This study is included the initial findings of comprehensive research project on mechanical properties of mortar with boron modified active belite cement (BAB) and resistance effectivity against corrosion of steel reinforcing bar embedded BAB cement mortar. The compressive and flexural strength tests conducted to determine the mechanical properties of mortar specimens having dimension of 40x40x160 mm in the investigation. Besides, the electrochemical tests applied on the cylindrical specimens having dimension of φ50x100 mm at the ending of exposed to 5% NaCl solution for 60 days. Five specimens were produced for every test on two trial groups. According to the findings, as the mortar specimens with BAB cement have compressive strength of 14.5 MPa, those of mortar included CEM I 42.5 is 26.8 MPa in average. It found that the mean compressive strength values of mortars with BAB cement or CEM I 42.5 were 55.2 and 50.0 MPa at the age of 28 days, with respectively. At the ending of electrochemical test duration, the reinforcing steel bar embedded mortar specimens produced with two types cement exhibited similar results each other. Corrosion current of mortar specimens with BAB cement or CEM I 42.5 cement have mean values of 3.06 µA/cm2 and 3.87 µA/cm2 , corrosion rates of those were 1,41 mpy and 1,79 mpy, polarisation resistance values were 1,45 kOhm and 1,35 kOhm, with respectively. At the ending of 60 days, Ecor mean values optained from mortar specimens with BAB cement or CEM I 42.5 cement were -311 and -304 mV, with respectively. In general, according to the results, there was no superiority of CEM I 42.5 cement mortar from BAB cement mortar from the point of view of effectivity of resistance against rebar corrosion at the ending of exposed to 5% NaCl solution for 60 days.According to the findings, as the mortar specimens with BAB cement have compressive strength of 14.5 MPa, those of mortar included CEM I 42.5 is 26.8 MPa in average. It found that the mean compressive strength values of mortars with BAB cement or CEM I 42.5 were 55.2 and 50.0 MPa at the age of 28 days, with respectively. At the ending of electrochemical test duration, the reinforcing steel bar embedded mortar specimens produced with two types cement exhibited similar results each other. Corrosion current of mortar specimens with BAB cement or CEM I 42.5 cement have mean values of 3.06 µA/cm2 and 3.87 µA/cm2, corrosion rates of those were 1,41 mpy and 1,79 mpy, polarisation resistance values were 1,45 kOhm and 1,35 kOhm, with respectively. At the ending of 60 days, Ecor mean values optained from mortar specimens with BAB cement or CEM I 42.5 cement were -311 and -304 mV, with respectively. In general, according to the results, there was no superiority of CEM I 42.5 cement mortar from BAB cement mortar from the point of view of effectivity of resistance against rebar corrosion at the ending of exposed to 5% NaCl solution for 60 days.
BAB cement mechanical properties reinforcement corrosion electrochemical tests
Bu çalışma, kapsamlı bir araştırma projesi ile borlu aktif belit çimentolu (BAB-TS 13353) harçların mekanik özellikleri ve içerisine gömülü betonarme çeliğinin korozyona karşı korunması etkinliğinin belirlenmesi amacı ile CEM I 42.5 içeren harçlarla karşılaştırılmalı olarak elde edilen ilk bulguları içermektedir. Araştırmada mekanik özelliklerin belirlenmesine yönelik 40x40x160 mm harç çubuğu numuneleri üzerinde 7. ve 28. günlük kür süreçleri sonunda basınç ve eğilme dayanımı testleri uygulanmıştır. Ayrıca φ50x100 mm lik silindirik donatılı harç örnekleri üzerinde korozyon deneyleri için %5 NaCl içeren çözeltiye 60 gün maruz bırakıldıktan sonra elektrokimyasal testler uygulanmıştır. Her deney için iki seride de 5’er numune üretilmiştir. Elde edilen bulgulara göre BAB çimentolu harç örneklerinin basınç dayanımları 7. Günde 14.5 MPa iken CEM I 42.5 içerenlerde ortalama 26.8 MPa bulunmuştur. 28 günlük basınç deneyleri sonucunda BAB çimentolu harçlarda ortalama 55.2 MPa, CEM I çimentoluda ise 50.0 MPa değerleri bulunmuştur. Elektrokimyasal testler sonucunda iki çimento türü ile üretilen betonarme çelik donatılı harç örneklerinin birbirlerine yakın sonuçlar verdikleri görülmüştür. BAB içeren harçlarda 3.06 µA/cm2 korozyon akımı meydana gelirken CEM I 42.5 örneklerinde ortalama 3.87 µA/cm2 olmuştur. Korozyon hızları aynı sıra ile 1,41 mpy ve 1,79 mpy olduğu görülmüştür. Rp değerleri de aynı sıra ile 1,45 kOhm ve 1,35 kOhm olarak hesaplanmıştır. 60 gün sonundaki Ecor değerleri ise sırası ile -311 ve -304 mV olarak belirlenmiştir. Buna göre, genel olarak, 60 günlük %5 NaCl çözeltisinde korozyona maruz bırakılması sonucunda CEM I 42.5 çimentosunun çelik donatıyı korozyona karşı koruma etkinliği bakımından, BAB ile üretilen harç örneklerinden bir üstünlüğü yoktur.
BAB çimentosu mekanik özellikler donatı korozyonu elektrokimyasal testler
Birincil Dil | Türkçe |
---|---|
Konular | Mühendislik |
Bölüm | Araştırma Makalesi |
Yazarlar | |
Yayımlanma Tarihi | 1 Nisan 2015 |
Gönderilme Tarihi | 16 Eylül 2014 |
Kabul Tarihi | 14 Kasım 2014 |
Yayımlandığı Sayı | Yıl 2015 Cilt: 19 Sayı: 1 |
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.