical study on ground-air heat exchanger performance in a hot climate under different inlet air temperatures. Journal of Energy Systems. 2023;7:315–326.
MLA
Hussien, Ali. “Numerical Study on Ground-Air Heat Exchanger Performance in a Hot Climate under Different Inlet Air Temperatures”. Journal of Energy Systems, vol. 7, no. 4, Dec. 2023, pp. 315-26, doi:10.30521/jes.1097439.
Vancouver
1.Ali Hussien. Numerical study on ground-air heat exchanger performance in a hot climate under different inlet air temperatures. Journal of Energy Systems. 2023 Dec. 31;7(4):315-26. doi:10.30521/jes.1097439

Cited By

Journal of Energy Systems is licensed under CC BY-NC 4.0