TR
EN
Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor
Abstract
The aim of this study is to evaluate both dynamic thiol-disulfide and ischemia modified albumin (IMA) levels in cord blood of newborns to patients with oxytocin-induced labor. A total of 30 pregnant women who underwent medical labor induction with oxytocin were compared with 30 women whose labor progressed spontaneously without any kind of induction. The dynamic thiol-disulfide balance was determined by the new colorimetric method developed by Erel et al. IMA levels were analyzed by using albumin cobalt binding test developed by Bar-Or et al. It was found that TAS and OSI levels were higher and TOS levels were lower in the oxytocin-induced group compared to the controls. Native and total thiol levels were found lower while disulfide levels were found higher oxytocin-induced group respect to the control. IMA levels were found significantly different between the patient and control subjects. We indicate that formation of disulfide leads to decrease antioxidant capacity in newborns of oxytocin-induced patients. Dynamic thiol-disulfide homeostasis may contribute to the monitoring of oxidative stress in infants of oxytocin-induced patients and the follow-up of diseases that may arise due to oxidative stress.
Keywords
Kaynakça
- Alchalabi, H. A., Obeidat, B. R., Jallad, M. F., & Khader, Y. S. (2006). Induction of labor and perinatal outcome: the impact of the amniotic fluid index. Eur J Obstet Gynecol Reprod Biol, 129(2), 124-127. doi: 10.1016/j.ejogrb.2005.10.039
- Bar-Or, D., Curtis, G., Rao, N., Bampos, N., & Lau, E. (2001). Characterization of the Co(2+) and Ni(2+) binding amino-acid residues of the N-terminus of human albumin. An insight into the mechanism of a new assay for myocardial ischemia. Eur J Biochem, 268(1), 42-47. doi: 10.1046/j.1432-1327.2001.01846.x
- Cakirca, G., C. M., Erdal H, Neselioglu S, Erel O, Basarali MK, Cakirca TD. (2018). Investigation of thiol/disulfide homeostasis in familial mediterranean fever patients. Clin Anal Med, 9(3), 231-234. doi: 10.4328/JCAM.5789
- Demirtas, M.S., Erdal H . Evaluation of thiol-disulfide homeostasis and oxidative stress parameters in newborns receiving photheraphy. J Investig Med. doi: 10.1177/jim-10815589221140594
- Demirtas, M. S., Erdal H (2022) Evaluation of Thiol Disulfide Balance in Adolescents With Vitamin B12 Deficiency. DOI: https://doi.org/10.21203/rs.3.rs-1318028/v1
- Erdal, H., Özcan, O., Turgut, F., Neşelioğlu, S., Erel Ö. (2022). Evaluation of dynamic thiol-disulfide balance and ischemia modified albumin levels in patients with chronic kidney disease. MKÜ Tıp Dergisi. 2022;13(47):237-242. https://doi.org/10.17944/mkutfd.947113
- Erdal, H., Ciftciler, R., Tuncer, S. C., Ozcan, O. (2022). Evaluation of dynamic thiol-disulfide homeostasis and ischemia-modified albumin levels in patients with chronic lymphocytic leukemia. J Investig Med. doi: 10.1136/jim-2022-002568
- Erdal, H., Demirtas, M. S., Tuncer, S.C., Ozcan O (2022).Thiol/disulfide homeostasis as a new oxidative stress marker in patients with neonatal transient tachypnea. Ann Clin Anal Med 2022, doi: 10.4328/ACAM.21457
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Klinik Araştırma
Yayımlanma Tarihi
29 Aralık 2022
Gönderilme Tarihi
12 Kasım 2022
Kabul Tarihi
7 Aralık 2022
Yayımlandığı Sayı
Yıl 2022 Cilt: 3 Sayı: 2
APA
Erdal, H., & Bekmezci, M. (2022). Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor. Aksaray University Journal of Sport and Health Researches, 3(2), 193-202. https://doi.org/10.54152/asujshr.1203106
AMA
1.Erdal H, Bekmezci M. Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor. ASUJSHR. 2022;3(2):193-202. doi:10.54152/asujshr.1203106
Chicago
Erdal, Hüseyin, ve Meryem Bekmezci. 2022. “Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor”. Aksaray University Journal of Sport and Health Researches 3 (2): 193-202. https://doi.org/10.54152/asujshr.1203106.
EndNote
Erdal H, Bekmezci M (01 Aralık 2022) Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor. Aksaray University Journal of Sport and Health Researches 3 2 193–202.
IEEE
[1]H. Erdal ve M. Bekmezci, “Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor”, ASUJSHR, c. 3, sy 2, ss. 193–202, Ara. 2022, doi: 10.54152/asujshr.1203106.
ISNAD
Erdal, Hüseyin - Bekmezci, Meryem. “Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor”. Aksaray University Journal of Sport and Health Researches 3/2 (01 Aralık 2022): 193-202. https://doi.org/10.54152/asujshr.1203106.
JAMA
1.Erdal H, Bekmezci M. Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor. ASUJSHR. 2022;3:193–202.
MLA
Erdal, Hüseyin, ve Meryem Bekmezci. “Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor”. Aksaray University Journal of Sport and Health Researches, c. 3, sy 2, Aralık 2022, ss. 193-02, doi:10.54152/asujshr.1203106.
Vancouver
1.Hüseyin Erdal, Meryem Bekmezci. Evaluation of Dynamic Thiol /Disulfide Homeostasis and Ischemia- Modified-Albumin Levels in Cord Blood of Newborns to Patients with Oxytocin-Induced Labor. ASUJSHR. 01 Aralık 2022;3(2):193-202. doi:10.54152/asujshr.1203106