BibTex RIS Cite

EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER

0 - , 16.06.2015
https://doi.org/10.17567/dfd.45195

Abstract

Aim: The aim of this study was to test apical micro-leakage of n-butyl-2-cyanoacrylate as a root-end filling material by the computerized fluid filtration meter.
Material and methods: Seventy-nine extracted human mandibular premolar teeth with one root canal were selected. The specimens were divided into five groups of 13 teeth each and filled with the AH Plus root canal sealer. After obturation, the roots were resected at 300 angle and filled with a root-end filling material. The sealing qualities of the five different root-end filling materials were measured using computerized fluid filtration method.

Results: The mean values of apical micro-leakage were 5.0±1.07x10-4, 4.0±1.5x10-4, 4.0±2.2x10-4, 1.0±0.6x10-4,and 4.0±1.1x10-4 µl.cmH2O-1.min-1 at 120 kPa, in groups 1 to 5, respectively. The statistically significant differences were not found among the retrofilling materials (P>0.05).

Conclusion: This type of cyanoacrylate has been used firstly as retrograde filling material. Tissue Adhesive can be used as a root-end filling material in apical surgery.

Keywords: Tissue adhesive; root-end filling materials; apical micro-leakage, computerized fluid filtration meter.

Özet

Amaç: Bu çalışmanın amacı, kök ucu dolgu maddesi olarak kullanılan n-butyl-2-cyanoacrylate’ın bilgisayarlı sıvı filtrasyon metresi ile apikal mikro-sızıntısının test edilmesidir.

Gereç ve Yöntemler: 79 adet çekilmiş tek kök kanallı insan mandibular premolar diş seçildi.

Örnekler her grupta 13 diş olacak şekilde beş gruba ayrıldı ve AH Plus kanal patı kullanılarak kök kanalları dolduruldu. Obturasyondan sonra, kökler 300 açı ile rezeke edildi ve kök ucu dolguları kök ucu dolgu materyalleri ile yapıldı. Beş farklı kök ucu dolgu materyalinin sızdırmazlık dereceleri bilgisayarlı sıvı filtrasyon metodu kullanılarak ölçüldü.

Bulgular: Apikal mikro-sızıntı ortalama değerleri, 120 kPa’da grup 1’den 5’e sırası ile 5.0±1.07x10-4, 4.0±1.5x10-4, 4.0±2.2x10-4, 1.0±0.6x10-4 ve 4.0±1.1x10-4 µl.cmH2O-1.min-1’dir. İstatistiksel olarak kök ucu dolgu materyalleri arasında anlamlı farlılık gözlenmedi (P>0.05).

Sonuç: Bu tip cyanoacrylate ilk defa kök ucu dolu materyali olarak kullanıldı. Doku adezivi apikal cerrahide kök ucu dolgu materyali olarak kullanılabilir.

Anahtar Kelimeler: Doku adezivi, kök ucu dolu materyali, apikal mikro-sızıntı, bilgisayarlı sıvı filtrasyon metresi.

0 - , 16.06.2015
https://doi.org/10.17567/dfd.45195

Abstract

There are 0 citations in total.

Details

Primary Language English
Journal Section Articles
Authors

Ersan Çiçek This is me

Semih Özsevık This is me

Murat Cortcu This is me

Hasan Oruçoğlu This is me

Publication Date June 16, 2015
Published in Issue Year 2015

Cite

APA Çiçek, E., Özsevık, S., Cortcu, M., Oruçoğlu, H. (n.d.). EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 25(1). https://doi.org/10.17567/dfd.45195
AMA Çiçek E, Özsevık S, Cortcu M, Oruçoğlu H. EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER. Ata Diş Hek Fak Derg. 25(1). doi:10.17567/dfd.45195
Chicago Çiçek, Ersan, Semih Özsevık, Murat Cortcu, and Hasan Oruçoğlu. “EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 25, no. 1 n.d. https://doi.org/10.17567/dfd.45195.
EndNote Çiçek E, Özsevık S, Cortcu M, Oruçoğlu H EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 25 1
IEEE E. Çiçek, S. Özsevık, M. Cortcu, and H. Oruçoğlu, “EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER”, Ata Diş Hek Fak Derg, vol. 25, no. 1, doi: 10.17567/dfd.45195.
ISNAD Çiçek, Ersan et al. “EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 25/1 (n.d.). https://doi.org/10.17567/dfd.45195.
JAMA Çiçek E, Özsevık S, Cortcu M, Oruçoğlu H. EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER. Ata Diş Hek Fak Derg.;25. doi:10.17567/dfd.45195.
MLA Çiçek, Ersan et al. “EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, vol. 25, no. 1, doi:10.17567/dfd.45195.
Vancouver Çiçek E, Özsevık S, Cortcu M, Oruçoğlu H. EVALUATION OF DIFFERENT ROOT-END FILLING MATERIALS IN POINT OF APICAL MICRO-LEAKAGE BY THE COMPUTERIZED FLUID FILTRATION METER. Ata Diş Hek Fak Derg. 25(1).

Bu eser Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır. Tıklayınız.