Measurement methods of femoral torsion in CDH (comparison of four methods in patients)

Volume: 26 Number: 3 September 11, 2006
  • Nihat Tosun
  • M. Avkan
  • Adnan Okur
  • Bulent Alparslan
  • Ali Okur
TR EN

Measurement methods of femoral torsion in CDH (comparison of four methods in patients)

Abstract

In this study, femoral torsion degrees of 23 patients who have CDH were measured by Magilligan, König Schult and Reynolds biplanar methods and the results were compared with the results of CT in Atatürk University Medical Faculty Orthopaedics and Traumatology Clinic between May 1990 and July 1991. The results of König-Schult method were close to the results of CT. The results of Magilligan and Reynolds methods were different from the other ones.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Nihat Tosun This is me

M. Avkan This is me

Adnan Okur This is me

Bulent Alparslan This is me

Ali Okur This is me

Publication Date

September 11, 2006

Submission Date

March 6, 2014

Acceptance Date

-

Published in Issue

Year 1992 Volume: 26 Number: 3

APA
Tosun, N., Avkan, M., Okur, A., Alparslan, B., & Okur, A. (2006). Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica, 26(3), 176-178. https://doi.org/10.3944/aott.v26i3.1331
AMA
1.Tosun N, Avkan M, Okur A, Alparslan B, Okur A. Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica. 2006;26(3):176-178. doi:10.3944/aott.v26i3.1331
Chicago
Tosun, Nihat, M. Avkan, Adnan Okur, Bulent Alparslan, and Ali Okur. 2006. “Measurement Methods of Femoral Torsion in CDH (comparison of Four Methods in Patients)”. Acta Orthopaedica et Traumatologica Turcica 26 (3): 176-78. https://doi.org/10.3944/aott.v26i3.1331.
EndNote
Tosun N, Avkan M, Okur A, Alparslan B, Okur A (September 1, 2006) Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica 26 3 176–178.
IEEE
[1]N. Tosun, M. Avkan, A. Okur, B. Alparslan, and A. Okur, “Measurement methods of femoral torsion in CDH (comparison of four methods in patients)”, Acta Orthopaedica et Traumatologica Turcica, vol. 26, no. 3, pp. 176–178, Sept. 2006, doi: 10.3944/aott.v26i3.1331.
ISNAD
Tosun, Nihat - Avkan, M. - Okur, Adnan - Alparslan, Bulent - Okur, Ali. “Measurement Methods of Femoral Torsion in CDH (comparison of Four Methods in Patients)”. Acta Orthopaedica et Traumatologica Turcica 26/3 (September 1, 2006): 176-178. https://doi.org/10.3944/aott.v26i3.1331.
JAMA
1.Tosun N, Avkan M, Okur A, Alparslan B, Okur A. Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica. 2006;26:176–178.
MLA
Tosun, Nihat, et al. “Measurement Methods of Femoral Torsion in CDH (comparison of Four Methods in Patients)”. Acta Orthopaedica et Traumatologica Turcica, vol. 26, no. 3, Sept. 2006, pp. 176-8, doi:10.3944/aott.v26i3.1331.
Vancouver
1.Nihat Tosun, M. Avkan, Adnan Okur, Bulent Alparslan, Ali Okur. Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica. 2006 Sep. 1;26(3):176-8. doi:10.3944/aott.v26i3.1331