A case of false aneurysm of the profunda femoris artery caused by an excessively long screw used to fix a CHS-plate to the neck of the femur is presented. The aneurysm did not become symptomatic until 20 days after insertion of the screw if painful pulsating mass appears in the upper part of the thigh after an operation about the hip in which drills ond screw were used, one should suspect a false aneurysm.
Keywords
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
-
Yayımlanma Tarihi
21 Kasım 1980
Gönderilme Tarihi
7 Mart 2014
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 1980 Cilt: 14 Sayı: 4
APA
Arac, S., & Musdal, Y. (1980). False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica, 14(4), 195-199. https://doi.org/10.3944/aott.v14i4.3229
AMA
1.Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14(4):195-199. doi:10.3944/aott.v14i4.3229
Chicago
Arac, Sukru, ve Yaser Musdal. 1980. “False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture”. Acta Orthopaedica et Traumatologica Turcica 14 (4): 195-99. https://doi.org/10.3944/aott.v14i4.3229.
EndNote
Arac S, Musdal Y (01 Kasım 1980) False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica 14 4 195–199.
IEEE
[1]S. Arac ve Y. Musdal, “False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture”, Acta Orthopaedica et Traumatologica Turcica, c. 14, sy 4, ss. 195–199, Kas. 1980, doi: 10.3944/aott.v14i4.3229.
ISNAD
Arac, Sukru - Musdal, Yaser. “False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture”. Acta Orthopaedica et Traumatologica Turcica 14/4 (01 Kasım 1980): 195-199. https://doi.org/10.3944/aott.v14i4.3229.
JAMA
1.Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14:195–199.
MLA
Arac, Sukru, ve Yaser Musdal. “False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture”. Acta Orthopaedica et Traumatologica Turcica, c. 14, sy 4, Kasım 1980, ss. 195-9, doi:10.3944/aott.v14i4.3229.
Vancouver
1.Sukru Arac, Yaser Musdal. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 01 Kasım 1980;14(4):195-9. doi:10.3944/aott.v14i4.3229