BibTex RIS Cite

The Effect of the Evacuated Tube Collectors on Solar Pond Performance

Year 2014, Volume: 4 Issue: 1, 1 - 10, 27.11.2014

Abstract

The present study deals with the effect of the evacuated tube solar collectors on the heat storage performance of a solar pond. For the experimental work, a solar pond system with a radius of 0.80 m and a depth of 1.60 m and four evacuated tube solar collectors was built in Cukurova University in Adana, Turkey. Heat energy collected by evacuated tube solar collectors was transferred to the solar pond storage zone by using a heat exchanger system. The temperature and density distribution of the system were measured by using thermocouples and hydrometers. Experimental studies were performed by using 1, 2, 3 and 4 evacuated tube solar collectors. As a result, the temperature increases in the solar pond were determined as 1.56, 2.37, 3.45 and 4.01 °C for 1, 2, 3 and 4 collectors, respectively. It is seen that the temperature of the solar pond has increased from 15 °C to 25 °C within four days.

References

  • N. Kılıç, Yenilenebilir Enerji Kaynakları, Ar-Ge Bülten Mart-Sektörel, İzmir Ticaret Odası, 2008.
  • M.A. Ersöz, A. Yıldız, Tesisat Mühendisliği, 2013, 133, 5.
  • M. Karakilcik, I. Dincer, I. Bozkurt, A. Atiz, Energy Convers Manage, 2013, 65, 98. M. Karakilcik, I. Dincer, M.A. Rosen, Appl Thermal Eng, 2006, 26, 727.
  • M. Karakilcik, K. Kıymac, I. Dincer, Int J Heat Mass Transfer, 2006, 49, 825.
  • M. Karakilcik, I. Dincer, Int J Thermal Sciences, 2008, 47, 93.
  • N. Sharma, G. Diaz, Solar Energy, 2011, 85, 881.
  • I. Bozkurt, M. Karakilcik, Solar Energy, 2012, 86, 1611.
  • M. Karakilcik, I. Bozkurt, I. Dincer, Int J Exergy, 2013, 12, 70.
  • I. Bozkurt, A. Atiz, M. Karakilcik, I. Dincer, Int J Green Energy, 2014, 11, 404.

Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi

Year 2014, Volume: 4 Issue: 1, 1 - 10, 27.11.2014

Abstract

Bu çalışma vakum tüplü güneş kollektörlerinin güneş havuzunun ısı depolama performansı üzerine etkisi ile ilgilidir. Deneysel çalışma için, 0.80 m yarıçaplı, 1.60 m derinlikli ve dört vakum tüplü güneş kollektörlü bir güneş havuzu sistemi Çukurova Üniversitesi, Adana, Türkiye’de kurulmuştur. Vakum tüplü güneş kollektörleri tarafından toplanan ısı enerjisi bir ısı değiştirici sistem kullanılarak güneş havuzunun depolama bölgesine transfer edilmiştir. Sistemin sıcaklık ve yoğunluk dağılımları ısıl çiftler ve hidrometreler kullanılarak ölçülmüştür. Deneysel çalışmalar 1, 2, 3 ve 4 vakum tüplü güneş kollektörü kullanılarak gerçekleştirilmiştir. Sonuç olarak, güneş havuzundaki sıcaklık artışları 1, 2, 3 ve 4 kollektör için sırasıyla 1.56, 2.37, 3.45 ve 4.01 °C olarak belirlenmiştir. Güneş havuzunun sıcaklığının dört gün içerisinde 15 °C’den 25 °C’ye kadar arttığı görülmüştür.

References

  • N. Kılıç, Yenilenebilir Enerji Kaynakları, Ar-Ge Bülten Mart-Sektörel, İzmir Ticaret Odası, 2008.
  • M.A. Ersöz, A. Yıldız, Tesisat Mühendisliği, 2013, 133, 5.
  • M. Karakilcik, I. Dincer, I. Bozkurt, A. Atiz, Energy Convers Manage, 2013, 65, 98. M. Karakilcik, I. Dincer, M.A. Rosen, Appl Thermal Eng, 2006, 26, 727.
  • M. Karakilcik, K. Kıymac, I. Dincer, Int J Heat Mass Transfer, 2006, 49, 825.
  • M. Karakilcik, I. Dincer, Int J Thermal Sciences, 2008, 47, 93.
  • N. Sharma, G. Diaz, Solar Energy, 2011, 85, 881.
  • I. Bozkurt, M. Karakilcik, Solar Energy, 2012, 86, 1611.
  • M. Karakilcik, I. Bozkurt, I. Dincer, Int J Exergy, 2013, 12, 70.
  • I. Bozkurt, A. Atiz, M. Karakilcik, I. Dincer, Int J Green Energy, 2014, 11, 404.
There are 9 citations in total.

Details

Primary Language Turkish
Journal Section Research Articles
Authors

İsmail Bozkurt This is me

Ayhan Atız This is me

İsmail Bozkurt This is me

Mehmet Karakılçık This is me

Mehmet Karakılçık This is me

Publication Date November 27, 2014
Published in Issue Year 2014 Volume: 4 Issue: 1

Cite

APA Bozkurt, İ., Atız, A., Bozkurt, İ., Karakılçık, M., et al. (2014). Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. Adıyaman University Journal of Educational Sciences, 4(1), 1-10.
AMA Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. AUJES. June 2014;4(1):1-10.
Chicago Bozkurt, İsmail, Ayhan Atız, İsmail Bozkurt, Mehmet Karakılçık, and Mehmet Karakılçık. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Educational Sciences 4, no. 1 (June 2014): 1-10.
EndNote Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M (June 1, 2014) Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. Adıyaman University Journal of Educational Sciences 4 1 1–10.
IEEE İ. Bozkurt, A. Atız, İ. Bozkurt, M. Karakılçık, and M. Karakılçık, “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”, AUJES, vol. 4, no. 1, pp. 1–10, 2014.
ISNAD Bozkurt, İsmail et al. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Educational Sciences 4/1 (June 2014), 1-10.
JAMA Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. AUJES. 2014;4:1–10.
MLA Bozkurt, İsmail et al. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Educational Sciences, vol. 4, no. 1, 2014, pp. 1-10.
Vancouver Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. AUJES. 2014;4(1):1-10.

 Content of this journal is licensed under a Creative Commons Attribution NonCommercial 4.0 International License