SüleymanDemirel Üniversitesi
TIP FAKÜLTESİ DERGİSİ: 2007 Haziran; 14(2)
Farklı ışık kaynakları ile polimerize edilen kompozit, kompomer ve rezin modifiye cam iyonomer siman materyallerinin su emilimi ve suda çözünürlük düzeylerinin incelenmesi
Çiğdem Küçükeşmen*, D. Derya Öztaş***, H. Cenker Küçükeşmen**, Selim Erkut****
* Süleyman Demirel Üniversitesi, Diş Hekimliği Fakültesi, Pedodonti AD, Isparta
** Ankara Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi AD, Isparta
*** Süleyman Demirel Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi AD, Isparta
**** Başkent Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi AD, Isparta
Özet
Mevcut çalışmanın amacı, halojen ve LED ışık kaynaklarıyla polimerize edilen iki kompozit rezin (Filtek Z-250, Filtek Supreme), iki kompomer (Compoglass F, Dyract AP) ve bir rezin-modifiye cam iyonomer siman (Vitrebond) materyallerinin su emilimi ve suda çözünürlük düzeylerinin incelenmesidir. Örnekler 1mm kalınlığında ve 15mm çapındaki teflon kalıplarda hazırlandı ve üretici firmaların talimatları doğrultusunda farklı ışık kaynaklarıyla polimerize edildi (n=7). ISO 4049 ve ADA No.8 kriterlerine göre su emilimi ve suda çözünürlük testleri uygulandı. 7 gün suda bekletilen örneklerin sabit kütle ağırlıklarındaki değişiklikler, “mikrogram (µg)” olarak ölçüldü, su emilimi ve çözünürlük değerleri “µg/mm3” olarak hesaplandı. İki-yönlü ANOVA ve Duncan çoklu karşılaştırma testleriyle istatistiksel değerlendirme yapıldı. Kompozit ve kompomer materyallerin su emilimi ve çözünürlük değerleri arasında anlamlı farklılık bulunmadı (p>0.05). Cam iyonomer simanla diğer materyaller arasında anlamlı farklılık bulundu (p<0.05). Kompozit ve kompomer materyallerin su emilimi ve çözünürlük düzeyleri arasında, ışık kaynakları bakımından istatistiksel farklılık gözlenmezken (p>0.05), cam iyonomer siman için gözlendi (p<0.05).
Anahtar kelimeler: Kompozit, kompomer, rezin-modifiye cam iyonomer siman, LED ışık kaynağı, su emilimi, suda çözünürlük.
Abstract
The investigation of levels of water sorption and water solubility of composite, compomer and resin modified glass ionomer cement materials polymerized by different light sources.
The aim of this study was to investigate the levels of water sorption and water solubility of two resin composites (Filtek Z-250, Filtek Supreme), two compomers (Compoglass F, Dyract AP) and one resin-modified glass ionomer cement (Vitrebond) polymerized by halogen and LED light sources. Samples were prepared in teflon molds with 1mm high and 15mm diameter and polymerized with different light sources according to the manufacturers' instructions (n=7). Water sorption and solubility tests were based on the ISO 4049 and ADA No.8 requirements. Weight changes of specimens were measured as “microgram (µg)” and calculated as “µg/mm3” after water immersion for 7 days. Data were analysed with two-way ANOVA and Duncan's multiple comparison test. There were not significant differences between composites and compomers according to sorption or solubility (p>0.05). Glass ionomer cement was found significantly different than the other materials (p<0.05). There was no statistically significant difference between light sources according to composites and compomers (p>0.05), but it was found for GIC (p<0.05).
Key words: Composite, compomer, resin modified glass ionomer cement, LED light source, water sorption, water solubility.
Kompozit kompomer rezin-modifiye cam iyonomer siman LED ýþýk kaynaðý su emilimi suda çözünürlük
Primary Language | English |
---|---|
Journal Section | Research Articles |
Authors | |
Publication Date | April 30, 2009 |
Submission Date | April 30, 2009 |
Published in Issue | Year 2007 Volume: 14 Issue: 2 |
Süleyman Demirel Üniversitesi Tıp Fakültesi Dergisi/Medical Journal of Süleyman Demirel University is licensed under Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International.