Research Article

Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey

Volume: 11 Number: 1 March 22, 2021
EN TR

Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey

Abstract

Introduction: In this study, we aimed to investigate how the normal values of optic nerve sheath diameter are distributed in normal healthy volunteers in Turkish population. Materials and Methods: This prospective study was planned between November 15, 2019 and April 15, 2020. The study included 160 healthy volunteers who were over 18 years of age and didn’t have acute and chronic systemic disorders. The optic nerve sheath diameters (ONSD) of the subjects were measured from both eyes ultrasonographically. Results: ONSD means (median, IQR) of right and left eyes of the subjects were measured as 4.87 (0.41) mm and 4.86 (0.32) mm, respectively. Right and left eye ONSD measurements were detected lower in female gender than men, and this difference was statistically significant. (p = 0.017 and p = 0.031, respectively). Conclusion: Determination of ONSD optimal reference values in healthy individuals would benefit in predicting increase in intracranial pressure in clinical practice.

Keywords

Supporting Institution

yok

Project Number

yok

Thanks

Bu çalışmaya katılan sağlıklı gönüllülere en içten teşekkürlerimizi sunuyoruz.

References

  1. 1. Çökük A, Kozacı N, Ay MO, Açıkalın A, Seviner M, Satar S. Acil Servise Başvuran Kafa Travması Olgularının Değerlendirilmesi. Cukurova Medical Journal. 2013;38(1):63-71.
  2. 2. Dölen D, Sabanci PA. Kafa Travmasında Beyin Ödemi ve İntrakranyal Basınç Değişimleri. Türk Nöroşir Derg. 2020;30(2):187-193.
  3. 3. Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008;15(2):201-4.
  4. 4. Emmez ÖH, Egemen E. Kafa içi basınç artışı tedavisinde pratik yaklaşımlar. Yoğun Bakım Derg. 2010; 9(2):77-84.
  5. 5. Harary M, Dolmans RG, Gormley WB. Intracranial pressure monitoring—review and avenues for development. Sensors. 2018;18(2):465.
  6. 6. Changa AR, Czeisler BM, Lord AS. Management of Elevated Intracranial Pressure: a Review. Current neurology and neuroscience reports. 2019;19(12):99.
  7. 7. Chesnut RM, Temkin N, Carney N, Dikmen S, Rondina C, Videtta W, et al. A trial of intracranial-pressure monitoring in traumatic brain injury. N Engl J Med. 2012;367(26):2471-81.
  8. 8. Aiolfi A, Benjamin E, Khor D, Inaba K, Lam L, Demetriades D. Brain trauma foundation guidelines for intracranial pressure monitoring: Compliance and effect on outcome. World J Surg. 2017;41(6):1543-9.

Details

Primary Language

English

Subjects

Health Care Administration

Journal Section

Research Article

Publication Date

March 22, 2021

Submission Date

August 29, 2020

Acceptance Date

January 5, 2021

Published in Issue

Year 2021 Volume: 11 Number: 1

APA
Gökçen, E., Çaltekin, İ., Albayrak, L., Savrun, A., Atik, D., Vural, S., Kılıç, N., Kuşdoğan, M., & Kaya, H. B. (2021). Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey. Sakarya Medical Journal, 11(1), 85-90. https://doi.org/10.31832/smj.787427
AMA
1.Gökçen E, Çaltekin İ, Albayrak L, et al. Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey. Sakarya Medical Journal. 2021;11(1):85-90. doi:10.31832/smj.787427
Chicago
Gökçen, Emre, İbrahim Çaltekin, Levent Albayrak, et al. 2021. “Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey”. Sakarya Medical Journal 11 (1): 85-90. https://doi.org/10.31832/smj.787427.
EndNote
Gökçen E, Çaltekin İ, Albayrak L, Savrun A, Atik D, Vural S, Kılıç N, Kuşdoğan M, Kaya HB (March 1, 2021) Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey. Sakarya Medical Journal 11 1 85–90.
IEEE
[1]E. Gökçen et al., “Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey”, Sakarya Medical Journal, vol. 11, no. 1, pp. 85–90, Mar. 2021, doi: 10.31832/smj.787427.
ISNAD
Gökçen, Emre - Çaltekin, İbrahim - Albayrak, Levent - Savrun, Atakan - Atik, Dilek - Vural, Sevilay - Kılıç, Nuray - Kuşdoğan, Mikail - Kaya, Hasan Burak. “Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey”. Sakarya Medical Journal 11/1 (March 1, 2021): 85-90. https://doi.org/10.31832/smj.787427.
JAMA
1.Gökçen E, Çaltekin İ, Albayrak L, Savrun A, Atik D, Vural S, Kılıç N, Kuşdoğan M, Kaya HB. Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey. Sakarya Medical Journal. 2021;11:85–90.
MLA
Gökçen, Emre, et al. “Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey”. Sakarya Medical Journal, vol. 11, no. 1, Mar. 2021, pp. 85-90, doi:10.31832/smj.787427.
Vancouver
1.Emre Gökçen, İbrahim Çaltekin, Levent Albayrak, Atakan Savrun, Dilek Atik, Sevilay Vural, Nuray Kılıç, Mikail Kuşdoğan, Hasan Burak Kaya. Assesment of Optic Nerve Sheath Diameter in Healthy Adults in Turkey. Sakarya Medical Journal. 2021 Mar. 1;11(1):85-90. doi:10.31832/smj.787427

INDEXING & ABSTRACTING & ARCHIVING


  29985  30950  30951 30954 34273


30703 The published articles in SMJ are licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.