Abstract

Objective: The aim of our study was to compare the biomechanical properties of different fixation methods used in periprosthetic femur fractures.
Methods: We created sawbone models with Mallory Type 2 periprosthetic femur fractures. The periprosthetic fractures were fixed with cables, cables and strut graft, or cables and plates. The biomechanical properties of these three different fixation methods were compared with the intact femur, the intact femur with prosthesis and the femur with periprosthetic fracture without fixation.
Results: The periprosthetic fracture without fixation had a significantly lower yield point value than the periprosthetic fractures with fixation (p<0.05). There was no significant difference between the three different fixation methods of the periprosthetic fractures. The intact femur with a prosthesis showed statistically higher values than all three fixation methods of perioprosthetic fractures.
Conclusion: Mallory Type 2 periprosthetic fractures should be fixed. There is no difference among the fixation methods used in the study and none of them provide a stability equivalent to that of an intact femur with prosthesis. 

Keywords

Details

Primary Language

English

Subjects

Health Care Administration

Journal Section

Research Article

Authors

Mehmet Gulsen This is me

Vasfi Karatosun This is me

Bahadır Uyulgan This is me

Publication Date

September 14, 2011

Submission Date

March 7, 2014

Acceptance Date

-

Published in Issue

Year 2011 Volume: 45 Number: 4

APA
Gulsen, M., Karatosun, V., & Uyulgan, B. (2011). The biomechanical assessment of fixation methods in periprosthetic femur fractures. Acta Orthopaedica et Traumatologica Turcica, 45(4), 266-269. https://izlik.org/JA25JN57EH
AMA
1.Gulsen M, Karatosun V, Uyulgan B. The biomechanical assessment of fixation methods in periprosthetic femur fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;45(4):266-269. https://izlik.org/JA25JN57EH
Chicago
Gulsen, Mehmet, Vasfi Karatosun, and Bahadır Uyulgan. 2011. “The Biomechanical Assessment of Fixation Methods in Periprosthetic Femur Fractures”. Acta Orthopaedica et Traumatologica Turcica 45 (4): 266-69. https://izlik.org/JA25JN57EH.
EndNote
Gulsen M, Karatosun V, Uyulgan B (September 1, 2011) The biomechanical assessment of fixation methods in periprosthetic femur fractures. Acta Orthopaedica et Traumatologica Turcica 45 4 266–269.
IEEE
[1]M. Gulsen, V. Karatosun, and B. Uyulgan, “The biomechanical assessment of fixation methods in periprosthetic femur fractures”, Acta Orthopaedica et Traumatologica Turcica, vol. 45, no. 4, pp. 266–269, Sept. 2011, [Online]. Available: https://izlik.org/JA25JN57EH
ISNAD
Gulsen, Mehmet - Karatosun, Vasfi - Uyulgan, Bahadır. “The Biomechanical Assessment of Fixation Methods in Periprosthetic Femur Fractures”. Acta Orthopaedica et Traumatologica Turcica 45/4 (September 1, 2011): 266-269. https://izlik.org/JA25JN57EH.
JAMA
1.Gulsen M, Karatosun V, Uyulgan B. The biomechanical assessment of fixation methods in periprosthetic femur fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;45:266–269.
MLA
Gulsen, Mehmet, et al. “The Biomechanical Assessment of Fixation Methods in Periprosthetic Femur Fractures”. Acta Orthopaedica et Traumatologica Turcica, vol. 45, no. 4, Sept. 2011, pp. 266-9, https://izlik.org/JA25JN57EH.
Vancouver
1.Mehmet Gulsen, Vasfi Karatosun, Bahadır Uyulgan. The biomechanical assessment of fixation methods in periprosthetic femur fractures. Acta Orthopaedica et Traumatologica Turcica [Internet]. 2011 Sep. 1;45(4):266-9. Available from: https://izlik.org/JA25JN57EH