Primary stability of wave plate (Experimental study)

Cilt: 33 Sayı: 2 11 Eylül 2006
  • Emre Cullu
  • İlhan Ozkan
  • Sami Aksoy
  • Bulent Alparslan
PDF İndir
EN TR

Primary stability of wave plate (Experimental study)

Abstract

Axial loading produces compression force on medial cortex and tension on lateral cortex at femoral fractures fixed by plate. The wave in the plate could have an adverse effect by increasing the moment arm, but lateral cortex would support the compressive force. Wave plate would allow grafting on lateral cortex and also preserve blood supply. This experimental study is designed to search primary stability of wave plate. Defected fractures on twenty sheep’s femurs were fixed with wave plate on the right and with standard small fragment plate on the left. Five mm. wave was made on ten right femurs and ten mm. wave was made on the other ten right femurs. Accelerated axial loading was applied to all femurs and the results were recorded. Loading which closed the defect was accepted as primary loading value (F1) and also loading which deformed the plate screw complex was accepted as maximum loading value (F2). There were not any significant differences between 5 mm. wave plate and standard plate on F1 and F2. Ten mm. wave plate was less stable than standard plate on primary loading value (F1) but stable on maximum loading value (F2). We concluded that the wave plate application is stable while wave’s height is 1/3 diameter of femoral shaft as standard plate. Higher waves would decrease the primary stability of the wave plate.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Emre Cullu Bu kişi benim

İlhan Ozkan Bu kişi benim

Sami Aksoy Bu kişi benim

Bulent Alparslan Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1999 Cilt: 33 Sayı: 2

Kaynak Göster

APA
Cullu, E., Ozkan, İ., Aksoy, S., & Alparslan, B. (2006). Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica, 33(2), 147-150. https://doi.org/10.3944/aott.v33i2.2321
AMA
1.Cullu E, Ozkan İ, Aksoy S, Alparslan B. Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica. 2006;33(2):147-150. doi:10.3944/aott.v33i2.2321
Chicago
Cullu, Emre, İlhan Ozkan, Sami Aksoy, ve Bulent Alparslan. 2006. “Primary stability of wave plate (Experimental study)”. Acta Orthopaedica et Traumatologica Turcica 33 (2): 147-50. https://doi.org/10.3944/aott.v33i2.2321.
EndNote
Cullu E, Ozkan İ, Aksoy S, Alparslan B (01 Eylül 2006) Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica 33 2 147–150.
IEEE
[1]E. Cullu, İ. Ozkan, S. Aksoy, ve B. Alparslan, “Primary stability of wave plate (Experimental study)”, Acta Orthopaedica et Traumatologica Turcica, c. 33, sy 2, ss. 147–150, Eyl. 2006, doi: 10.3944/aott.v33i2.2321.
ISNAD
Cullu, Emre - Ozkan, İlhan - Aksoy, Sami - Alparslan, Bulent. “Primary stability of wave plate (Experimental study)”. Acta Orthopaedica et Traumatologica Turcica 33/2 (01 Eylül 2006): 147-150. https://doi.org/10.3944/aott.v33i2.2321.
JAMA
1.Cullu E, Ozkan İ, Aksoy S, Alparslan B. Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica. 2006;33:147–150.
MLA
Cullu, Emre, vd. “Primary stability of wave plate (Experimental study)”. Acta Orthopaedica et Traumatologica Turcica, c. 33, sy 2, Eylül 2006, ss. 147-50, doi:10.3944/aott.v33i2.2321.
Vancouver
1.Emre Cullu, İlhan Ozkan, Sami Aksoy, Bulent Alparslan. Primary stability of wave plate (Experimental study). Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;33(2):147-50. doi:10.3944/aott.v33i2.2321