BibTex RIS Kaynak Göster

Knee Arthroplasty Bone Model with Double Layer Array Synthesis and Evaluation of Finite Element Analysis

Yıl 2012, Cilt: 16 Sayı: 3, 189 - 194, 01.06.2012

Öz

Kaynakça

  • Baldwin M.A., Clary C.W., Fitzpatrick C.K., Deacy J.S., Maletsky L.P. and Rullkoetter P.J., Dynamicfiniteelement knee simulation for evaluation of knee replacement mechanics, Journal of Biomechanics, 2012, Vol. 45, p. 474-483.
  • Bougherara H., Mahboob Z., Miric M. and Youssef M., Finite Element Investigation of Hybrid and Conventional Knee Implants, International Journal of Engineering, 2009, Vol. 3, p. 257-266.
  • Chang T.W., Yang C.T., Liu Y.L., Chen W.C., Lin K.J., Lai Y.S., Huang C.H., Lu Y.C. and Cheng C.K., Biomechanical evaluation of proximal tibial behavior following unicondylar knee arthroplasty: Modified resected surface with corresponding surgical technique, Medical Engineering & Physics, 2011, Vol. 33, p. 1175-1182.
  • Chong D.Y.R., Hansen U.N., Venne R., Verdonschot N. and Amis A.A., The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement, Journal of Biomechanics, 2011, Vol. 44, p. 948-954.
  • Heever D.J., Scheffer C., Erasmus P. and Dillon E., Contactstresses in apatient-specific unicompartmental knee replacement, Clinical Biomechanics, 2011, Vol. 26, p. 159-166.
  • Rho J.Y., Hobatho M.C. and Ashman R.B., Relations of Mechanical Properties to Density and CT Numbers in Human Bone, Med Engng Phys, 1995, Vol. 17, p. 347–55.
  • Villa T., Migliavacca F., Gastaldi D., Colombo M. and Pietrabissa R., Contactstresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations, Journal of Biomechanics, 2004, Vol. 37, p. 45-53.

Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi

Yıl 2012, Cilt: 16 Sayı: 3, 189 - 194, 01.06.2012

Öz

Başarılı protez tasarımları, vücudun gerçek anatomisine en yakın kemik modeli ile elde edilebilir. Bu amaçla, tasarımların doğruluğunu artırmak için kişiye özel protez tasarımlarında kortikal ve trabekükler kemik katmanları dikkate alan modeller kullanılmalıdır. Bu çalışmada 65 yaşındaki bir hastanın diz eklemine ait bilgisayarlı tomografi (BT) görüntüleri ile kemik yapısının üç boyutlu (3B) modeli literatürde bulunan pek çok çalışmadan farklı olarak kortikal ve trabeküler kemik katmanları dikkate alınarak modellenmiştir. Metal protez bileşenleri ile kemiğin fiksasyonu için kemik çimentosu kullanılarak diz protezi dizilim modeli elde edilmiştir. Sonlu elemanlar yöntemi ile dize en fazla yük geldiği 45° açıda normal kuvvetler etki ettirilerek analizler gerçekleştirilmiştir. Çalışma sonucunda anatomiye en yakın kemik modeli için elde edilen bulgular değerlendirilmiştir.

Kaynakça

  • Baldwin M.A., Clary C.W., Fitzpatrick C.K., Deacy J.S., Maletsky L.P. and Rullkoetter P.J., Dynamicfiniteelement knee simulation for evaluation of knee replacement mechanics, Journal of Biomechanics, 2012, Vol. 45, p. 474-483.
  • Bougherara H., Mahboob Z., Miric M. and Youssef M., Finite Element Investigation of Hybrid and Conventional Knee Implants, International Journal of Engineering, 2009, Vol. 3, p. 257-266.
  • Chang T.W., Yang C.T., Liu Y.L., Chen W.C., Lin K.J., Lai Y.S., Huang C.H., Lu Y.C. and Cheng C.K., Biomechanical evaluation of proximal tibial behavior following unicondylar knee arthroplasty: Modified resected surface with corresponding surgical technique, Medical Engineering & Physics, 2011, Vol. 33, p. 1175-1182.
  • Chong D.Y.R., Hansen U.N., Venne R., Verdonschot N. and Amis A.A., The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement, Journal of Biomechanics, 2011, Vol. 44, p. 948-954.
  • Heever D.J., Scheffer C., Erasmus P. and Dillon E., Contactstresses in apatient-specific unicompartmental knee replacement, Clinical Biomechanics, 2011, Vol. 26, p. 159-166.
  • Rho J.Y., Hobatho M.C. and Ashman R.B., Relations of Mechanical Properties to Density and CT Numbers in Human Bone, Med Engng Phys, 1995, Vol. 17, p. 347–55.
  • Villa T., Migliavacca F., Gastaldi D., Colombo M. and Pietrabissa R., Contactstresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations, Journal of Biomechanics, 2004, Vol. 37, p. 45-53.
Toplam 7 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Araştırma Makalesi
Yazarlar

İsmail Hakkı Korkmaz Bu kişi benim

İrfan Kaymaz Bu kişi benim

Fatih Medetalibeyolu Bu kişi benim

Ömer Selim Yıldırım Bu kişi benim

Yayımlanma Tarihi 1 Haziran 2012
Gönderilme Tarihi 14 Mart 2014
Yayımlandığı Sayı Yıl 2012 Cilt: 16 Sayı: 3

Kaynak Göster

APA Korkmaz, İ. H., Kaymaz, İ., Medetalibeyolu, F., Yıldırım, Ö. S. (2012). Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi. Sakarya University Journal of Science, 16(3), 189-194. https://doi.org/10.16984/saufbed.33286
AMA Korkmaz İH, Kaymaz İ, Medetalibeyolu F, Yıldırım ÖS. Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi. SAUJS. Aralık 2012;16(3):189-194. doi:10.16984/saufbed.33286
Chicago Korkmaz, İsmail Hakkı, İrfan Kaymaz, Fatih Medetalibeyolu, ve Ömer Selim Yıldırım. “Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi”. Sakarya University Journal of Science 16, sy. 3 (Aralık 2012): 189-94. https://doi.org/10.16984/saufbed.33286.
EndNote Korkmaz İH, Kaymaz İ, Medetalibeyolu F, Yıldırım ÖS (01 Aralık 2012) Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi. Sakarya University Journal of Science 16 3 189–194.
IEEE İ. H. Korkmaz, İ. Kaymaz, F. Medetalibeyolu, ve Ö. S. Yıldırım, “Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi”, SAUJS, c. 16, sy. 3, ss. 189–194, 2012, doi: 10.16984/saufbed.33286.
ISNAD Korkmaz, İsmail Hakkı vd. “Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi”. Sakarya University Journal of Science 16/3 (Aralık 2012), 189-194. https://doi.org/10.16984/saufbed.33286.
JAMA Korkmaz İH, Kaymaz İ, Medetalibeyolu F, Yıldırım ÖS. Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi. SAUJS. 2012;16:189–194.
MLA Korkmaz, İsmail Hakkı vd. “Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi”. Sakarya University Journal of Science, c. 16, sy. 3, 2012, ss. 189-94, doi:10.16984/saufbed.33286.
Vancouver Korkmaz İH, Kaymaz İ, Medetalibeyolu F, Yıldırım ÖS. Çift Katmanlı Kemik Modeli İle Diz Protezi Dizilimi Eldesi Ve Sonlu Elemanlar Analizi İle Değerlendirilmesi. SAUJS. 2012;16(3):189-94.

30930 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.