Seismic Response of Anchorage Elements Used in Curtain Wall Systems
Abstract
Utilizing curtain wall systems as outer covering of a building has been enormously increasing for the last years. Past earthquakes have revealed the wrong design of curtain wall systems connections that can seriously endangers human life. In this study, design procedures proposed by different international and national earthquake codes and specifications to compute the forces in the connection of curtain wall systems are summarized. As a real example, a regular 30-storey reinforced concrete building is considered, and a Finite Element Model is created for this structure. A detailed model for the building and the curtain wall systems and their connection anchors are considered. The axial and shear forces in the anchors are computed using the average results of seven sets of time history analyses. The results are compared with the results of building model using spectrum modal combination analyses and the forces in the connection anchors are proposed by different Specifications; Turkish Earthquake Code 2007, Turkish Earthquake Code 2018, Federal Emergency Management Agency, European Standard. As a result, it can be concluded that the seismic forces used for the design of anchors of the curtain wall systems are better estimated by the specification suggested by Turkish Earthquake Code 2007 compared to the detailed model results.
Keywords
References
- [1] Naggatz, S.G. and S.F. Sinusas, Water Leakage Testing of Glass and Metal Curtain Walls. Building Walls Subject to Water Intrusion and Accumulation: Lessons from the Past and Recommendations for the Future, 2014. 1549: p. 143-165.
- [2] Hitchcock, P.A., et al., The effects of topography on local wind-induced pressures of a medium-rise building. Wind and Structures, 2010. 13(5): p. 433-449.
- [3] Hossain, M.F., Design and construction of ultra-relativistic collision PV panel and its application into building sector to mitigate total energy demand. Journal of Building Engineering, 2017. 9: p. 147-154.
- [4] Maneetes, H. and A.M. Memari, Development of analytical modeling for an energy-dissipating cladding panel. Structural Engineering and Mechanics, 2009. 32(5): p. 587-608.
- [5] Dhakal, R.P., et al., Seismic performance of non-structural components and contents in buildings: an overview of NZ research. Earthquake Engineering and Engineering Vibration, 2016. 15(1): p. 1-17.
- [6] Baniotopoulos, C.C., T.N. Nikolaidis, and G. Moutsanidis, Optimal structural design of glass curtain-wall systems. Proceedings of the Institution of Civil Engineers-Structures and Buildings, 2016. 169(6): p. 450-457.
- [7] Baird, A., A. Palermo, and S. Pampanin, Facade damage assessment of concrete buildings in the 2011 Christchurch earthquake. Structural Concrete, 2012. 13(1): p. 3-13.
- [8] Lu, W.S., et al., Acceleration demand of the outer-skin curtain wall system of the Shanghai Tower. Structural Design of Tall and Special Buildings, 2017. 26(5): p. 14.
Details
Primary Language
English
Subjects
Civil Engineering
Journal Section
Research Article
Publication Date
August 1, 2020
Submission Date
July 27, 2018
Acceptance Date
October 17, 2019
Published in Issue
Year 2020 Volume: 24 Number: 4