Abstract

The use of bioabsorbable meniscus repair devices is becoming more frequent because of their easy and quick application and reduced risk of neurovascular complications. We present three patients who had symptoms mimicking meniscus tears following meniscal repair with the use of the Biostinger bioabsorbable device. Second-look arthroscopies of all cases showed that some of the repair devices were not resorbed despite meniscal healing. Early recovery of symptoms was achieved after the removal of unabsorbed remnants. Prolonged resorption of bioabsorbable meniscus materials may cause intraarticular problems like synovitis and chondral lesions, which should be taken into consideration by meniscal implant designers and researchers.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Mehmet Asik This is me

Ata Atalar This is me

Mursel Debre This is me

Cengiz Sen This is me

Publication Date

September 11, 2006

Submission Date

March 6, 2014

Acceptance Date

-

Published in Issue

Year 2001 Volume: 35 Number: 5

APA
Asik, M., Atalar, A., Debre, M., & Sen, C. (2006). Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica, 35(5), 442-447. https://doi.org/10.3944/aott.v35i5.941
AMA
1.Asik M, Atalar A, Debre M, Sen C. Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica. 2006;35(5):442-447. doi:10.3944/aott.v35i5.941
Chicago
Asik, Mehmet, Ata Atalar, Mursel Debre, and Cengiz Sen. 2006. “Problems Associated With Late Resorption of Bioabsorbable Meniscus Repair Devices”. Acta Orthopaedica et Traumatologica Turcica 35 (5): 442-47. https://doi.org/10.3944/aott.v35i5.941.
EndNote
Asik M, Atalar A, Debre M, Sen C (September 1, 2006) Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica 35 5 442–447.
IEEE
[1]M. Asik, A. Atalar, M. Debre, and C. Sen, “Problems associated with late resorption of bioabsorbable meniscus repair devices”, Acta Orthopaedica et Traumatologica Turcica, vol. 35, no. 5, pp. 442–447, Sept. 2006, doi: 10.3944/aott.v35i5.941.
ISNAD
Asik, Mehmet - Atalar, Ata - Debre, Mursel - Sen, Cengiz. “Problems Associated With Late Resorption of Bioabsorbable Meniscus Repair Devices”. Acta Orthopaedica et Traumatologica Turcica 35/5 (September 1, 2006): 442-447. https://doi.org/10.3944/aott.v35i5.941.
JAMA
1.Asik M, Atalar A, Debre M, Sen C. Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica. 2006;35:442–447.
MLA
Asik, Mehmet, et al. “Problems Associated With Late Resorption of Bioabsorbable Meniscus Repair Devices”. Acta Orthopaedica et Traumatologica Turcica, vol. 35, no. 5, Sept. 2006, pp. 442-7, doi:10.3944/aott.v35i5.941.
Vancouver
1.Mehmet Asik, Ata Atalar, Mursel Debre, Cengiz Sen. Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica. 2006 Sep. 1;35(5):442-7. doi:10.3944/aott.v35i5.941