Araştırma Makalesi
BibTex RIS Kaynak Göster

Calibration of LR-115 type-II detectors used in radon measurements

Yıl 2017, , 356 - 362, 01.06.2017
https://doi.org/10.16984/saufenbilder.284236

Öz

Solid state nuclear track detectors are often preferred for measurements of radon activity concentration in different
environment for many years. Measurement technique is based on the detection of the alpha tracks on the detector
emitted by radon and some of its short-lived progeny (
218Po ve 214Po). Besides, other radon isotopes, such as 220Rn
(thoron) emit alpha particles that may be formed tracks on detectors. Radon activity concentration is proportional to
the number of the tracks on the detector. In the measurements, it is required to express the tracks on the detector
formed by radon and its products in terms of activity unit. In this study, LR-115 Type-II solid state nuclear track etch
detectors used in Physics Department of Sakarya University for the measurements of radon activity concentration in
environmental samples have been calibrated. The calibration factor for the detectors is calculated to be 0.0514
trackcm-2Bq-1m3d-1.  

Kaynakça

  • [1] UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation Sources and effects of ionizing radiation), Sources and effects of ionizing radiation. New York, USA: United Nations Publication, 2000, pp. 1–287.
  • [2] E. Tabar and H. Yakut, "Radon measurements in water samples from the thermal springs of Yalova basin, Turkey,"
  • . J. Radioannal. Nucl. Chem., 299(1), pp. 311–319, 2014.
  • [3] C. Papastefanou, "An overview of instrumentantion for measuring radon in soil gas and groundwaters," J. Environ. Radioact., 63, pp. 271–283, 2002.
  • [4] E. Tabar, "Dikili ve Bergama Bölgelerindeki Tektonik Aktivitenin Jeotermal Sularda Radon Ölçümleri ile Değerlendirilmesi," Y.L. tezi, Nükleer Bilimler Enstitüsü, Ege Üniversitesi, İzmir, Türkiye, 2010.
  • [5] G. Yaprak, O. Kaya; O. Candan, İ. Batmaz, F. Gür, B. Camgöz, "Aktif Gediz grabeninde yer alan Alasehir/Manisa yöresinde tektonik aktiviteye dayalı radon anomalilerinin incelenmesi", Nükleer Bilimler Enstitüsü, Ege Üniversitesi, TÜBİTAK projesi, 100Y059, 2003.
  • [6] R.L. Fleisher, P.B. Price, R.M. Walker, Nuclear tracks in solids: Principles and applications. California, USA: University of California Press, 1975, pp. 1–626 p.
  • [7] S.A. Durrani and R. Ilic, Radon Measurements Etched Track Detectors Applications in Radiation Protection, Earth Sciences and the Environment. London, UK: World Scientific Publishing, 1997, pp. 1–416.
  • [8] S.A. Durrani and R.K. Bull, Solid-State Nuclear Detection; Principles, Methods, and Applications. Oxford, UK: Pergamon Press, 1987, pp. 1–304.

Radon Ölçümünde Kullanılan Lr-115 Tip-II Detektörlerinin Kalibrasyonu

Yıl 2017, , 356 - 362, 01.06.2017
https://doi.org/10.16984/saufenbilder.284236

Öz

Katıhal nükleer iz film dedektörleri uzun yıllardan beri farklı ortamlardaki radon aktivite konsantrasyonun
ölçümünde sıklıkla tercih edilmektedir. Ölçüm tekniği radon ve bazı kısa yarı ömürlü (
218Po ve 214Po) ürünlerinin
yaydıkları alfa parçacıklarının dedektör üzerinde bıraktığı izlerin tespitine dayanmaktadır. Ayrıca
220Rn (toron) gibi
bazı radon izotopları da alfa parçacığı yaymaktadır ve bu alfalar da dedektör üzerinde iz oluşturabilir. Dedektör
üzerinde oluşan izlerin sayısı radon aktivite konsantrasyonu ile orantılıdır. Yapılan ölçümlerde radon ve ürünlerinin
dedektör üzerinde oluşturduğu izlerin aktivite biriminde ifade edilebilmesi için dedektörlerin kalibrasyonu
gerekmektedir. Bu çalışmada Sakarya Üniversitesi Fizik Bölümünde çevresel örneklerde radon aktivite
konsantrasyonu ölçümlerinde kullanılan LR-115 Tip-II katıhal nükleer iz dedektörlerinin kalibrasyon işlemi
gerçekleştirilmiştir. Kullanılan dedektörler için kalibrasyon faktörü 0,0514
izcm-2Bq-1m3gün-1 olarak hesaplanmıştır.  

