Investigating the problems associated with interior air quality of bedroms in boarding schools and developing a new system
Abstract
The problems associated with interior air quality in the dormitory of a vocational and technical training center that consist of six bedrooms with a capacity of sixty students are studied for December of 2016. Measurements are carried out with 11 Testo 535 CO2 measuring instruments, two and nine of which are used for exterior and interior air, respectively. The outdoor CO2 measurements are made in the garden and in front of open window situated at the second floor of the building. The data received from other nine measuring instruments placed at five different locations where the students are mostly present are recorded continuously and averaged manually. These measurements are conducted for seven different hours of four different days on December (1500, 1600, 1800, 2000, 2200, 0000, 0300, 0630). According to results obtained at 1500, it is found that the amount of CO2 level in rooms is measured to 1100 ppm, which is under the permitted amount of level. Students begin to enter the bedrooms from 1800, the amount of CO2 increase staidly to up to 2000. The free time of students from 930 to 2200 increases the amount of CO2 and continues until 0600 in the morning due to their increased activities in this period of times. To solve the problem associated with interior air quality of this dormitory, a novel system which controls the interior air quality continuously and keeps it stabile is developed. In this newly developed system, it is aimed to keep the amount of CO2 at 1100 ppm level by transferring the data collected from CO2 sensors in bedrooms to ABB brand driver, and designing a variable air flow system that controls the fresh air and exhaust fans. This system is also expected to constantly stabilize the blown air temperature at 25 °C by activating the electric resistances present in the air channel according to the load, when the outside air temperature drops below 20 °C.
Keywords
References
- [1] ÖZTÜRK, M., GÜVENSAN, A., YÜCEL, E.“İç Mekanlardaki Kirlilik Sorunu ve Bitkilerin Rolü,” Yanma ve Hava Kirliliği İkinci Ulusal Sempozyumu, Anadolu Üniversitesi 1994, s.287-295.
- [2] ANNESI MAESANO, I. "Indoor Air Qualitiy and Sources in Schools and Related Health Effects,” Journal of Toxicology and Environmental Health-Part B-Critical Reviews, 16, 491-550, 2013.
- [3] ASHRAE, “Standard 62- 1989- Ventilation for Acceptable Indoor Air Quality,” American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, 1989.
- [4] ASHRAE, “Standard 62- 2001- Ventilation for Acceptable Indoor Air Quality,” American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, 2001.
- [5] ASHRAE, “Standard 62.1-2007 user's manual,” Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, 2007.
- [6] SCHRAMEK, E., “Recknagel-Sprenger Schramek - Isıtma ve Klima Tekniği El Kitabı,” TTMD, Ankara. 1999.
- [7] MONTGOMERY, D.D., KALMAN, D.A., “Indoor/Outdoor Air Quality”: Reference Pollutant Concentrations in Complaint-Free Residences, Applied Industrial Hygiene, 4 ,17-20, 1988.
- [8] KREIDER, J.F., RABL, A., “Heating and Cooling of Buildings-Design for Efficiency,” McGraw-Hill Inc., 1994.
Details
Primary Language
English
Subjects
Mechanical Engineering
Journal Section
Research Article
Authors
Mustafa Ertürk
BALIKESİR ÜNİVERSİTESİ
Türkiye
Publication Date
October 1, 2017
Submission Date
March 27, 2017
Acceptance Date
April 1, 2017
Published in Issue
Year 2017 Volume: 21 Number: 5
Cited By
Kullanıcı Memnuniyetinin Konfor Koşulları Açısından Değerlendirilmesi: Kapalı Spor Salonları
KAPU Trakya Mimarlık ve Tasarım Dergisi
https://doi.org/10.70370/kapu.1593966