Abstract

Axial loading produces compression force on medial cortex and tension on lateral cortex at femoral fractures fixed by plate. The wave in the plate could have an adverse effect by increasing the moment arm, but lateral cortex would support the compressive force. Wave plate would allow grafting on lateral cortex and also preserve blood supply. This experimental study is designed to search primary stability of wave plate. Defected fractures on twenty sheep’s femurs were fixed with wave plate on the right and with standard small fragment plate on the left. Five mm. wave was made on ten right femurs and ten mm. wave was made on the other ten right femurs. Accelerated axial loading was applied to all femurs and the results were recorded. Loading which closed the defect was accepted as primary loading value (F1) and also loading which deformed the plate screw complex was accepted as maximum loading value (F2). There were not any significant differences between 5 mm. wave plate and standard plate on F1 and F2. Ten mm. wave plate was less stable than standard plate on primary loading value (F1) but stable on maximum loading value (F2). We concluded that the wave plate application is stable while wave’s height is 1/3 diameter of femoral shaft as standard plate. Higher waves would decrease the primary stability of the wave plate.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Emre Cullu This is me

İlhan Ozkan This is me

Sami Aksoy This is me

Bulent Alparslan This is me

Publication Date

September 11, 2006

Submission Date

March 6, 2014

Acceptance Date

-

Published in Issue

Year 1999 Volume: 33 Number: 2

APA
Cullu, E., Ozkan, İ., Aksoy, S., & Alparslan, B. (2006). Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica, 33(2), 147-150. https://doi.org/10.3944/aott.v33i2.2321
AMA
1.Cullu E, Ozkan İ, Aksoy S, Alparslan B. Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica. 2006;33(2):147-150. doi:10.3944/aott.v33i2.2321
Chicago
Cullu, Emre, İlhan Ozkan, Sami Aksoy, and Bulent Alparslan. 2006. “Primary Stability of Wave Plate (Experimental Study)”. Acta Orthopaedica et Traumatologica Turcica 33 (2): 147-50. https://doi.org/10.3944/aott.v33i2.2321.
EndNote
Cullu E, Ozkan İ, Aksoy S, Alparslan B (September 1, 2006) Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica 33 2 147–150.
IEEE
[1]E. Cullu, İ. Ozkan, S. Aksoy, and B. Alparslan, “Primary stability of wave plate (Experimental study)”, Acta Orthopaedica et Traumatologica Turcica, vol. 33, no. 2, pp. 147–150, Sept. 2006, doi: 10.3944/aott.v33i2.2321.
ISNAD
Cullu, Emre - Ozkan, İlhan - Aksoy, Sami - Alparslan, Bulent. “Primary Stability of Wave Plate (Experimental Study)”. Acta Orthopaedica et Traumatologica Turcica 33/2 (September 1, 2006): 147-150. https://doi.org/10.3944/aott.v33i2.2321.
JAMA
1.Cullu E, Ozkan İ, Aksoy S, Alparslan B. Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica. 2006;33:147–150.
MLA
Cullu, Emre, et al. “Primary Stability of Wave Plate (Experimental Study)”. Acta Orthopaedica et Traumatologica Turcica, vol. 33, no. 2, Sept. 2006, pp. 147-50, doi:10.3944/aott.v33i2.2321.
Vancouver
1.Emre Cullu, İlhan Ozkan, Sami Aksoy, Bulent Alparslan. Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica. 2006 Sep. 1;33(2):147-50. doi:10.3944/aott.v33i2.2321