Measurement methods of femoral torsion in CDH (comparison of four methods in patients)

Cilt: 26 Sayı: 3 11 Eylül 2006
  • Nihat Tosun
  • M. Avkan
  • Adnan Okur
  • Bulent Alparslan
  • Ali Okur
PDF İndir
TR EN

Measurement methods of femoral torsion in CDH (comparison of four methods in patients)

Öz

In this study, femoral torsion degrees of 23 patients who have CDH were measured by Magilligan, König Schult and Reynolds biplanar methods and the results were compared with the results of CT in Atatürk University Medical Faculty Orthopaedics and Traumatology Clinic between May 1990 and July 1991. The results of König-Schult method were close to the results of CT. The results of Magilligan and Reynolds methods were different from the other ones.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Nihat Tosun Bu kişi benim

Adnan Okur Bu kişi benim

Bulent Alparslan Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1992 Cilt: 26 Sayı: 3

Kaynak Göster

APA
Tosun, N., Avkan, M., Okur, A., Alparslan, B., & Okur, A. (2006). Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica, 26(3), 176-178. https://doi.org/10.3944/aott.v26i3.1331
AMA
1.Tosun N, Avkan M, Okur A, Alparslan B, Okur A. Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica. 2006;26(3):176-178. doi:10.3944/aott.v26i3.1331
Chicago
Tosun, Nihat, M. Avkan, Adnan Okur, Bulent Alparslan, ve Ali Okur. 2006. “Measurement methods of femoral torsion in CDH (comparison of four methods in patients)”. Acta Orthopaedica et Traumatologica Turcica 26 (3): 176-78. https://doi.org/10.3944/aott.v26i3.1331.
EndNote
Tosun N, Avkan M, Okur A, Alparslan B, Okur A (01 Eylül 2006) Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica 26 3 176–178.
IEEE
[1]N. Tosun, M. Avkan, A. Okur, B. Alparslan, ve A. Okur, “Measurement methods of femoral torsion in CDH (comparison of four methods in patients)”, Acta Orthopaedica et Traumatologica Turcica, c. 26, sy 3, ss. 176–178, Eyl. 2006, doi: 10.3944/aott.v26i3.1331.
ISNAD
Tosun, Nihat - Avkan, M. - Okur, Adnan - Alparslan, Bulent - Okur, Ali. “Measurement methods of femoral torsion in CDH (comparison of four methods in patients)”. Acta Orthopaedica et Traumatologica Turcica 26/3 (01 Eylül 2006): 176-178. https://doi.org/10.3944/aott.v26i3.1331.
JAMA
1.Tosun N, Avkan M, Okur A, Alparslan B, Okur A. Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica. 2006;26:176–178.
MLA
Tosun, Nihat, vd. “Measurement methods of femoral torsion in CDH (comparison of four methods in patients)”. Acta Orthopaedica et Traumatologica Turcica, c. 26, sy 3, Eylül 2006, ss. 176-8, doi:10.3944/aott.v26i3.1331.
Vancouver
1.Nihat Tosun, M. Avkan, Adnan Okur, Bulent Alparslan, Ali Okur. Measurement methods of femoral torsion in CDH (comparison of four methods in patients). Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;26(3):176-8. doi:10.3944/aott.v26i3.1331