Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones

Yıl 2022, Cilt: 8 Sayı: 2, 249 - 267, 11.03.2022
https://doi.org/10.18186/thermal.1086236

Öz

Thermal insulation is one of the most effective methods of reducing energy consumption in buildings. Therefore, the parameters influencing the optimum insulation thickness are widely investigated. In this study, the optimum insulation thickness is obtained using the life cycle analysis method and the genetic algorithm by considering the size of the heating and cooling systems as an optimization variable, which has not been addressed in the earlier researches. Furthermore, the effect of the climate conditions on the optimum insulation thickness is comprehensively studied using five different climate zones, including Hot-Dry, Cold-Dry, Moderate-Humid, Hot-semi Humid, and Hot-Humid. It is found that the optimum thickness of expanded polystyrene insulation increases between 5%-19% considering the size variation of the heating systems including the central heating system and wall-hung gas boilers. By size variation of the cooling systems including the evaporative cooler and split air conditioner, this increase is between 8-19%. This is because the cost reduction due to the reduction of the required size of the heating and cooling systems can be expended for insulating the building with larger thickness which results in lower energy consumption. Based on the obtained results, the energy cost saving increases between 3.5%-14.5% and also, the payback period decreases about 1 to 3 months, depending on the considered heating and cooling systems and climate zone. The results confirm that the optimum insulation thickness can be determined with significant inaccuracy, ignoring the size variation of the heating and cooling systems as a result of thermal insulation.

Kaynakça

  • The article references can be accessed from the .pdf file.
Yıl 2022, Cilt: 8 Sayı: 2, 249 - 267, 11.03.2022
https://doi.org/10.18186/thermal.1086236

Öz

Kaynakça

  • The article references can be accessed from the .pdf file.
Toplam 1 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Termodinamik ve İstatistiksel Fizik
Bölüm Makaleler
Yazarlar

Maryam Karamı Bu kişi benim 0000-0003-4771-2446

Ehsan Anbarzadeh Bu kişi benim 0000-0003-0522-2502

Shahram Delfanı Bu kişi benim 0000-0002-3077-6366

Yayımlanma Tarihi 11 Mart 2022
Gönderilme Tarihi 7 Eylül 2020
Yayımlandığı Sayı Yıl 2022 Cilt: 8 Sayı: 2

Kaynak Göster

APA Karamı, M., Anbarzadeh, E., & Delfanı, S. (2022). Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering, 8(2), 249-267. https://doi.org/10.18186/thermal.1086236
AMA Karamı M, Anbarzadeh E, Delfanı S. Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering. Mart 2022;8(2):249-267. doi:10.18186/thermal.1086236
Chicago Karamı, Maryam, Ehsan Anbarzadeh, ve Shahram Delfanı. “Effect of HVAC System Size on the Optimum Insulation Thickness of the Buildings in Different Climate Zones”. Journal of Thermal Engineering 8, sy. 2 (Mart 2022): 249-67. https://doi.org/10.18186/thermal.1086236.
EndNote Karamı M, Anbarzadeh E, Delfanı S (01 Mart 2022) Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering 8 2 249–267.
IEEE M. Karamı, E. Anbarzadeh, ve S. Delfanı, “Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones”, Journal of Thermal Engineering, c. 8, sy. 2, ss. 249–267, 2022, doi: 10.18186/thermal.1086236.
ISNAD Karamı, Maryam vd. “Effect of HVAC System Size on the Optimum Insulation Thickness of the Buildings in Different Climate Zones”. Journal of Thermal Engineering 8/2 (Mart 2022), 249-267. https://doi.org/10.18186/thermal.1086236.
JAMA Karamı M, Anbarzadeh E, Delfanı S. Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering. 2022;8:249–267.
MLA Karamı, Maryam vd. “Effect of HVAC System Size on the Optimum Insulation Thickness of the Buildings in Different Climate Zones”. Journal of Thermal Engineering, c. 8, sy. 2, 2022, ss. 249-67, doi:10.18186/thermal.1086236.
Vancouver Karamı M, Anbarzadeh E, Delfanı S. Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones. Journal of Thermal Engineering. 2022;8(2):249-67.

IMPORTANT NOTE: JOURNAL SUBMISSION LINK http://eds.yildiz.edu.tr/journal-of-thermal-engineering