BibTex RIS Kaynak Göster

Cervical Spine Axial Rotation Goniometer Design

Yıl 2012, Cilt: 16 Sayı: 3, 337 - 341, 01.06.2012

Öz

-

Kaynakça

  • Wang SF, Teng CC, Lin KH. Measurement of cervical range of motion pattern during cyclic neck movement by an ultrasound-based motion system. Manual Therapy 2005:10 68-72.
  • Tamara Prushansky, and Zeevi Dvir. Cervical motion testing: methodology and clinical implications. Journal of Manipulative and Physiological Therapeutics 2008:31(7) 503-508
  • Kelvin Jordan. Assessment of Published Reliability Studies for Cervical Spine Range.of.Motion Measurement Tools. Journal of Manipulative and Physiological Therapeutics. 2000:23(3) 180-195
  • Haynes MJ,Edmondston S. Accuracy and reliabılıty of a new, protractor-based neck goniometer. Journal of Manipulative and Physiological Therapeutics. 2002:25 579-86
  • Morphett AL, Colin M. Crawford, Lee D. The use of electromagnetic tracking technology for measurement of passive cervical range of motion: a pilot study. Journal of Manipulative and Physiological Therapeutics. 2003:26152
  • Agarwal S, Allison G, Kevin PS. Reliability of the spin-t cervical goniometer in measuring cervical range of motion in an asymptomatic indian populatıon. Journal of Manipulative and Physiological Therapeutics. 2005:28,487
  • Agarwal S, Allison G, Kevin PS. Validation of the spin-t goniometer, a cervical range of motion device. Journal of Manipulative and Physiological Therapeutics 2005:28, 604-609
  • Williams MA, Christopher JM, Angeliki C, Matthew WC, Simon G. A systematic review of reliability and validity studies of methods for measuring active and passive cervical range of motion. Journal of Manipulative and Physiological Therapeutics. 2010:33,138-155
  • Youdas JW, Carey JR, Garrett TR. Reliability of measurements of cervical spine range of motion-comparison of three methods. Physical Therapy. 1991:71, 98-104
  • Radcliff K, Rubin T, Reitman CA, Smith J, Kepler C, Hilibrand A. Normal cervical alignment. Seminars in spine surgery. 2011: 23, 159-164
  • Lee H, Nicholson LL, Roger D, Sung S. Proprioception and rotation range sensitization associated with subclinical neck pain. Spine. 2005: 30(3), 60-67
  • Revel M, Andre-Deshays C, Minguet M. Cervicocephalic kinesthetic sensibility in patients with cervical pain. Archives of Physical Medicine and Rehabilitation 1991, 72(5):288-291
  • Golomer E, Guillou E, Testa M, Lecoq C, Ohlmann T. Contribution of neck proprioception to subjective vertical perception among experts in physical activities and untrained women. Neuroscience Letters. 2005: 381(1-2) 31-35

Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı

Yıl 2012, Cilt: 16 Sayı: 3, 337 - 341, 01.06.2012

Öz

To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera). With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measurement of "joint position sense" which is recently has rising interest in researches can be made practically with this goniometer.

Kaynakça

  • Wang SF, Teng CC, Lin KH. Measurement of cervical range of motion pattern during cyclic neck movement by an ultrasound-based motion system. Manual Therapy 2005:10 68-72.
  • Tamara Prushansky, and Zeevi Dvir. Cervical motion testing: methodology and clinical implications. Journal of Manipulative and Physiological Therapeutics 2008:31(7) 503-508
  • Kelvin Jordan. Assessment of Published Reliability Studies for Cervical Spine Range.of.Motion Measurement Tools. Journal of Manipulative and Physiological Therapeutics. 2000:23(3) 180-195
  • Haynes MJ,Edmondston S. Accuracy and reliabılıty of a new, protractor-based neck goniometer. Journal of Manipulative and Physiological Therapeutics. 2002:25 579-86
  • Morphett AL, Colin M. Crawford, Lee D. The use of electromagnetic tracking technology for measurement of passive cervical range of motion: a pilot study. Journal of Manipulative and Physiological Therapeutics. 2003:26152
  • Agarwal S, Allison G, Kevin PS. Reliability of the spin-t cervical goniometer in measuring cervical range of motion in an asymptomatic indian populatıon. Journal of Manipulative and Physiological Therapeutics. 2005:28,487
  • Agarwal S, Allison G, Kevin PS. Validation of the spin-t goniometer, a cervical range of motion device. Journal of Manipulative and Physiological Therapeutics 2005:28, 604-609
  • Williams MA, Christopher JM, Angeliki C, Matthew WC, Simon G. A systematic review of reliability and validity studies of methods for measuring active and passive cervical range of motion. Journal of Manipulative and Physiological Therapeutics. 2010:33,138-155
  • Youdas JW, Carey JR, Garrett TR. Reliability of measurements of cervical spine range of motion-comparison of three methods. Physical Therapy. 1991:71, 98-104
  • Radcliff K, Rubin T, Reitman CA, Smith J, Kepler C, Hilibrand A. Normal cervical alignment. Seminars in spine surgery. 2011: 23, 159-164
  • Lee H, Nicholson LL, Roger D, Sung S. Proprioception and rotation range sensitization associated with subclinical neck pain. Spine. 2005: 30(3), 60-67
  • Revel M, Andre-Deshays C, Minguet M. Cervicocephalic kinesthetic sensibility in patients with cervical pain. Archives of Physical Medicine and Rehabilitation 1991, 72(5):288-291
  • Golomer E, Guillou E, Testa M, Lecoq C, Ohlmann T. Contribution of neck proprioception to subjective vertical perception among experts in physical activities and untrained women. Neuroscience Letters. 2005: 381(1-2) 31-35
Toplam 13 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Araştırma Makalesi
Yazarlar

Emin Ulaş Erdem Bu kişi benim

Filiz Can Bu kişi benim

Yayımlanma Tarihi 1 Haziran 2012
Gönderilme Tarihi 14 Mart 2014
Yayımlandığı Sayı Yıl 2012 Cilt: 16 Sayı: 3

Kaynak Göster

APA Erdem, E. U., & Can, F. (2012). Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı. Sakarya University Journal of Science, 16(3), 337-341. https://doi.org/10.16984/saufbed.58560
AMA Erdem EU, Can F. Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı. SAUJS. Aralık 2012;16(3):337-341. doi:10.16984/saufbed.58560
Chicago Erdem, Emin Ulaş, ve Filiz Can. “Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı”. Sakarya University Journal of Science 16, sy. 3 (Aralık 2012): 337-41. https://doi.org/10.16984/saufbed.58560.
EndNote Erdem EU, Can F (01 Aralık 2012) Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı. Sakarya University Journal of Science 16 3 337–341.
IEEE E. U. Erdem ve F. Can, “Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı”, SAUJS, c. 16, sy. 3, ss. 337–341, 2012, doi: 10.16984/saufbed.58560.
ISNAD Erdem, Emin Ulaş - Can, Filiz. “Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı”. Sakarya University Journal of Science 16/3 (Aralık 2012), 337-341. https://doi.org/10.16984/saufbed.58560.
JAMA Erdem EU, Can F. Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı. SAUJS. 2012;16:337–341.
MLA Erdem, Emin Ulaş ve Filiz Can. “Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı”. Sakarya University Journal of Science, c. 16, sy. 3, 2012, ss. 337-41, doi:10.16984/saufbed.58560.
Vancouver Erdem EU, Can F. Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı. SAUJS. 2012;16(3):337-41.

30930 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.