Problems associated with late resorption of bioabsorbable meniscus repair devices

Cilt: 35 Sayı: 5 11 Eylül 2006
  • Mehmet Asik
  • Ata Atalar
  • Mursel Debre
  • Cengiz Sen
PDF İndir
EN TR

Problems associated with late resorption of bioabsorbable meniscus repair devices

Abstract

The use of bioabsorbable meniscus repair devices is becoming more frequent because of their easy and quick application and reduced risk of neurovascular complications. We present three patients who had symptoms mimicking meniscus tears following meniscal repair with the use of the Biostinger bioabsorbable device. Second-look arthroscopies of all cases showed that some of the repair devices were not resorbed despite meniscal healing. Early recovery of symptoms was achieved after the removal of unabsorbed remnants. Prolonged resorption of bioabsorbable meniscus materials may cause intraarticular problems like synovitis and chondral lesions, which should be taken into consideration by meniscal implant designers and researchers.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Mehmet Asik Bu kişi benim

Ata Atalar Bu kişi benim

Mursel Debre Bu kişi benim

Cengiz Sen Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2001 Cilt: 35 Sayı: 5

Kaynak Göster

APA
Asik, M., Atalar, A., Debre, M., & Sen, C. (2006). Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica, 35(5), 442-447. https://doi.org/10.3944/aott.v35i5.941
AMA
1.Asik M, Atalar A, Debre M, Sen C. Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica. 2006;35(5):442-447. doi:10.3944/aott.v35i5.941
Chicago
Asik, Mehmet, Ata Atalar, Mursel Debre, ve Cengiz Sen. 2006. “Problems associated with late resorption of bioabsorbable meniscus repair devices”. Acta Orthopaedica et Traumatologica Turcica 35 (5): 442-47. https://doi.org/10.3944/aott.v35i5.941.
EndNote
Asik M, Atalar A, Debre M, Sen C (01 Eylül 2006) Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica 35 5 442–447.
IEEE
[1]M. Asik, A. Atalar, M. Debre, ve C. Sen, “Problems associated with late resorption of bioabsorbable meniscus repair devices”, Acta Orthopaedica et Traumatologica Turcica, c. 35, sy 5, ss. 442–447, Eyl. 2006, doi: 10.3944/aott.v35i5.941.
ISNAD
Asik, Mehmet - Atalar, Ata - Debre, Mursel - Sen, Cengiz. “Problems associated with late resorption of bioabsorbable meniscus repair devices”. Acta Orthopaedica et Traumatologica Turcica 35/5 (01 Eylül 2006): 442-447. https://doi.org/10.3944/aott.v35i5.941.
JAMA
1.Asik M, Atalar A, Debre M, Sen C. Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica. 2006;35:442–447.
MLA
Asik, Mehmet, vd. “Problems associated with late resorption of bioabsorbable meniscus repair devices”. Acta Orthopaedica et Traumatologica Turcica, c. 35, sy 5, Eylül 2006, ss. 442-7, doi:10.3944/aott.v35i5.941.
Vancouver
1.Mehmet Asik, Ata Atalar, Mursel Debre, Cengiz Sen. Problems associated with late resorption of bioabsorbable meniscus repair devices. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;35(5):442-7. doi:10.3944/aott.v35i5.941