Kaynakça

  • [1] UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation Sources and effects of ionizing radiation), Sources and effects of ionizing radiation. New York, USA: United Nations Publication, 2000, pp. 1–287.
  • [2] E. Tabar and H. Yakut, "Radon measurements in water samples from the thermal springs of Yalova basin, Turkey,"
  • . J. Radioannal. Nucl. Chem., 299(1), pp. 311–319, 2014.
  • [3] C. Papastefanou, "An overview of instrumentantion for measuring radon in soil gas and groundwaters," J. Environ. Radioact., 63, pp. 271–283, 2002.
  • [4] E. Tabar, "Dikili ve Bergama Bölgelerindeki Tektonik Aktivitenin Jeotermal Sularda Radon Ölçümleri ile Değerlendirilmesi," Y.L. tezi, Nükleer Bilimler Enstitüsü, Ege Üniversitesi, İzmir, Türkiye, 2010.
  • [5] G. Yaprak, O. Kaya; O. Candan, İ. Batmaz, F. Gür, B. Camgöz, "Aktif Gediz grabeninde yer alan Alasehir/Manisa yöresinde tektonik aktiviteye dayalı radon anomalilerinin incelenmesi", Nükleer Bilimler Enstitüsü, Ege Üniversitesi, TÜBİTAK projesi, 100Y059, 2003.
  • [6] R.L. Fleisher, P.B. Price, R.M. Walker, Nuclear tracks in solids: Principles and applications. California, USA: University of California Press, 1975, pp. 1–626 p.
  • [7] S.A. Durrani and R. Ilic, Radon Measurements Etched Track Detectors Applications in Radiation Protection, Earth Sciences and the Environment. London, UK: World Scientific Publishing, 1997, pp. 1–416.
  • [8] S.A. Durrani and R.K. Bull, Solid-State Nuclear Detection; Principles, Methods, and Applications. Oxford, UK: Pergamon Press, 1987, pp. 1–304.
Toplam 9 adet kaynakça vardır.

Ayrıntılar

Konular Metroloji,Uygulamalı ve Endüstriyel Fizik
Bölüm Araştırma Makalesi
Yazarlar

Emre Tabar Bu kişi benim

Yayımlanma Tarihi 1 Haziran 2017
Gönderilme Tarihi 18 Ekim 2016
Kabul Tarihi 20 Aralık 2016
Yayımlandığı Sayı Yıl 2017

Kaynak Göster

APA Tabar, E. (2017). Calibration of LR-115 type-II detectors used in radon measurements. Sakarya University Journal of Science, 21(3), 356-362. https://doi.org/10.16984/saufenbilder.284236
AMA Tabar E. Calibration of LR-115 type-II detectors used in radon measurements. SAUJS. Haziran 2017;21(3):356-362. doi:10.16984/saufenbilder.284236
Chicago Tabar, Emre. “Calibration of LR-115 Type-II Detectors Used in Radon Measurements”. Sakarya University Journal of Science 21, sy. 3 (Haziran 2017): 356-62. https://doi.org/10.16984/saufenbilder.284236.
EndNote Tabar E (01 Haziran 2017) Calibration of LR-115 type-II detectors used in radon measurements. Sakarya University Journal of Science 21 3 356–362.
IEEE E. Tabar, “Calibration of LR-115 type-II detectors used in radon measurements”, SAUJS, c. 21, sy. 3, ss. 356–362, 2017, doi: 10.16984/saufenbilder.284236.
ISNAD Tabar, Emre. “Calibration of LR-115 Type-II Detectors Used in Radon Measurements”. Sakarya University Journal of Science 21/3 (Haziran 2017), 356-362. https://doi.org/10.16984/saufenbilder.284236.
JAMA Tabar E. Calibration of LR-115 type-II detectors used in radon measurements. SAUJS. 2017;21:356–362.
MLA Tabar, Emre. “Calibration of LR-115 Type-II Detectors Used in Radon Measurements”. Sakarya University Journal of Science, c. 21, sy. 3, 2017, ss. 356-62, doi:10.16984/saufenbilder.284236.
Vancouver Tabar E. Calibration of LR-115 type-II detectors used in radon measurements. SAUJS. 2017;21(3):356-62.

30930 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.