BibTex RIS Cite

DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS

Year 2000, Volume: 2 Issue: 2, 34 - 34, 01.06.2000

Abstract

It is now common to obtain information from two or more detectors
in HPLC simultaneously. Conventionally both DAD-HPLC and LC-MS data
are obtained independently, often using quite different approaches, but there
will be common features in both types of information. However, these will
be distorted, for example, Electrospray MS profiles are typically more noisy
and tailing compared to those from DAD-HPLC due to the different physical
processes of passing from the chromatographic column to the detector. A
method for obtaining and processing both types of data simultaneously is
described. The analysis of isomers with identical molecular weights and
similar elution times is particularly important in the pharmaceutical industry
where small impurities can have a major influence on biological activity.
The approach is illustrated by application to a mixture of 2- and 3-
hydroxypyridine at varying levels of overlap.

Year 2000, Volume: 2 Issue: 2, 34 - 34, 01.06.2000

Abstract

There are 0 citations in total.

Details

Other ID JA22AH93JK
Journal Section Article
Authors

Richard G Brereton This is me

Publication Date June 1, 2000
Submission Date June 1, 2000
Published in Issue Year 2000 Volume: 2 Issue: 2

Cite

APA Brereton, R. G. (2000). DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 2(2), 34-34.
AMA Brereton RG. DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. BAUN Fen. Bil. Enst. Dergisi. June 2000;2(2):34-34.
Chicago Brereton, Richard G. “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2, no. 2 (June 2000): 34-34.
EndNote Brereton RG (June 1, 2000) DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2 2 34–34.
IEEE R. G. Brereton, “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”, BAUN Fen. Bil. Enst. Dergisi, vol. 2, no. 2, pp. 34–34, 2000.
ISNAD Brereton, Richard G. “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2/2 (June 2000), 34-34.
JAMA Brereton RG. DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. BAUN Fen. Bil. Enst. Dergisi. 2000;2:34–34.
MLA Brereton, Richard G. “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, vol. 2, no. 2, 2000, pp. 34-34.
Vancouver Brereton RG. DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. BAUN Fen. Bil. Enst. Dergisi. 2000;2(2):34-.