False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture

Volume: 14 Number: 4 November 21, 1980
  • Sukru Arac
  • Yaser Musdal
EN TR

False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture

Abstract

A case of false aneurysm of the profunda femoris artery caused by an excessively long screw used to fix a CHS-plate to the neck of the femur is presented. The aneurysm did not become symptomatic until 20 days after insertion of the screw if painful pulsating mass appears in the upper part of the thigh after an operation about the hip in which drills ond screw were used, one should suspect a false aneurysm.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Sukru Arac This is me

Yaser Musdal This is me

Publication Date

November 21, 1980

Submission Date

March 7, 2014

Acceptance Date

-

Published in Issue

Year 1980 Volume: 14 Number: 4

APA
Arac, S., & Musdal, Y. (1980). False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica, 14(4), 195-199. https://doi.org/10.3944/aott.v14i4.3229
AMA
1.Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14(4):195-199. doi:10.3944/aott.v14i4.3229
Chicago
Arac, Sukru, and Yaser Musdal. 1980. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica et Traumatologica Turcica 14 (4): 195-99. https://doi.org/10.3944/aott.v14i4.3229.
EndNote
Arac S, Musdal Y (November 1, 1980) False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica 14 4 195–199.
IEEE
[1]S. Arac and Y. Musdal, “False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture”, Acta Orthopaedica et Traumatologica Turcica, vol. 14, no. 4, pp. 195–199, Nov. 1980, doi: 10.3944/aott.v14i4.3229.
ISNAD
Arac, Sukru - Musdal, Yaser. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica et Traumatologica Turcica 14/4 (November 1, 1980): 195-199. https://doi.org/10.3944/aott.v14i4.3229.
JAMA
1.Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14:195–199.
MLA
Arac, Sukru, and Yaser Musdal. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica et Traumatologica Turcica, vol. 14, no. 4, Nov. 1980, pp. 195-9, doi:10.3944/aott.v14i4.3229.
Vancouver
1.Sukru Arac, Yaser Musdal. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980 Nov. 1;14(4):195-9. doi:10.3944/aott.v14i4.3229