Research Article

Smart Touch Voltage Limitation

Volume: 25 Number: 2 April 15, 2021
EN

Smart Touch Voltage Limitation

Abstract

In modern railway electric infrastructure design there are two major concerns that should be considered as touch voltage and stray current. The first problem is touch and step voltage which endangers human safety even to deathly situations. Second problem is stray current which leads to corrosion of metallic infrastructure. Since human safety has higher priority early on railway systems has grounded the rail voltage to the earth but this caused stray current problem. Thus these two problems should be handled together. In this paper we present a touch voltage control and stray current monitoring solution to handle both problems. Our solution presented here uses thyristor based grounding to limit touch voltage and monitor and report stray current

Keywords

References

  1. Referans1 M.Niasati, A.Gholami, “Overview of Stray Current Control in DC Railway Systems” April 2008
  2. Referans2 S.Acıkbas, M.T.Soylemez, ”Catenary System Paralleling and its Effect on Power Consumption and Regenerated Energy Recuperation”, 4th International Conference on Electrical and Electronics Engineering (ELECO 2005), Bursa, Turkey, pp 17-21, 2005.
  3. Referans3 IEEE Std 81-1983, IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System.
  4. Referans4 K.S. Bahra, R.B. Catlow. “Control of Stray Currents for D.C. Traction Power Systems”, Electrical Railways in a United Europe, pp. 136-142, 1995.
  5. Referans5 D. Paul. “DC Traction Power System Grounding”, IEEE Transactions on Industry Applications, vol. 38, no 3, 2002
  6. Referans6 IEEE-SA Standard Boards 2000, IEEE Guide for Safety in AC Substation Grounding, IEEE Std 80-2000, IEEE Incorporate
  7. Referans7 Sakis Meliopoulos, A. P., Patel Shashi, Cokkinides, G. J., “A New Method and Instrument for Touch and Step Voltage Measurements”, IEEE Transactions on Power Delivery, vol. 9, No. 4, October 1994, pp. 1850-1860
  8. Referans8 IEEE Incorporate. . Romulad K., Mukhedar D., “Field Measurement of Touc h and Step Voltages”, IEEE Transaction on Power Apparatus and System Voltages,vol.PAS-103, No.11, November 1984, pp.3286-3294

Details

Primary Language

English

Subjects

Electrical Engineering

Journal Section

Research Article

Publication Date

April 15, 2021

Submission Date

October 19, 2020

Acceptance Date

December 20, 2020

Published in Issue

Year 2021 Volume: 25 Number: 2

APA
Turhan, M. (2021). Smart Touch Voltage Limitation. Sakarya University Journal of Science, 25(2), 547-553. https://doi.org/10.16984/saufenbilder.812423
AMA
1.Turhan M. Smart Touch Voltage Limitation. SAUJS. 2021;25(2):547-553. doi:10.16984/saufenbilder.812423
Chicago
Turhan, Mahmut. 2021. “Smart Touch Voltage Limitation”. Sakarya University Journal of Science 25 (2): 547-53. https://doi.org/10.16984/saufenbilder.812423.
EndNote
Turhan M (April 1, 2021) Smart Touch Voltage Limitation. Sakarya University Journal of Science 25 2 547–553.
IEEE
[1]M. Turhan, “Smart Touch Voltage Limitation”, SAUJS, vol. 25, no. 2, pp. 547–553, Apr. 2021, doi: 10.16984/saufenbilder.812423.
ISNAD
Turhan, Mahmut. “Smart Touch Voltage Limitation”. Sakarya University Journal of Science 25/2 (April 1, 2021): 547-553. https://doi.org/10.16984/saufenbilder.812423.
JAMA
1.Turhan M. Smart Touch Voltage Limitation. SAUJS. 2021;25:547–553.
MLA
Turhan, Mahmut. “Smart Touch Voltage Limitation”. Sakarya University Journal of Science, vol. 25, no. 2, Apr. 2021, pp. 547-53, doi:10.16984/saufenbilder.812423.
Vancouver
1.Mahmut Turhan. Smart Touch Voltage Limitation. SAUJS. 2021 Apr. 1;25(2):547-53. doi:10.16984/saufenbilder.812423


INDEXING & ABSTRACTING & ARCHIVING

33418 33537  30939     30940 30943 30941  30942  33255    33253  33254

30944  30945  30946   34239




30930Bu eser Creative Commons Atıf-Ticari Olmayan 4.0 Uluslararası Lisans   kapsamında lisanslanmıştır .