BibTex RIS Cite

THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST

Year 2015, Volume: 25 Issue: 3, 0 - 0, 03.05.2016

Abstract

ABSTRACT

 Objectives: The purpose of this in-vitro study was to evaluate the effect of 3-different post-space on the bond strength of fiber post.

Study design: Fifty-four extracted human maxillary incisors were selected and their roots were treated endodontically. The roots were prepared according to different post spaces (Torpan Drill ISO 100(D100), 120(D120) and Enapost Drill ISO 140(D140), and divided into three groups. Snowposts were used, and the posts were cemented with three different dual polymerized resin luting agents: Panavia F, NX3 and Rely X. The specimens were subjected to a pullout test using a universal testing machine at a cross-head speed of 0.5 mm/min. The maximum force required to dislodge each post was recorded. Data were analyzed using the two way ANOVA and Tukey multiple comparisons tests.

Results: According to the results of Tukey test, the bond strength values of the Panavia F luting cements was significantly higher in D120 post space; otherwise, there were no significant differences between Rely X and NX 3.

Conclusions: It had been seen that cement thickness affects the pullout strengths of fiber-reinforced posts.

Key Words: bond strength, cement thickness,  post

FİBER POSTLARIN BAĞLANMA DAYANIMI ÜZERİNDE SİMAN KALINLIĞININ ETKİSİ

ÖZET

 Amaç: Bu çalışmanın amacı fiber postların bağlanma dayanımına 3 farklı post aralığının etkisini değerlendirmektir.

Materyal ve Metod: Çekilmiş 54 adet üst kesici diş kullanıldı ve bu dişlere kök- kanal tedavisi uygulandı. Kök kanalları değişik boyutlarda post boşluklarına göre hazırlandı (Torpan Drill ISO 100(D100), 120(D120) ve Enapost Drill ISO 140(D140),Drill) ve 3 alt gruba ayrıldı. Fiberpostlar (Snowpost) 3 farklı kimyasal ve ışıkla (dual)sertleşen rezin simanla (Panavia F, NX3 and Rely X) simante edildi. Örneklere başlık hızı 0,5 mm/dk olan universal test cihazıyla çekme testi uygulandı. Postları yerinden uzaklaştıran maksimum kuvvetler kayıt edildi. Veriler Two-way ANOVA ve Tukey testleri kullanılarak analiz edildi.

Bulgular: Tukey testi sonuçlarına göre Tropan D120 drill ile açılan post boşluklarında Panavia F ile simante edilen dişlerin değerlerinin en yüksek olduğu, buna rağmen Rely X ve NX3 değerleri arasında istatistiksel olarak önemli bir farklılık olmadığı görülmüştür.

Sonuç: Siman kalınlığının fiberle güçlendirilmiş postların çekme kuvvetini etkilediği görülmüştür.

Anahtar Kelimeler: Bağlanma Dayanımı, Siman Kalınlığı, Post


Year 2015, Volume: 25 Issue: 3, 0 - 0, 03.05.2016

Abstract

There are 0 citations in total.

Details

Journal Section Articles
Authors

Duygu Kürklü This is me

Nuran Dinçkal Yanıkoğlu This is me

Bilal Holoğlu This is me

Publication Date May 3, 2016
Published in Issue Year 2015 Volume: 25 Issue: 3

Cite

APA Kürklü, D., Dinçkal Yanıkoğlu, N., & Holoğlu, B. (2016). THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 25(3). https://doi.org/10.17567/dfd.86148
AMA Kürklü D, Dinçkal Yanıkoğlu N, Holoğlu B. THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST. Ata Diş Hek Fak Derg. May 2016;25(3). doi:10.17567/dfd.86148
Chicago Kürklü, Duygu, Nuran Dinçkal Yanıkoğlu, and Bilal Holoğlu. “THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 25, no. 3 (May 2016). https://doi.org/10.17567/dfd.86148.
EndNote Kürklü D, Dinçkal Yanıkoğlu N, Holoğlu B (May 1, 2016) THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 25 3
IEEE D. Kürklü, N. Dinçkal Yanıkoğlu, and B. Holoğlu, “THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST”, Ata Diş Hek Fak Derg, vol. 25, no. 3, 2016, doi: 10.17567/dfd.86148.
ISNAD Kürklü, Duygu et al. “THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 25/3 (May 2016). https://doi.org/10.17567/dfd.86148.
JAMA Kürklü D, Dinçkal Yanıkoğlu N, Holoğlu B. THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST. Ata Diş Hek Fak Derg. 2016;25. doi:10.17567/dfd.86148.
MLA Kürklü, Duygu et al. “THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, vol. 25, no. 3, 2016, doi:10.17567/dfd.86148.
Vancouver Kürklü D, Dinçkal Yanıkoğlu N, Holoğlu B. THE EFFECT OF CEMENT FILM THICKNESS ON THE BOND STRENGTH OF FIBER POST. Ata Diş Hek Fak Derg. 2016;25(3).

Bu eser Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır. Tıklayınız.